OSHA Inspection: MARINE & INDUSTRIAL COATINGS LLC

Unprogrammed Related inspection · Health discipline

On , OSHA opened an unprogrammed Related health inspection of MARINE & INDUSTRIAL COATINGS LLC in 3400 SHIPWRIGHT ST., PORTSMOUTH, VA 23703 (NAICS 336611). OSHA activity number 338488638.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Marine & Industrial Coatings LLC — free Get an email when a new federal OSHA severe-injury report for Marine & Industrial Coatings LLC is published. One employer, no account, unsubscribe in one click.
Site address
3400 SHIPWRIGHT ST.
City
PORTSMOUTH
State
VA
ZIP
23703
Mailing
3400 SHIPWRIGHT ST., PORTSMOUTH, VA 23703
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336611
Employees
31
Ownership type
A

3 citations on file for this inspection.

1910.107 C03

Serious Gravity 5 1 instance 15 exposed
Issued
Mar 4, 2013
Penalty
Initial $2,380 · Current $1,428 Reduced
29 CFR 1910.107(c)(3):     Hot surfaces were located in spraying area(s) where deposits of combustible residues could readily accumulate:      a.)  Marine and Industrial Coatings, East Coast Repair and Fabrication, Spray Quonset Hut:  On or about 01/15/13, two Heat Wagon Space Heaters were located in a spray area where deposits of flammable and combustible paints accumulate.
Recent events (2)
  • — I (S) $1428
  • — Z (S) $2380

1910.107 C05

Serious Gravity 5 1 instance 15 exposed
Issued
Mar 4, 2013
Abate by
Apr 6, 2013
Penalty
Initial $2,380 · Current $1,428 Reduced
29 CFR 1910.107(c)(5):     Electrical Equipment not approved for locations containing both deposits of readily ignitable residues and explosive vapors was present in spraying area(s):      a.)  Marine and Industrial Coatings, East Coast Repair and Fabrication, Spraying Quonset Hut:  On or about 01/15/13, the electrical outlets located in the spraying area were not approved for the hazardous location.
Recent events (2)
  • — I (S) $1428
  • — Z (S) $2380

1910.303 G02 I

Serious Gravity 5 1 instance 15 exposed
Issued
Mar 4, 2013
Abate by
May 6, 2013
Penalty
Initial $3,570 · Current $2,142 Reduced
29 CFR 1910.303(g)(2)(i):     Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):      a.)  Marine and Industrial Coatings, East Coast Repair and Fabrication, Spraying Quonset Hut:  On or about 01/15/13, employees were exposed to the live electrical conductors of the extension cord powering the Heat Wagon.