NORTH PROVIDENCE, RI —
OSHA Inspection: ARO-SAC, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ARO-SAC, INC. in 1 WARREN AVENUE, NORTH PROVIDENCE, RI 02911 (NAICS 339910). OSHA activity number 338495658.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ARO-SAC, INC.
- Site address
- 1 WARREN AVENUE
- City
- NORTH PROVIDENCE
- State
- RI
- ZIP
- 02911
- Mailing
- 1 WARREN AVENUE, NORTH PROVIDENCE, RI 02911
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 339910
- Employees
- 15
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.219 C02 I
- Issued
- Feb 14, 2013
- Abate by
- Mar 11, 2013
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: (a) Polishing area: The horizontal shafts of the Gesswein polishing machines were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting, on or about 1-28-13.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1910.303 B02
- Issued
- Feb 14, 2013
- Abate by
- Mar 4, 2013
- Penalty
- Initial $1,600 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: (a) Truck Maintenance Shop: The Universal 6 outlet Relocatable Power Tap (power strip) that was in use powering a light fixture was not installed in accordance with instructions from the manufacturer and included in the listing and labeling, UL 1363, in that they were used as a substitute for fixed wiring, on or about 1-28-13.
Recent events (2)
- — I (O) $0
- — Z (S) $1600
More inspections at Aro-Sac, INC.
View Aro-Sac, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 339910)
More inspections in RI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338495658.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.