Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MCINTOSH INDUSTRIES INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of MCINTOSH INDUSTRIES INC. in 676 RAMSEY AVENUE, HILLSIDE, NJ 07205 (NAICS 811310). OSHA activity number 338510431.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mcintosh Industries INC. — free Get an email when a new federal OSHA severe-injury report for Mcintosh Industries INC. is published. One employer, no account, unsubscribe in one click.
Site address
676 RAMSEY AVENUE
City
HILLSIDE
State
NJ
ZIP
07205
Mailing
676 RAMSEY AVENUE, HILLSIDE, NJ 07205
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811310
Employees
20
Ownership type
A

8 citations on file for this inspection.

1910.23 C01

Serious Gravity 5 2 instances 2 exposed
Issued
Jul 1, 2013
Abate by
Sep 3, 2013
Penalty
Initial $1,600 · Current $1,200 Reduced
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:    a) Mechanic(s) repair and service air compressor equipment located in the mechanical room above the soldering room in the back corner of the building; exposed to 11' fall hazard due to open-sided floor without railing or equivalent fall protection.      b) Mechanic(s) accessed the upper mechanical room housing the air compressors via personnel platform elevated by forklift truck where the front side of the cage was left unguarded by rail, chain or similar barrier; exposing employee(s) to falls of up to 11'.        Note:  Toeboards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $1600

1910.36 C01

Serious Gravity 5 1 instance 6 exposed
Issued
Jul 1, 2013
Abate by
Sep 19, 2013
Penalty
Initial $2,400 · Current $1,800 Reduced
29 CFR 1910.36(c)(1): Each exit discharge did not lead directly outside or to a street, walkway, refuge area, public way, or open space with access to the outside.    a) The emergency exit at the rear of the machine shop discharges to a fenced-in lot, endangering safety of employee(s) in the event of fire or other emergency necessitating evacuation of the building.    Condition(s) were noted on or about 5/8/2013.
Recent events (2)
  • — I (S) $1800
  • — Z (S) $2400

1910.37 A03

Serious Gravity 5 1 instance 4 exposed
Issued
Jul 1, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed:  a) The emergency egress route of a mechanic performing torch work on a motor armature in the NW corner of the building beneath the compressor loft was blocked by materials storage along the back wall as well as a parked forktruck.  Condition(s) were noted on or about 5/8/2013.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.37 B05

Deleted Serious Gravity 5 1 instance 4 exposed
Issued
Jul 1, 2013
Abate by
Aug 19, 2013
Penalty
Initial $1,600 · Current $0 Reduced
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit must be marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g., closet).  a) The door mid-way along the north wall from the tool shop opens directly to outside the building but leads to a fenced-in run alongside the building.  The "dead end" doorway is not marked "Not an Exit" or similarly to contraindicate its use as an emergency exit for the protection of life of machinists and other employees in the tool shop or winding area.  Condition(s) were noted on or about 5/2/2013.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1600

1910.134 C

Serious Gravity 1 1 instance 4 exposed
Issued
Jul 1, 2013
Abate by
Sep 19, 2013
Penalty
Initial $1,200 · Current $1,800
29 CFR 1910.134(c): The employer did not develop and implement a written respiratory protection program with required worksite-specific procedures and elements for required respirator use:    a) Half-mask air-purifying respirators with replaceable filters and/or chemical cartridges are required and provided by the employer for employees' protection from air contaminants such as organic solvent vapors from the varnish tank and particulates from grinding and soldering.    Condition(s) were noted on or about 5/2/2013.
Recent events (2)
  • — I (S) $1800
  • — Z (S) $1200

1910.134 E01

Serious Gravity 1 1 instance 4 exposed
Issued
Jul 1, 2013
Abate by
Sep 19, 2013
Penalty
Initial $1,200 · Current $0 Reduced
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:    a) Half-mask air-purifying respirators with replaceable chemical cartridges are required and provided by the employer for employee(s)' protection from air contaminants such as organic solvent vapors from the varnish tank and particulates from grinding and soldering.  Each respirator user was not provided a medical evaluation to ensure their physical / medical suitability to wear negative-pressure type respirator(s).    Condition(s) were noted on or about 5/2/2013.    Note:  The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1200

1910.215 B09

Serious Gravity 5 2 instances 2 exposed
Issued
Jul 1, 2013
Penalty
Initial $1,600 · Current $1,200 Reduced
29 CFR 1910.215(b)(9): Guard for abrasive wheel machine where the operator stands in front of the machine was not constructed so that the peripheral protecting member could be adjusted to the constantly decreasing diameter of the wheel:    a) The larger (Cincinnati brand) pedestal grinder was used by machinist(s) for grinding metal parts of motor armatures without peripheral guard(s) in place and adjusted to within one-quarter inch of the wheel perimeter.  Machinist(s) operating the larger pedestal grinder without the tongue guard in place were exposed to injury from flying wheel fragments in the event of rupture of the abrasive wheel during use.    Condition(s) were noted on or about 1/28/2013.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $1600

1910.1200 E01

Serious Gravity 5 1 instance 16 exposed
Issued
Jul 1, 2013
Abate by
Sep 19, 2013
Penalty
Initial $1,600 · Current $1,200 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:    a) The employer's program for chemical hazard communication was a generic guidance document, containing no site-specific inventory list or safety data sheets for the covered chemicals used at the site by employee(s).     Condition(s) were noted on or about 5/8/2013.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $1600

View Mcintosh Industries INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338510431.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.