Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: COLSON CASTER CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of COLSON CASTER CORPORATION in 3700 AIRPORT ROAD, JONESBORO, AR 72401 (NAICS 332116). OSHA activity number 338529837.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Colson Caster Corporation — free Get an email when a new federal OSHA severe-injury report for Colson Caster Corporation is published. One employer, no account, unsubscribe in one click.
Site address
3700 AIRPORT ROAD
City
JONESBORO
State
AR
ZIP
72401
Mailing
3700 AIRPORT ROAD, JONESBORO, AR 72401
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332116
Employees
77
Ownership type
A

3 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 3 instances 1 exposed
Issued
Feb 25, 2013
Abate by
Mar 19, 2013
Penalty
Initial $5,400 · Current $2,700 Reduced
29 CFR 1910.212(a)(1):     One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    On or about January 29, 2013 and times prior thereto, on dual robot welders 4615, 4616 and 4617 there were no barrier guards or devices to restrict access to the robots work envelope.  Employees entering an active robot's work envelope are exposed to struck-by and caught-in hazards.
Recent events (2)
  • — I (S) $2700
  • — Z (S) $5400

1910.219 D01

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 25, 2013
Abate by
Mar 12, 2013
Penalty
Initial $4,500 · Current $2,250 Reduced
29 CFR 1910.219(d)(1):     Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):(a)     On or about January 29, 2013 and times prior thereto the drive pulleys on the automated rack plating line were not guarded.  When the carriage is in the down position it is less than seven above the floor and presents a pinch point hazard for employees working in the area.
Recent events (2)
  • — I (S) $2250
  • — Z (S) $4500

1910.303 B02

Serious Gravity 5 1 instance 4 exposed
Issued
Feb 25, 2013
Abate by
Mar 5, 2013
Penalty
Initial $4,500 · Current $2,250 Reduced
29 CFR 1910.303(b)(2):     Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    On or about January 29, 2013 and times prior thereto, in the maintenance area above the weld table the employer had in use an electrical box designed to be mounted on a flat surface being used as a drop pendant.  Improper use of this equipment exposes employees to the hazards of an electrical shock.
Recent events (2)
  • — I (S) $2250
  • — Z (S) $4500

View Colson Caster Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338529837.