On , OSHA opened a planned safety inspection of COLSON CASTER CORPORATION in 3700 AIRPORT ROAD, JONESBORO, AR 72401 (NAICS 332116). OSHA activity number 338529837.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COLSON CASTER CORPORATION
- Site address
- 3700 AIRPORT ROAD
- City
- JONESBORO
- State
- AR
- ZIP
- 72401
- Mailing
- 3700 AIRPORT ROAD, JONESBORO, AR 72401
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332116
- Employees
- 77
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.212 A01
- Issued
- Feb 25, 2013
- Abate by
- Mar 19, 2013
- Penalty
- Initial $5,400 · Current $2,700 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or about January 29, 2013 and times prior thereto, on dual robot welders 4615, 4616 and 4617 there were no barrier guards or devices to restrict access to the robots work envelope. Employees entering an active robot's work envelope are exposed to struck-by and caught-in hazards.
Recent events (2)
- — I (S) $2700
- — Z (S) $5400
1910.219 D01
- Issued
- Feb 25, 2013
- Abate by
- Mar 12, 2013
- Penalty
- Initial $4,500 · Current $2,250 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):(a) On or about January 29, 2013 and times prior thereto the drive pulleys on the automated rack plating line were not guarded. When the carriage is in the down position it is less than seven above the floor and presents a pinch point hazard for employees working in the area.
Recent events (2)
- — I (S) $2250
- — Z (S) $4500
1910.303 B02
- Issued
- Feb 25, 2013
- Abate by
- Mar 5, 2013
- Penalty
- Initial $4,500 · Current $2,250 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: On or about January 29, 2013 and times prior thereto, in the maintenance area above the weld table the employer had in use an electrical box designed to be mounted on a flat surface being used as a drop pendant. Improper use of this equipment exposes employees to the hazards of an electrical shock.
Recent events (2)
- — I (S) $2250
- — Z (S) $4500
More inspections at Colson Caster Corporation
View Colson Caster Corporation's full OSHA safety record →
More inspections in this industry (NAICS 332116)
More inspections in AR
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338529837.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.