Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: EMANOUIL DEVELOPMENT, LLC

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of EMANOUIL DEVELOPMENT, LLC in 82 INDIAN RIDGE TERRACE, WESTFORD, MA 01886 (NAICS 236115). OSHA activity number 338530439.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Emanouil Development, LLC — free Get an email when a new federal OSHA severe-injury report for Emanouil Development, LLC is published. One employer, no account, unsubscribe in one click.
Site address
82 INDIAN RIDGE TERRACE
City
WESTFORD
State
MA
ZIP
01886
Mailing
17 PROGRESS AVENUE, CHELMSFORD, MA 01824
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
Employees
90
Ownership type
A

4 citations on file for this inspection.

1910.1200 F09

Serious Gravity 1 1 instance 1 exposed
Issued
Mar 18, 2013
Abate by
Mar 28, 2013
Penalty
Initial $2,100 · Current $1,260 Reduced
29 CFR 1910.1200(f)(9):     The employer shall ensure that labels or other forms of warning are legible, in English, and prominently displayed on the container, or readily available in the work area throughout each work shift. Employers having employees who speak other languages may add the information in their language to the material presented, as long as the information is presented in English as well.    (a) Location - Indian Ridge, Westford, MA:    On or about 1/28/13, the employer failed to ensure that LP gas containers were appropriately labeled.
Recent events (2)
  • — I (S) $1260
  • — Z (S) $2100

1926.153 H11

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 18, 2013
Abate by
Apr 18, 2013
Penalty
Initial $2,800 · Current $1,640 Reduced
29 CFR 1926.153(h)(11):     Containers having a water capacity greater than 2 1/2 pounds (nominal 1 pound LP-Gas capacity) connected for use shall stand on a firm and substantially level surface and, when necessary, shall be secured in an upright position.    (a) Location - Indian Ridge, Westford, MA:    On or about 1/28/13, the employer failed to secure a 100-pound LP gas container while it was in use.
Recent events (2)
  • — I (S) $1640
  • — Z (S) $2800

1926.153 H13

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 18, 2013
Abate by
Apr 18, 2013
Penalty
Initial $3,500 · Current $0 Reduced
29 CFR 1926.153(h)(13):     For temporary heating, heaters (other than integral heater-container units) shall be located at least 6 feet from any LP-Gas container. This shall not prohibit the use of heaters specifically designed for attachment to the container or to a supporting standard, provided they are designed and installed so as to prevent direct or radiant heat application from the heater onto the containers. Blower and radiant type heaters shall not be directed toward any LP-Gas container within 20 feet.    (a) Location - Indian Ridge, Westford, MA:    On or about 1/28/13, the employer failed to ensure that a space heater was at least 6 feet from a LP gas container.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3500

1926.404 B01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 18, 2013
Abate by
Apr 18, 2013
Penalty
Initial $3,500 · Current $2,000 Reduced
29 CFR 1926.404(b)(1)(ii):     Ground-fault circuit interrupters. All 120-volt, single-phase 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.    (a) Location - Indian Ridge, Westford, MA:    On or about 1/28/12, the employer failed to provide ground-fault circuit protection for emloyees using a 6500-watt generator.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $3500

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338530439.