WESTFORD, MA —
OSHA Inspection: EMANOUIL DEVELOPMENT, LLC
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of EMANOUIL DEVELOPMENT, LLC in 82 INDIAN RIDGE TERRACE, WESTFORD, MA 01886 (NAICS 236115). OSHA activity number 338530439.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EMANOUIL DEVELOPMENT, LLC
- Site address
- 82 INDIAN RIDGE TERRACE
- City
- WESTFORD
- State
- MA
- ZIP
- 01886
- Mailing
- 17 PROGRESS AVENUE, CHELMSFORD, MA 01824
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236115
- Employees
- 90
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.1200 F09
- Issued
- Mar 18, 2013
- Abate by
- Mar 28, 2013
- Penalty
- Initial $2,100 · Current $1,260 Reduced
General-duty citation text
29 CFR 1910.1200(f)(9): The employer shall ensure that labels or other forms of warning are legible, in English, and prominently displayed on the container, or readily available in the work area throughout each work shift. Employers having employees who speak other languages may add the information in their language to the material presented, as long as the information is presented in English as well. (a) Location - Indian Ridge, Westford, MA: On or about 1/28/13, the employer failed to ensure that LP gas containers were appropriately labeled.
Recent events (2)
- — I (S) $1260
- — Z (S) $2100
1926.153 H11
- Issued
- Mar 18, 2013
- Abate by
- Apr 18, 2013
- Penalty
- Initial $2,800 · Current $1,640 Reduced
General-duty citation text
29 CFR 1926.153(h)(11): Containers having a water capacity greater than 2 1/2 pounds (nominal 1 pound LP-Gas capacity) connected for use shall stand on a firm and substantially level surface and, when necessary, shall be secured in an upright position. (a) Location - Indian Ridge, Westford, MA: On or about 1/28/13, the employer failed to secure a 100-pound LP gas container while it was in use.
Recent events (2)
- — I (S) $1640
- — Z (S) $2800
1926.153 H13
- Issued
- Mar 18, 2013
- Abate by
- Apr 18, 2013
- Penalty
- Initial $3,500 · Current $0 Reduced
General-duty citation text
29 CFR 1926.153(h)(13): For temporary heating, heaters (other than integral heater-container units) shall be located at least 6 feet from any LP-Gas container. This shall not prohibit the use of heaters specifically designed for attachment to the container or to a supporting standard, provided they are designed and installed so as to prevent direct or radiant heat application from the heater onto the containers. Blower and radiant type heaters shall not be directed toward any LP-Gas container within 20 feet. (a) Location - Indian Ridge, Westford, MA: On or about 1/28/13, the employer failed to ensure that a space heater was at least 6 feet from a LP gas container.
Recent events (2)
- — I (S) $0
- — Z (S) $3500
1926.404 B01 II
- Issued
- Mar 18, 2013
- Abate by
- Apr 18, 2013
- Penalty
- Initial $3,500 · Current $2,000 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(ii): Ground-fault circuit interrupters. All 120-volt, single-phase 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters. (a) Location - Indian Ridge, Westford, MA: On or about 1/28/12, the employer failed to provide ground-fault circuit protection for emloyees using a 6500-watt generator.
Recent events (2)
- — I (S) $2000
- — Z (S) $3500
More inspections in this industry (NAICS 236115)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338530439.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.