ORANGE PARK, FL —
OSHA Inspection: BR RENOVATIONS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BR RENOVATIONS, INC. in 516 GLENDALE LANE, ORANGE PARK, FL 32065 (NAICS 238160). OSHA activity number 338544430.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BR RENOVATIONS, INC.
- Site address
- 516 GLENDALE LANE
- City
- ORANGE PARK
- State
- FL
- ZIP
- 32065
- Mailing
- 9617 SCOTT MILL ROAD, JACKSONVILLE, FL 32257
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 2
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.102 A01
- Issued
- Feb 8, 2013
- Penalty
- Initial $1,200 · Current $720 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a. On or about January 29, 2013, an employee using a Hitachi NV45AB2 pneumatic air nail gun did not have safety glasses, exposing himself to being hit by nails or flying debris.
Recent events (2)
- — I (S) $720
- — Z (S) $1200
1926.501 B13
- Issued
- Feb 8, 2013
- Penalty
- Initial $2,400 · Current $1,440 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On or about January 29, 2013, on a 6:12 pitch roof, two employees were not protected from a 10 feet 2-inch fall hazard by use of a guardrail system, safety net system, personal fall arrest system or any alternate fall protection.
Recent events (2)
- — I (S) $1440
- — Z (S) $2400
1926.1053 B01
- Issued
- Feb 8, 2013
- Penalty
- Initial $1,600 · Current $960 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a. On or about January 29, 2013, two employees used 28 foot Werner extension ladder to access a roof that did not extend 3 feet over the eave nor was secured from slippage, exposing themselves to a fall hazard.
Recent events (2)
- — I (S) $960
- — Z (S) $1600
More inspections at BR Renovations, INC.
View BR Renovations, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338544430.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.