Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SUPERIOR SERVICES GROUP CORP

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SUPERIOR SERVICES GROUP CORP in 1206 S FEDERAL HIGHWAY, DELRAY BEACH, FL 33483 (NAICS 238140). OSHA activity number 338549231.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Superior Services Group Corp — free Get an email when a new federal OSHA severe-injury report for Superior Services Group Corp is published. One employer, no account, unsubscribe in one click.
Site address
1206 S FEDERAL HIGHWAY
City
DELRAY BEACH
State
FL
ZIP
33483
Mailing
187 NW 91ST STREET, MIAMI, FL 33172
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
30
Ownership type
A

5 citations on file for this inspection.

1926.451 G01

Serious Gravity 10 1 instance 1 exposed
Issued
Jun 19, 2013
Penalty
Initial $4,900 · Current $4,900
29 CFR 1926.451(g)(1): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section:  a.  On or about January 24, 2013, at the above addressed job site, employees were exposed to a fall hazard while conducting concrete forming work from a fabricated frame scaffold without using a means of conventional fall protection.
Recent events (1)
  • — Z (S) $4900

1926.451 B01

Serious Gravity 10 1 instance 1 exposed
Issued
Jun 19, 2013
Penalty
Initial $4,900 · Current $4,900
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii):  a.  On or about January 24, 2013, at the above addressed job site, at the above addressed jobsite, an employee was exposed to a fall hazard while conducting concrete forming work from a fabricated frame scaffold that was not fully planked.
Recent events (1)
  • — Z (S) $4900

1926.451 C03

Serious Gravity 10 1 instance 1 exposed
Issued
Jun 19, 2013
Penalty
Initial $4,900 · Current $4,900
29 CFR 1926.451(c)(3): Supported scaffold poles, legs, posts, frames, and uprights shall be plumb and braced to prevent swaying and displacement:  a.   On or about January 24, 2013, at the above addressed job site, employees were exposed to a fall hazard while conducting concrete forming work from a defective fabricated frame scaffold that had separated end frames.
Recent events (1)
  • — Z (S) $4900

1926.451 E01

Serious Gravity 10 1 instance 1 exposed
Issued
Jun 19, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.451(e)(1): When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used:  a.   On or about January 24, 2013, at the above addressed job site, employees were exposed to a fall hazard while gaining access to a fabricated frame scaffold which was not equipped with access ladders.
Recent events (1)
  • — Z (S) $0

1926.451 F03

Serious Gravity 10 1 instance 1 exposed
Issued
Jun 19, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.451(f)(3): Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity:  a.   On or about January 24, 2013, at the above addressed job site, employees were exposed to a fall hazard while conducting concrete forming work from a fabricated frame scaffold that had not been inspected by a competent person.
Recent events (1)
  • — Z (S) $0

View Superior Services Group Corp's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338549231.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.