Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DAY-PAK, INC

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of DAY-PAK, INC in 2208 SANDRIDGE DRIVE, DAYTON, OH 45439 (NAICS 326112). OSHA activity number 338568439.

Watch Day-Pak, INC — free Get an email when a new federal OSHA severe-injury report for Day-Pak, INC is published. One employer, no account, unsubscribe in one click.
Establishment
DAY-PAK, INC
Site address
2208 SANDRIDGE DRIVE
City
DAYTON
State
OH
ZIP
45439
Mailing
2208 SANDRIDGE DRIVE, DAYTON, OH 45439
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326112
Employees
30
Ownership type
A

7 citations on file for this inspection.

1910.147 D03

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $0.00 Reduced
29 CFR 1910.147(d)(3):     Machine or equipment isolation. All energy isolating devices that are needed to control the energy to the machine or equipment shall be physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s).      a) On or about December 20, 2012 electrical disconnect was not operated to disable power to the Schjeldahl bag machine during a miss feed and/or jam up.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2800

1910.147 D04 I

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(d)(4)(i):     Lockout or tagout devices shall be affixed to each energy isolating device by authorized employees.      a) On or about December 20, 2012 prior to performing maintenance and/or removing a jam up on the bag machine      employee(s) did not attach a lockout device to the energy isolation point.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1400.00 Reduced
29 CFR 1910.147(c)(1):     Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative.      a) The company did not establish a written program consisting of training, procedures and review to address the unintended release and/or start up of energy sources.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.219 F03

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1400.00 Reduced
29 CFR 1910.219(f)(3):     Sprockets and chains. All sprocket wheels and chains shall be enclosed unless they are more than seven (7) feet above the floor or platform. Where the drive extends over other machine or working areas, protection against falling shall be provided. This subparagraph does not apply to manually operated sprockets.      a) Chains and sprockets were not guarded on Motor drive for the Weise bag machine exposing employees to rotating parts.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.219 E03 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1400.00 Reduced
29 CFR 1910.219(e)(3)(i):     Vertical and inclined belts shall be enclosed by a guard conforming to standards in paragraphs (m) and (o) of this section.      a) Machine guarding was not provided for the motor drive belt on the Rosenthal perferator machine exposing employees to pinch point hazards.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.303 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1400.00 Reduced
29 CFR 1910.303(b)(1):     Examination. Electric equipment shall be free from recognized hazards that are likely to cause death or serious physical harm to employees. Safety of equipment shall be determined using the following considerations:    a) On the Schjeldahl bag machine the junction box supplying power to the main motor drive was open, exposing conductors connected by wire nuts.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.219 C02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1400.00 Reduced
29 CFR 1910.219(c)(2)(i):     All exposed parts of horizontal shafting seven (7) feet or less from floor or working platform, excepting runways used exclusively for oiling, or running adjustments, shall be protected by a stationary casing enclosing shafting completely or by a trough enclosing sides and top or sides and bottom of shafting as location requires.    a) Drive shaft attached to the Rosenthal machine motor drive was not guarded to prevent employees exposure to rotating parts.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338568439.