JAMESVILLE, NY —
OSHA Inspection: CHRISTIANA MILLWORK INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CHRISTIANA MILLWORK INC. in 4755 JAMESVILLE ROAD, JAMESVILLE, NY 13078 (NAICS 321918). OSHA activity number 338583834.
Where did this inspection happen?
- Establishment
- CHRISTIANA MILLWORK INC.
- Site address
- 4755 JAMESVILLE ROAD
- City
- JAMESVILLE
- State
- NY
- ZIP
- 13078
- Mailing
- 4755 JAMESVILLE ROAD, JAMESVILLE, NY 13078
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321918
- Employees
- 20
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.212 A01
- Issued
- Feb 25, 2013
- Abate by
- Mar 30, 2013
- Penalty
- Initial $2,000 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Bldg. 1, on or about 1/31/13: Rotating chuck on a Delta drill press was not guarded. b) Bldg. 1, on or about 1/31/13: Ingoing nip points on the tape feeder and pressure rolls and the point of operation at the guillotine cutter on a SE-9600 Homag edge bander were not guarded. c) Bldg. 4, on or about 1/31/13: Point of operation on a Grass boring machine was not guarded Abatement certification must be submitted for these items.
Recent events (2)
- — I (S) $1400
- — Z (S) $2000
1910.213 P04
- Issued
- Feb 25, 2013
- Abate by
- Mar 30, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(p)(4): Belt sanding machinery was not provided with a guard at each nip point where the sanding belt ran onto a pulley, to prevent the operator's hands or fingers from coming into contact with nip points: a) Bldg. 2, on or about 1/31/13: Ingoing nip points on a Powermatic belt edge sander were not guarded. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.213 J03
- Issued
- Feb 25, 2013
- Abate by
- Mar 30, 2013
- Penalty
- Initial $1,600 · Current $1,120 Reduced
General-duty citation text
29 CFR 1910.213(j)(3): Hand-fed jointer(s) with horizontal cutting head(s) did not have automatic guard(s) which automatically adjusted to cover the unused portion of the head and/or remained in contact with the material at all times: a) Bldg. 3, on or about 1/31/13: The guard on a SCM410 jointer did not automatically adjust to cover the unused portion of the cutting head. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $1120
- — Z (S) $1600
1910.213 S06
- Issued
- Feb 25, 2013
- Abate by
- Mar 30, 2013
- Penalty
- Initial $2,000 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.213(s)(6): Cleanliness around working machinery was not maintained to prevent fire hazards: a) Throughout the facility, on or about 1/31/13: Wood dust had accumulated on the floors, around machinery and on electrical equipment. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $1400
- — Z (S) $2000
1910.303 B02
- Issued
- Feb 25, 2013
- Abate by
- Mar 30, 2013
- Penalty
- Initial $1,200 · Current $840 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) Bldg. 4, on or about 1/31/13: A relocatable power tap (strip outlet) connected to a flexible extension cord used to supply power to battery chargers, tools, etc. was permanently attached to the workbench and being used as permanent wiring which was not in accordance with the listing and labeling. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $840
- — Z (S) $1200
1910.304 G06 VI
- Issued
- Feb 25, 2013
- Abate by
- Mar 30, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(g)(6)(vi): Exposed noncurrent-carrying metal parts of cord- and plug-connected equipment that could have become energized were not grounded: a) Bldg. 1, on or about 1/31/13: Power feed for the Powermatic table saw was not grounded in that the ground pin was missing from the plug end. b) Bldg. 3, on or about 1/31/13: Lakewood floor fan was not grounded in that the ground pin was missing from the plug end. Abatement certification must be submitted for these items.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Christiana Millwork INC.