NEENAH, WI —
OSHA Inspection: UNITED PLASTICS FABRICATING, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of UNITED PLASTICS FABRICATING, INC. in 219 ROCKWOOD LANE, NEENAH, WI 54956 (NAICS 326199). OSHA activity number 338592033.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- UNITED PLASTICS FABRICATING, INC.
- Site address
- 219 ROCKWOOD LANE
- City
- NEENAH
- State
- WI
- ZIP
- 54956
- Mailing
- 165 FLAGSHIP DRIVE, NORTH ANDOVER, MA 01845
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 103
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.146 C05 II C
- Issued
- Apr 18, 2013
- Abate by
- May 29, 2013
- Penalty
- Initial $3,060 · Current $2,142 Reduced
General-duty citation text
29 CFR 1910.146(c)(5)(ii)(C): Employees entered into permit spaces that met the conditions set forth in 29 CFR 1910.146(c)(5)(i) but before an employee entered the space, the internal atmosphere was not tested with a calibrated direct-reading instrument: a) On 02/28/2012, the internal atmosphere of a 2000 gallon elliptical tank was not tested with a calibrated direct-reading instrument for oxygen before an employee entered into the confined space. ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED.
Recent events (2)
- — I (S) $2142
- — Z (S) $3060
1910.146 C05 II F
- Issued
- Apr 18, 2013
- Abate by
- May 29, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.146(c)(5)(ii)(F): Employees entered into permit spaces that met the conditions set forth in 29 CFR 1910.146(c)(5)(i) but the atmosphere within space was not periodically tested to ensure that the continuous forced air ventilation was preventing the accumulation of a hazardous atmosphere: a) On 02/28/2012, the internal atmosphere of a 2000 gallon elliptical tank was not periodically tested to ensure the continuous forced air ventilation was preventing an oxygen deficient atmosphere due to nitrogen gas displacement of oxygen. ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.146 C05 II H
- Issued
- Apr 18, 2013
- Abate by
- May 29, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.146(c)(5)(ii)(H): Employees entered into permit spaces that met the conditions set forth in 29 CFR 1910.146(c)(5)(i), but a written certification was not made before entry that the measures required by 29 CFR 1910.146(c)(5)(ii) had been taken: a) On 02/28/2012, a written certification of the measures required by 29 CFR 1910.146(c)(5)(ii) was not made before employees entered a 2000 gallon elliptical tank. ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at United Plastics Fabricating, INC.
View United Plastics Fabricating, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 326199)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338592033.