VERNON, CT —
OSHA Inspection: MIDAS
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of MIDAS in 67 WINDSOR AVENUE, VERNON, CT 06066 (NAICS 811111). OSHA activity number 338599632.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MIDAS
- Site address
- 67 WINDSOR AVENUE
- City
- VERNON
- State
- CT
- ZIP
- 06066
- Mailing
- 67 WINDSOR AVENUE, VERNON, CT 06066
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811111
- Employees
- 5
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.22 A02
- Issued
- Mar 19, 2013
- Abate by
- Apr 12, 2013
- Penalty
- Initial $2,400 · Current $0 Reduced
General-duty citation text
29 CFR 1910.22(a)(2): Floor(s) of workroom(s) were not maintained in a clean and, so far as possible, a dry condition: 67 Windsor Avenue, Vernon, CT 06066 on or about 01/31/2013: Water leaking from the building roof to the work area floor created a slipping hazard
Recent events (3)
- — F (S) $0
- — C (S) $2400
- — Z (S) $2400
1910.23 C01
- Issued
- Mar 19, 2013
- Abate by
- Apr 12, 2013
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent). 67 Windsor Avenue, Vernon, CT 06066: the employer did not provide a guard rail system for the rack system walkway that was seven feet five inches above the ground level.
Recent events (3)
- — F (S) $0
- — C (S) $2800
- — Z (S) $2800
1910.36 G02
- Issued
- Mar 19, 2013
- Abate by
- Apr 12, 2013
- Penalty
- Initial $1,600 · Current $0 Reduced
General-duty citation text
29 CFR 1910.36(g)(2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points. 67 Windsor Avenue, Vernon, CT 06066: The employer did not maintain the main work area exit access at 28 inches at all points.
Recent events (3)
- — F (S) $0
- — C (S) $1600
- — Z (S) $1600
1910.157 C01
- Issued
- Mar 19, 2013
- Abate by
- Apr 12, 2013
- Penalty
- Initial $1,200 · Current $0 Reduced
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries 67 Windsor Avenue, Vernon, CT 06066 on or about 01/31/2013: The employer did not mount the fire extinguishers used in the main work area. The fire extinguishers were placed on the floor near vehicular traffic.
Recent events (3)
- — F (S) $0
- — C (S) $1200
- — Z (S) $1200
1910.157 E03
- Issued
- Mar 19, 2013
- Abate by
- Apr 12, 2013
- Penalty
- Initial $1,600 · Current $0 Reduced
General-duty citation text
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check 67 Windsor Avenue, Vernon, CT 06066 on or about 01/31/2013 the employer did not ensure that all fire extinguishers that were in the work area were subjected to an annual maintenance check.
Recent events (3)
- — F (S) $0
- — C (S) $1600
- — Z (S) $1600
1910.215 A01
- Issued
- Mar 19, 2013
- Abate by
- Apr 12, 2013
- Penalty
- Initial $1,600 · Current $0 Reduced
General-duty citation text
29 CFR 1910.215(a)(1): Abrasive wheel(s) used on grinding machinery were not used with safety guard(s): 67 Windsor Avenue, Vernon, CT 06066 on or about 01/31/2013: The employer did not provide the necessary abrasive wheel guards for two bench grinders.
Recent events (3)
- — F (S) $0
- — C (S) $1600
- — Z (S) $1600
1910.253 B04 III
- Issued
- Mar 19, 2013
- Abate by
- Apr 12, 2013
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour: 67 Windsor Avenue, Vernon, CT 06066 on or about 01/31/2013: Oxygen Cylinder and Acetylene Cylinder were not separated the required minimum distance or by the required noncombustible barrier.
Recent events (3)
- — F (S) $0
- — C (S) $2800
- — Z (S) $2800
More inspections at Midas
View Midas's full OSHA safety record →
More inspections in this industry (NAICS 811111)
More inspections in CT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338599632.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.