Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FRANCA SERVICES, INC.

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of FRANCA SERVICES, INC. in INDIAN RIDGE TERRACE, WESTFORD, MA 01886 (NAICS 238170). OSHA activity number 338629033.

Watch Franca Services, INC. — free Get an email when a new federal OSHA severe-injury report for Franca Services, INC. is published. One employer, no account, unsubscribe in one click.
Site address
INDIAN RIDGE TERRACE
City
WESTFORD
State
MA
ZIP
01886
Mailing
449 BOSTON POST ROAD #E1, MARLBOROUGH, MA 01752
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
13
Ownership type
A

5 citations on file for this inspection.

1926.451 B03

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $970.00 Reduced
29 CFR 1926.451(b)(3):     Except as provided in paragraphs (b)(3)(i) and (ii) of this section, the front edge of all platforms shall not be more than 14 inches (36 cm) from the face of the work, unless guardrail systems are erected along the front edge and/or personal fall arrest systems are used in accordance with paragraph (g) of this section to protect employees from falling.    (a) Location - Indian Ridge, Westford, MA:    On or about 2/1/13, the employer failed to ensure that the front edge of a scaffold platform was less than 14 inches to the face of the work.
Recent events (2)
  • — I (S) $970
  • — Z (S) $1600

1926.451 C02

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $970.00 Reduced
29 CFR 1926.451(c)(2):     Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.    (a) Location - Indian Ridge, Westford, MA:    On or about 2/1/13, the employer failed to ensure that pump jack scaffold legs were positioned on base plates, mud sills or other adequate firm foundation.
Recent events (2)
  • — I (S) $970
  • — Z (S) $1600

1926.451 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $0.00 Reduced
29 CFR 1926.451(e)(1):     When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.    (a) Location - Indian Ridge, Westford, MA:    On or about 2/1/13, the employer failed to provide suitable access to a pump jack scaffold.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2000

1926.451 G01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1100.00 Reduced
29 CFR 1926.451(g)(1):     Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers.    (a) Location - Indian Ridge, Westford, MA:    On or about 2/1/13, the employer failed to ensure that workers on a scaffold more than ten feet above a lower level were provided with adequate fall protection (guard rails) on the ends of the platform.
Recent events (2)
  • — I (S) $1100
  • — Z (S) $2000

1926.452 J02

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $960.00 Reduced
29 CFR 1926.452(j)(2):     Poles shall be secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. When the pump jack has to pass bracing already installed, an additional brace shall be installed approximately 4 feet (1.2 m) above the brace to be passed, and shall be left in place until the pump jack has been moved and the original brace reinstalled.    (a) Location - Indian Ridge, Westford, MA:    On or about 2-1-13, the employer failed to ensure that a pump jack scaffold was secured at the bottom.
Recent events (2)
  • — I (S) $960
  • — Z (S) $2000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338629033.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.