Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ACCURATE MASONRY OF TEXAS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ACCURATE MASONRY OF TEXAS, INC. in 12301 SOUTH FREEWAY, FORT WORTH, TX 76101 (NAICS 238140). OSHA activity number 338630635.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Accurate Masonry of Texas, INC. — free Get an email when a new federal OSHA severe-injury report for Accurate Masonry of Texas, INC. is published. One employer, no account, unsubscribe in one click.
Site address
12301 SOUTH FREEWAY
City
FORT WORTH
State
TX
ZIP
76101
Mailing
2410 MINNIS DR. SUITE 164, FORT WORTH, TX 76117
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
15
Ownership type
A

2 citations on file for this inspection.

1926.451 B01 I

Serious Gravity 5 1 instance 6 exposed
Issued
Mar 1, 2013
Abate by
Mar 27, 2013
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary.      On February 1, 2013, on the east side of the construction site, an employee was observed working from the second level of a tubular welded frame scaffold that was not fully planked.  The working platform of the scaffold consisted of only one plank exposing the employee to a fall hazard of approximately 12 feet to the ground below.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1926.451 G01

Serious Gravity 5 1 instance 6 exposed
Issued
Mar 1, 2013
Abate by
Mar 27, 2013
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section.      On February 1, 2013, on the east side of the construction site, an employees was observed working from the second level  of a tubular welded frame scaffold without a fall protective system.  The employee was performing masonry activates to the exterior pillars underneath a canopy, and was exposed to a fall hazard approximately 12 feet to the ground below.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

View Accurate Masonry of Texas, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338630635.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.