MOORESTOWN, NJ —
OSHA Inspection: A ACTION FAMILY MOVING CO. INC. DBA TRANSTAR MOVING SYSTEMS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of A ACTION FAMILY MOVING CO. INC. DBA TRANSTAR MOVING SYSTEMS in 925 N LENOLA ROAD, MOORESTOWN, NJ 08057 (NAICS 484121). OSHA activity number 338646235.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Site address
- 925 N LENOLA ROAD
- City
- MOORESTOWN
- State
- NJ
- ZIP
- 08057
- Mailing
- 925 N LENOLA ROAD, MOORESTOWN, NJ 08057
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 484121
- Employees
- 50
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.178 L01 I
- Issued
- May 9, 2013
- Abate by
- Jun 5, 2013
- Penalty
- Initial $3,500 · Current $1,750 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): a) Warehouse: The employer did not provide training to employees operating a Hyster forklift Model # GLC050TGNUAE088, Serial # E187V09138W, occurred on or about 1/30/2013.
Recent events (2)
- — I (S) $1750
- — Z (S) $3500
1910.213 A09
- Issued
- May 9, 2013
- Abate by
- Jun 5, 2013
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1910.213(a)(9): All belts, pulleys, gears, shafts, and moving parts were not guarded in accordance with the specific requirements of 1910.219: (a) Warehouse - wood working area: A belt and Pulley on the table saw model # 113.27 521 were not guarded, occurred on or about 1/31/2013.
Recent events (2)
- — I (S) $0
- — Z (S) $2800
1910.213 C02
- Issued
- May 9, 2013
- Abate by
- Jun 5, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(c)(2): Handfed circular ripsaw(s) were not furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator: (a) Warehouse - wood working area: The table saw was not furnished with a spreader to prevent pieces of wood being thrown back on the operator, occurred on or about 01/31/2013.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.213 C03
- Issued
- May 9, 2013
- Abate by
- Jun 5, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(c)(3): Each hand-fed circular ripsaw was not provided with nonkickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator. They were not designed to provide adequate holding power for all the thicknesses of materials being cut. (a) Warehouse - wood working area: The table saw Model # 113.27 521, was not provided with kickback fingers, occurred on or about 01/31/2013.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.213 D01
- Issued
- May 9, 2013
- Abate by
- Jun 5, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(d)(1): Circular handfed crosscut table saw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: (a) Warehouse - wood working area: Employees were exposed to amputations while using a table saw without a saw hood guard, occurred on or about 01/31/2013.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B01 II
- Issued
- May 9, 2013
- Abate by
- Jun 5, 2013
- Penalty
- Initial $2,100 · Current $1,050 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a) Rear warehouse - near exit: The electrical panel box LP-1 had exposed electrical cables where there were missing circuit breakers, occurred on or about 01/31/2013. b) Rear warehouse - near exit: The electrical panel box LP-1 had a missing knock out, occurred on or about 01/31/2013.
Recent events (2)
- — I (S) $1050
- — Z (S) $2100
1910.157 G02
- Issued
- May 9, 2013
- Abate by
- Jun 5, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter: a) Warehouse: The company did not train the warehouse employees on the principles of fire extinguisher use, occurred on or about 1/31/2013.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 484121)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338646235.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.