BOSTON, MA —
OSHA Inspection: MAJC GENERAL CONTRACTOR, INCORPORATED
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of MAJC GENERAL CONTRACTOR, INCORPORATED in 1959 COMMONWEALTH AVENUE, BOSTON, MA 02135 (NAICS 238140). OSHA activity number 338679640.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MAJC GENERAL CONTRACTOR, INCORPORATED
- Site address
- 1959 COMMONWEALTH AVENUE
- City
- BOSTON
- State
- MA
- ZIP
- 02135
- Mailing
- 311 PROCTOR AVENUE, REVERE, MA 02151
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 3
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.404 A02
- Issued
- Jun 5, 2013
- Abate by
- Jun 13, 2013
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1926.404(a)(2): A grounded conductor was attached to a terminal or lead so as to reverse designated polarity: Jobsite: Roof. A multi-tap device was missing the safety grounding pin and had been plugged into an extension cord upside-down creating a reverse polarity.
Recent events (2)
- — I (S) $1200
- — Z (S) $1200
1926.404 F06
- Issued
- Jun 5, 2013
- Abate by
- Jun 13, 2013
- Penalty
- Initial $1,200 · Current $0 Reduced
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: Jobsite: Roof. Two (2) extension cords were missing the safety grounding pins.
Recent events (2)
- — I (S) $0
- — Z (S) $1200
1926.405 A02 II I
- Issued
- Jun 5, 2013
- Abate by
- Jun 13, 2013
- Penalty
- Initial $1,200 · Current $0 Reduced
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(I): Flexible cords and cables used for temporary wiring were not protected from damage: Jobsite: Roof. Two (2) extension cords were exposed to physical damage while in use where the cords were draped over the metal roof edging and was suspended for four (4) stories.
Recent events (2)
- — I (S) $0
- — Z (S) $1200
1926.451 C02 II
- Issued
- Jun 5, 2013
- Abate by
- Jun 14, 2013
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.451(c)(2)(ii): Unstable objects were used to support scaffolds or platform units: Jobsite: Front of building. Several scaffold legs were supported upon sills that were partially hanging in free air as they were cantilevered out passed the flower bed curbings.
Recent events (2)
- — I (S) $2800
- — Z (S) $2800
1926.451 F03
- Issued
- Jun 5, 2013
- Abate by
- Jun 19, 2013
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: Jobsite: Site. A competent person had not inspected the scaffold structure where numerous defects existed such as lack of fall protection, unstable footings, and inadequate access.
Recent events (2)
- — I (S) $0
- — Z (S) $2800
1926.451 E06 VI
- Issued
- Jun 5, 2013
- Abate by
- Jun 13, 2013
- Penalty
- Initial $2,800 · Current $1,820 Reduced
General-duty citation text
29 CFR 1926.451(e)(6)(vi): 1926.451(e)(6)(vi): Integral prefabricated scaffold access frames being used for access had a spacing greater than 16 3/4 inches: Jobsite: Front of building. Employees were exposed to falls of up to approximately 40 feet while accessing their work zones within the tubular welded frame scaffold structure by climbing the frames where the horizontal members were not uniformly spaced and were spaced as far as 20 inches apart.
Recent events (2)
- — I (S) $1820
- — Z (S) $2800
1926.451 G01
- Issued
- Jun 5, 2013
- Abate by
- Jun 13, 2013
- Penalty
- Initial $2,800 · Current $1,820 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level was not protected from falling to the lower level: Jobsite: Front of building. A worker was seriously injured when he fell approximately 15 feet from an upper level onto a lower level within the tubular welded frame scaffold structure.
Recent events (2)
- — I (S) $1820
- — Z (S) $2800
More inspections in this industry (NAICS 238140)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338679640.