Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CORIX UTILITIES, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of CORIX UTILITIES, INC. in 155 E. BOARDWALK DRIVE, FORT COLLINS, CO 80525 (NAICS 237130). OSHA activity number 338685068.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Corix Utilities, INC. — free Get an email when a new federal OSHA severe-injury report for Corix Utilities, INC. is published. One employer, no account, unsubscribe in one click.
Site address
155 E. BOARDWALK DRIVE
City
FORT COLLINS
State
CO
ZIP
80525
Mailing
11020 W. PLANK CT. STE 100, WAUWATOSA, WI 53226
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237130
Employees
28
Ownership type
A

2 citations on file for this inspection.

1926.21 B02

Other-than-serious 1 instance 1 exposed
Issued
Jul 3, 2013
Abate by
Jul 10, 2014
Penalty
Initial $7,000 · Current $2,000 Reduced
29 CFR 1926.21(b)(2):     The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.    On or about March 1, 2013, an employee was unaware of the exact fabric makeup of the undergarments he was wearing while working for the employer on the employer on the employer on January 16, 2013.
Recent events (3)
  • — F (O) $2000
  • — C (S) $7000
  • — Z (S) $7000

1910.335 A02 II

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Jul 3, 2013
Abate by
Jul 24, 2013
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.335(a)(2)(ii): Protective shields, protective barriers, or insulating materials shall be used to protect each employee from shock, burns, or other electrically related injuries while that employee is working near exposed energized parts which might be accidentally contated or where dangerous electric heating or arcing might occur:   (a) Corix Utilities, Inc. @ 155 E. Boardwalk Dr., Fort Collins, CO 80525: On and before January 16th, 2013, the employer did not ensure that employees were fully protected from arc flash injuries by the use of protective shields, barriers or insulating materials during the removal and installation of an electric meter. On January 16th, 2013, an employee was inserting a new AMI electrical meter into a meter socket involving 277/480V switchgear with the load and line energized, when an arc flash/blast occurred. The employee received burns to the ears and head as a result. This condition exposed employees to burns associated with arc flash and arc blast incidents.     An acceptable abatement method would be to incorporate the use of protective shields, protective barriers or insulative materials that fully protect the employee from hazardous energy, including thermal energy.  Another feasible and acceptable method of abatement may be achieved through compliance found in the National Fire Protection Association (NFPA) 70E, 2012 Edition, Section 10(b)(1) Head Protection, instructs individuals: "An arc-rated balaclava shall be used with an arc-rated face-shield when the back of the head is within the arc flash boundary." Table 130.7(C)(16) categorize the activities into risk groups, and describe protective clothing and personal protective equipment associated for each group. This criteria also provides that if the meter technicians are working with voltages over 240V, the PPE should satisfy an arc-rating of 8 cal/cm2 based on the Hazard/Risk Category2*. An arc-rated flash suit hood or arc-rated face shield and arc-rated balaclava are required for Hazard/Risk Category 2 activities.                                                   OR IN THE ALTERNATIVE   Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to burn injuries from arc flash/blast while removing or installing meters and exposed to energized electrical equipment over 240V.   (a) Corix Utilities, Inc. @ 155 E. Boardwalk Dr., Fort Collins, CO 80525: On and before January 16th, 2013, the employer did not ensure employees were protected from thermal energy hazards created by arc flash/blast during removal and installation of an electric meter. On January 16th, 2013, an employee was inserting a new AMI electrical meter into a meter socket involving 277/480V switchgear with the load and line energized when an arc flash/blast occurred. The employee received burns to the ears and head as a result. This condition exposed employees to burns associated with arc flash and arc blast incidents.      One feasible and acceptable method of abatement may be achieved through compliance found in the National Fire Protection Association (NFPA) 70E, 2012 Edition, Section 10(b)(1) Head Protection, instructs individuals: "An arc-rated balaclava shall be used with an arc-rated face-shield when the back of the head is within the arc flash boundary." Table 130.7(C)(16) categorize the activities into risk groups, and describe protective clothing and personal protective equipment associated for each group. This criteria also provides that if the meter technicians are working with voltages over 240V, the PPE should satisfy an arc-rating of 8 cal/cm2 based on the Hazard/Risk Category2*. An arc-rated flash suit hood or arc-rated face shield and arc-rated balaclava are required for Hazard/Risk Category 2 activities.
Recent events (3)
  • — F (S) $0
  • — C (S) $7000
  • — Z (S) $7000