NASHUA, NH —
OSHA Inspection: FAB-BRAZE CORPORATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of FAB-BRAZE CORPORATION in 5 PROGRESS AVE., NASHUA, NH 03062 (NAICS 331524). OSHA activity number 338692635.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FAB-BRAZE CORPORATION
- Site address
- 5 PROGRESS AVE.
- City
- NASHUA
- State
- NH
- ZIP
- 03062
- Mailing
- 5 PROGRESS AVE., NASHUA, NH 03062
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331524
- Employees
- 14
- Ownership type
- A
Citations
12 citations on file for this inspection.
5(a)(1)
- Issued
- Jun 12, 2013
- Abate by
- Jun 12, 2013
- Penalty
- Initial $4,500 · Current $2,700 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to ejection hazards. a. Site - Employees were not protected from ejection hazards when seat belts were not used while operating a Yale GLC030 forklift on non-level grades.
Recent events (2)
- — I (S) $2700
- — Z (S) $4500
1910.178 L04 III
- Issued
- Jun 12, 2013
- Abate by
- Jul 9, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: a. Site - The employer did not conduct evaluations of powered industrial truck operator's performance at least once every three years.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.132 D01
- Issued
- Jun 12, 2013
- Abate by
- Dec 2, 2013
- Penalty
- Initial $4,500 · Current $2,700 Reduced
General-duty citation text
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE): a. Site - Employees were not protected from burns when the employer failed to do a hazard assessment to determine what protective equipment was needed for molten metal pouring operations.
Recent events (2)
- — I (S) $2700
- — Z (S) $4500
1910.133 A01
- Issued
- Jun 12, 2013
- Abate by
- Jun 18, 2013
- Penalty
- Initial $6,300 · Current $3,780 Reduced
General-duty citation text
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from molten metal: Instance A- Employees were not protected from burns when adequate eye and face protection was not used or required during metal pouring operations. Instance B- Employees were not protected from burns and eye injuries when eye and face protection was not used or required while removing castings containing boiling water from a pressure vessel.
Recent events (2)
- — I (S) $3780
- — Z (S) $6300
1910.138 A
- Issued
- Jun 12, 2013
- Abate by
- Jun 12, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.138(a): The employer did not select and require employee(s) to use appropriate hand protection when employees' hands were exposed to hazards of harmful temperature extremes. a. Site - Employees were not protected from burns while operating the sealing machine which contained wax heated to approximately 225 degrees without the use of hand protection.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Jun 12, 2013
- Abate by
- Jun 18, 2013
- Penalty
- Initial $4,500 · Current $2,700 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation and ingoing nip points: Instance 1- Employees operating a Burr- King model 760 three wheel belt sander were not protected from moving parts at the point of operation when a guard was removed. Instance 2- Employees operating an Egleberg "wide belt" sander and two Burr- King model 760 three wheel belt sanders were not protected from ingoing nip points when the bottom wheels was left unguarded.
Recent events (2)
- — I (S) $2700
- — Z (S) $4500
1910.219 C03
- Issued
- Jun 12, 2013
- Abate by
- Jun 18, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(c)(3): Vertical or inclined shafting seven -7 feet or less from floor or working platform was not enclosed with a stationary casing: a. Site - Employees in the area of the "pattern wax mixer" were not protected from a rotating shaft which was not equipped with a stationary casing.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.242 B
- Issued
- Jun 12, 2013
- Abate by
- Jun 18, 2013
- Penalty
- Initial $2,700 · Current $1,620 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a. Site - Employees were not protected from injury when compressed air used to clean castings was set in excess of 55 p.s.i.
Recent events (2)
- — I (S) $1620
- — Z (S) $2700
1910.304 G06 IV A
- Issued
- Jun 12, 2013
- Abate by
- Jun 18, 2013
- Penalty
- Initial $4,500 · Current $2,700 Reduced
General-duty citation text
29 CFR 1910.304(g)(6)(iv)(A): Exposed noncurrent-carrying metal parts of fixed equipment that may become energized was not grounded when within 2.44 m (8 ft) vertically or 1.52 m (5 ft) horizontally of ground or grounded metal objects and subject to employee contact: a. Finish room- Employees were not protected from electrical shocks and burns when a metal lamp affixed to a Bridgeport drill press was not grounded.
Recent events (2)
- — I (S) $2700
- — Z (S) $4500
1910.305 B01 II
- Issued
- Jun 12, 2013
- Abate by
- Jun 12, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: Instance 1- employees were not protected from electrical shocks and burns when unused openings in an electrical cabinet located in the wax production area were not effectively closed. Instance 2- Employees were not protected from electrical shocks and burns when unused openings in an electrical cabinet located in the knockout area were not effectively closed. Instance 3- Employees were not protected from electrical shocks and burns when unused openings in an electrical cabinet located in a storage area were not effectively closed.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B02 I
- Issued
- Jun 12, 2013
- Abate by
- Jun 18, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each junction box in completed installations did not have a cover, faceplate, or fixture canopy: a. Oven- Employees were not protected from electrical shocks and burns when a junction box did not have a cover resulting in exposed wires.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G02 III
- Issued
- Jun 12, 2013
- Abate by
- Jun 18, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: a. Site - Employees were not protected from electrical shocks and burns when flexible cords were not equipped with strain relief resulting in exposed wiring.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Fab-Braze Corporation
View Fab-Braze Corporation's full OSHA safety record →
More inspections in this industry (NAICS 331524)
More inspections in NH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338692635.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.