Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ARYZTA LLC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of ARYZTA LLC. in 111 NORHWEST AVENUE, NORTHLAKE, IL 60164 (NAICS 311813). OSHA activity number 338703036.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Aryzta LLC. — free Get an email when a new federal OSHA severe-injury report for Aryzta LLC. is published. One employer, no account, unsubscribe in one click.
Establishment
ARYZTA LLC.
Site address
111 NORHWEST AVENUE
City
NORTHLAKE
State
IL
ZIP
60164
Mailing
111 NORHWEST AVENUE, NORTHLAKE, IL 60164
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311813
Employees
280
Ownership type
A

3 citations on file for this inspection.

1910.119 J02

Other-than-serious 4 instances 2 exposed
Issued
Jul 29, 2013
Abate by
Sep 13, 2013
Penalty
Initial $5,000 · Current $3,000 Reduced

Hazardous substances 0170

29 CFR 1910.119(j)(2): The employer did not establish written procedures to maintain the on-going integrity of process equipment.    (a) Aryzta LLC - The employer did not ensure the mechanical integrity program procedure listed to contain specific employer procedural steps or instructions to assure inspection frequencies for RB-1 low stage booster compressor and the RC-3 high stage screw compressor.    (b) Aryzta LLC. - The employer did not ensure the mechanical integrity program established criteria to determine when inspection testing and preventive maintenance activity frequency must increase.       (c ) Aryzta LLC. The employer did not ensure the mechanical integrity program contain specific employer procedural steps or instructions to assure the mechanical integrity of the equipment  and detail to provide the employers' inspectors (including contract inspectors) instruction on how to conduct inspections and tests of insulated and non-insulated piping to assure their mechanical integrity.      (d) Aryzta LLC. -  The employer did not ensure the mechanical integrity program contained specific detail on the specific contractors duties to maintain the ammonia refrigeration system.
Recent events (2)
  • — I (O) $3000
  • — Z (S) $5000

1910.119 J04 II

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Jul 29, 2013
Penalty
Initial $5,000 · Current $0 Reduced

Hazardous substances 0170

29 CFR 1910.119(j)(4)(ii): Inspection and testing procedures shall follow recognized and generally accepted good engineering practices.   a) Aryzta LLC. - The employer did not perform inspection and testing procedures which followed recognized and generally accepted good engineering practices. The employer did not address "slight corrosion" on piping; employer did not prime paint or refinish any rusted, pitted or corroded pipe, consistent with recognized and generally accepted good engineering practices.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5000

1910.119 D03 II

Other-than-serious 1 instance 2 exposed
Issued
Jul 29, 2013
Penalty
Initial $0 · Current $0

Hazardous substances 0170

29 CFR 1910.119(d)(3)(ii):  The employer did not document that the equipment in the process complied with recognized and generally accepted good engineering practices:   a) Aryzta LLC - The employer did not document that safety controls, for the ammonia refrigeration system including interlocks and shutdowns, were in compliance with RAGAGEP. The safety controls including but not limited to interlocks and shutdowns were not in compliance with complied with recognized and generally accepted good engineering practices such as IIAR Bulletin 110 for specific safety systems identified as safeguards in the 2011 process hazard analysis (PHA) that include but are not limited to the following:.    1.         Emergency Stop (E-Stop outside the Engine Room). 2.         High Motor Amps Cutouts. 3.         Low Suction Alarms and Cutouts. 4.         Draeger Point Guard Alarm. 5.         High Discharge Pressure Cutouts.  6.         High Discharge Temperature Cutouts.  7.         High Oil Pressure Cutouts.  8.         Low Oil Pressure Cutouts.  9.         High Oil Temperature Cutouts.  10.       Low Oil Temperature Cutouts.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Aryzta LLC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338703036.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.