PFLUGERVILLE, TX —
OSHA Inspection: AUSTIN PALLET COMPANY
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of AUSTIN PALLET COMPANY in 1605 CENTURY STREET, PFLUGERVILLE, TX 78660 (NAICS 321920). OSHA activity number 338703846.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AUSTIN PALLET COMPANY
- Site address
- 1605 CENTURY STREET
- City
- PFLUGERVILLE
- State
- TX
- ZIP
- 78660
- Mailing
- 1605 CENTURY STREET, PFLUGERVILLE, TX 78660
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321920
- Employees
- 24
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.95 G06
- Issued
- Feb 26, 2013
- Abate by
- Mar 31, 2013
- Penalty
- Initial $1,600 · Current $900 Reduced
General-duty citation text
29 CFR 1910.95(g)(6): At least annually after obtaining the baseline audiogram, the employer did not obtain a new audiogram for each employee exposed at or above an 8-hour time-weighted average of 85 decibels: On or about January 31, 2013, the employer did not provide for annual audiometric testing of employees whose exposures equal or exceed an 8-hour time-weighted average of 85 decibels, exposing employees to the hazard of permanent hearing loss. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that all employees exposed to high levels of noise receive a baseline and annual audiogram.
Recent events (2)
- — I (S) $900
- — Z (S) $1600
1910.95 G07 I
- Issued
- Feb 26, 2013
- Abate by
- Mar 31, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.95(g)(7)(i): Each employee's annual audiogram was not compared to that employee's baseline audiogram to determine if the audiogram is valid and if a standard threshold shift as defined in 29 CFR 1910.95(g)(10) has occurred: On or about January 31, 2013, the employer did not compare the employee annual and baseline audiograms to determine if a standard threshold shift had occurred, exposing employees to the hazard of permanent hearing loss. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that the employer compares the baseline and annual audiograms of employees to determine if a threshold shift has occurred.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B01 I
- Issued
- Feb 26, 2013
- Abate by
- Mar 11, 2013
- Penalty
- Initial $1,200 · Current $800 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasions: On or about January 31, 2013, conductors entering a receptacle box in the chop saw room were not protected from abrasion, exposing employees to burn and shock hazards. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that wiring entering and exiting boxes is protected from abrasion.
Recent events (2)
- — I (S) $800
- — Z (S) $1200
1910.305 G01 IV A
- Issued
- Feb 26, 2013
- Abate by
- Mar 11, 2013
- Penalty
- Initial $1,200 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: On or about January 31, 2013, a flexible cord was used as permanent wiring in the pallet repair area to power a radio, exposing employees to burn and shock hazards. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that flexible cords are not affixed to building surfaces and used as permanent wiring.
Recent events (2)
- — I (O) $0
- — Z (S) $1200
1910.305 G01 IV D
- Issued
- Feb 26, 2013
- Abate by
- Mar 11, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords and cables were used where attached to building surfaces: On or about January 31, 2013, a flexible cord was affixed to the structure in the pallet repair area to power a radio, exposing employees to burn and shock hazards. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that flexible cords are not affixed to building surfaces and used as permanent wiring.
Recent events (2)
- — I (O) $0
- — Z (S) $0
More inspections at Austin Pallet Company