Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AUSTIN PALLET COMPANY

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of AUSTIN PALLET COMPANY in 1605 CENTURY STREET, PFLUGERVILLE, TX 78660 (NAICS 321920). OSHA activity number 338703846.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Austin Pallet Company — free Get an email when a new federal OSHA severe-injury report for Austin Pallet Company is published. One employer, no account, unsubscribe in one click.
Site address
1605 CENTURY STREET
City
PFLUGERVILLE
State
TX
ZIP
78660
Mailing
1605 CENTURY STREET, PFLUGERVILLE, TX 78660
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321920
Employees
24
Ownership type
A

5 citations on file for this inspection.

1910.95 G06

Serious Gravity 5 1 instance 24 exposed
Issued
Feb 26, 2013
Abate by
Mar 31, 2013
Penalty
Initial $1,600 · Current $900 Reduced
29 CFR 1910.95(g)(6):   At least annually after obtaining the baseline audiogram, the employer did not obtain a new audiogram for each employee exposed at or above an 8-hour time-weighted average of 85 decibels:  On or about January 31, 2013, the employer did not provide for annual audiometric testing of employees whose exposures equal or exceed an 8-hour time-weighted average of 85 decibels, exposing employees to the hazard of permanent hearing loss.  Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that all employees exposed to high levels of noise receive a baseline and annual audiogram.
Recent events (2)
  • — I (S) $900
  • — Z (S) $1600

1910.95 G07 I

Serious Gravity 5 1 instance 24 exposed
Issued
Feb 26, 2013
Abate by
Mar 31, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.95(g)(7)(i):   Each employee's annual audiogram was not compared to that employee's baseline audiogram to determine if the audiogram is valid and if a standard threshold shift as defined in 29 CFR 1910.95(g)(10) has occurred:  On or about January 31, 2013, the employer did not compare the employee annual and  baseline audiograms to determine if a standard threshold shift had occurred, exposing employees to the hazard of permanent hearing loss.  Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that the employer compares the baseline and annual audiograms of employees to determine if a threshold shift has occurred.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B01 I

Serious Gravity 1 1 instance 5 exposed
Issued
Feb 26, 2013
Abate by
Mar 11, 2013
Penalty
Initial $1,200 · Current $800 Reduced
29 CFR 1910.305(b)(1)(i):   Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasions:  On or about January 31, 2013, conductors entering a receptacle box in the chop saw room were not protected from abrasion, exposing employees to burn and shock hazards.    Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that wiring entering and exiting boxes is protected from abrasion.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1200

1910.305 G01 IV A

Other-than-serious 1 instance 1 exposed
Issued
Feb 26, 2013
Abate by
Mar 11, 2013
Penalty
Initial $1,200 · Current $0 Reduced
29 CFR 1910.305(g)(1)(iv)(A):   Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  On or about January 31, 2013, a flexible cord was used as permanent wiring in the pallet repair area to power a radio, exposing employees to burn and shock hazards.	  Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that flexible cords are not affixed to building surfaces and used as permanent wiring.
Recent events (2)
  • — I (O) $0
  • — Z (S) $1200

1910.305 G01 IV D

Other-than-serious 1 instance 1 exposed
Issued
Feb 26, 2013
Abate by
Mar 11, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(D):   Flexible cords and cables were used where attached to building surfaces:  On or about January 31, 2013, a flexible cord was affixed to the structure in the pallet repair area to power a radio, exposing employees to burn and shock hazards.	  Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that flexible cords are not affixed to building surfaces and used as permanent wiring.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

View Austin Pallet Company's full OSHA safety record →