Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: COASTAL MAINE GENERAL CONTRACTING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of COASTAL MAINE GENERAL CONTRACTING, INC. in 22 SCHOOL STREET, WINTER HARBOR, ME 04693 (NAICS 238130). OSHA activity number 338715436.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Coastal Maine General Contracting, INC. — free Get an email when a new federal OSHA severe-injury report for Coastal Maine General Contracting, INC. is published. One employer, no account, unsubscribe in one click.
Site address
22 SCHOOL STREET
City
WINTER HARBOR
State
ME
ZIP
04693
Mailing
P.O. BOX 272, MACHIAS, ME 04654
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
3
Ownership type
A

7 citations on file for this inspection.

1926.405 A02 II I

Serious Gravity 10 2 instances 2 exposed
Issued
Feb 25, 2013
Abate by
Mar 5, 2013
Penalty
Initial $2,520 · Current $1,764 Reduced
29 CFR 1926.405(a)(2)(ii)(I): Flexible cords and cables shall be protected from damage.    Winter Harbor Public Safety Building - The orange and black extension cords were not protected from vehicular traffic.
Recent events (2)
  • — I (S) $1764
  • — Z (S) $2520

1926.501 B04 I

Serious Gravity 10 1 instance 2 exposed
Issued
Feb 25, 2013
Abate by
Mar 5, 2013
Penalty
Initial $2,520 · Current $1,764 Reduced
29 CFR 1926.501(b)(4)(i):   Each employee on walking/working surfaces shall be protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes.    Winter Harbor Public Safety Building - The ladder floor hole 10 feet above the concrete floor was not provided with fall protection.
Recent events (2)
  • — I (S) $1764
  • — Z (S) $2520

1926.501 B06

Serious Gravity 10 1 instance 2 exposed
Issued
Feb 25, 2013
Abate by
Mar 5, 2013
Penalty
Initial $2,520 · Current $0 Reduced
29 CFR 1926.501(b)(6):  Each employee on ramps, runways, and other walkways shall be protected from falling 6 feet (1.8 m) or more to lower levels by guardrail systems, safety net systems, or personal fall arrest systems.    Winter Harbor Public Safety Building - Employees working 10 feet above the concrete floor, on the plank walkway, were not protected from falling.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2520

1926.701 B

Serious Gravity 10 35 instances 2 exposed
Issued
Feb 25, 2013
Abate by
Mar 5, 2013
Penalty
Initial $2,520 · Current $1,764 Reduced
29 CFR 1926.701(b):   All protruding reinforcing steel, onto and into which employees could fall, shall be guarded to eliminate the hazard of impalement.    Winter Harbor Public Safety Building - Thirty-five rebar ends were not capped or guarded.
Recent events (2)
  • — I (S) $1764
  • — Z (S) $2520

1926.1051 B

Serious Gravity 10 1 instance 2 exposed
Issued
Feb 25, 2013
Abate by
Mar 5, 2013
Penalty
Initial $2,520 · Current $1,764 Reduced
29 CFR 1926.1051(b):   Employers shall provide and install all stairway and ladder fall protection systems required by this subpart and shall comply with all other pertinent requirements of this subpart before employees begin the work that necessitates the installation and use of stairways, ladders, and their respective fall protection systems.    Winter Harbor Public Safety Building - The attic ladder did not extend three feet above the upper landing surface, and a grasping device or handrail was not provided.
Recent events (2)
  • — I (S) $1764
  • — Z (S) $2520

1926.405 G02 IV

Other-than-serious 1 instance 2 exposed
Issued
Feb 25, 2013
Abate by
Mar 5, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.405(g)(2)(iv):   Flexible cords shall be connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws.    Winter Harbor Public Safety Building - The black flexible cord was not provided with strain relief.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1926.600 A03 I

Other-than-serious 1 instance 2 exposed
Issued
Feb 25, 2013
Penalty
Initial $1,080 · Current $0 Reduced
29 CFR 1926.600(a)(3)(i):  Heavy machinery, equipment, bulldozer and scraper blades, end-loader buckets, dump bodies, and similar equipment, shall be either fully lowered or blocked when being repaired or when not in use. All controls shall be in a neutral position, with the motors stopped and brakes set, unless work being performed requires otherwise.    Winter Harbor Public Safety Building - The forks and platform, on the Gradall forklift, were not fully lowered when not in use.
Recent events (2)
  • — I (O) $0
  • — Z (S) $1080

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338715436.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.