TROY, OH —
OSHA Inspection: JAYNA, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of JAYNA, INC. in 81 INDUSTRY COURT, TROY, OH 45373 (NAICS 332710). OSHA activity number 338726839.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- JAYNA, INC.
- Site address
- 81 INDUSTRY COURT
- City
- TROY
- State
- OH
- ZIP
- 45373
- Mailing
- 15 MARYBILL DRIVE, TROY, OH 45373
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332710
- Employees
- 80
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C05 I
- Issued
- Jul 24, 2013
- Abate by
- Aug 19, 2013
- Penalty
- Initial $7,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware shall be provided by the employer for isolating, securing or blocking of machines or equipment from energy sources: (a) Employees were not provided with locks or tags to attach to the energy isolating devices, prior to conducting the end-of-shift cleaning inside the Daewoo DMV-4020 Vertical Machining Center. Jayna, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1947(c)(5)(i), which was contained in OSHA inspection number 315678821, Citation Number 1, Item Number 2, and was affirmed as a final order on October 22, 2012, with respect to a workplace located at 15 Marybill Drive, Troy, Ohio 45373. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
- — I (R) $0
- — Z (R) $7000
1910.147 C07 I
- Issued
- Jul 24, 2013
- Abate by
- Aug 19, 2013
- Penalty
- Initial $7,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: (a) Employee training on the energy control program was inadequate, in that it did not include training employees on when and how to lock out the Daewoo DMV-4020 Vertical Machining Center prior to conducting the end-of-shift cleaning inside the Daewoo DMV-4020 Vertical Machining Center. Jayna, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1947(c)(7)(i), which was contained in OSHA inspection number 315678821, Citation Number 1, Item Number 4 and was affirmed as a final order on October 22, 2012, with respect to a workplace located at 15 Marybill Drive, Troy, Ohio 45373. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
- — I (R) $0
- — Z (R) $7000
1910.147 D03
- Issued
- Jul 24, 2013
- Abate by
- Aug 19, 2013
- Penalty
- Initial $7,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(d)(3): Machine or equipment isolation. All energy isolating devices that are needed to control the energy to the machine or equipment shall be physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): (a) Employees cleaned the inside of the Daewoo DMV-4020 Vertical Machining Center, at the end of the shift, without first isolating the energy sources. Jayna, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1947(d)(3), which was contained in OSHA inspection number 315678821, Citation Number 1, Item Number 5(a) and was affirmed as a final order on October 22, 2012, with respect to a workplace located at 15 Marybill Drive, Troy, Ohio 45373. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
- — I (R) $0
- — Z (R) $7000
1910.147 D04 I
- Issued
- Jul 24, 2013
- Abate by
- Aug 19, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices shall be affixed to each energy isolating device by authorized employees: (a) Employees cleaned the inside of the Daewoo DMV-4020 Vertical Machining Center, at the end of the shift, without first affixing a lockout device to the energy isolating devices. Jayna, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1947(d)(4)(i), which was contained in OSHA inspection number 315678821, Citation Number 1, Item Number 5(b) and was affirmed as a final order on October 22, 2012, with respect to a workplace located at 15 Marybill Drive, Troy, Ohio 45373. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
- — I (R) $0
- — Z (R) $0
More inspections at Jayna, INC.