Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: VOLUMATIC, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of VOLUMATIC, INC. in 8219 INDUSTRIAL HWY, MACON, GA 31216 (NAICS 336413). OSHA activity number 338739634.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Volumatic, INC. — free Get an email when a new federal OSHA severe-injury report for Volumatic, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
VOLUMATIC, INC.
Site address
8219 INDUSTRIAL HWY
City
MACON
State
GA
ZIP
31216
Mailing
8219 INDUSTRIAL HWY, MACON, GA 31216
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336413
Employees
17
Ownership type
A

5 citations on file for this inspection.

1910.147 C01

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Mar 6, 2013
Abate by
Apr 10, 2013
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    On or about 2/7/2013 at 8219 Industrial Highway Macon, Ga; where employees are exposed to hazardous energy the employer failed to provide a lockout/tagout program to employees performing lockout/ tagout on equipment with multiple energy sources including but not limited to hydraulic, pneumatic, and electrical on the three C&C machines.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2800

1910.242 B

Serious Gravity 5 2 instances 20 exposed
Issued
Mar 6, 2013
Penalty
Initial $1,700 · Current $850 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 P.S.I.:    On or about 2/7/2013 at 8219 Industrial Highway Macon, Ga; where employees use compressed air to clean metal shavings at and near the C&C machines were exposed to struck-by hazards where the air nozzles were not chip guarded and the compressed air was measured at 100 P.S.I.
Recent events (2)
  • — I (S) $850
  • — Z (S) $1700

1910.134 C02 I

Serious Gravity 5 1 instance 21 exposed
Issued
Mar 6, 2013
Abate by
Apr 10, 2013
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.134(c)(2)(i): The employer did not determine if the voluntary use of a respirator did not in itself create a hazard:    On or about 02/07/2013 at 8219 Industrial Highway Macon, Ga; where the employer has employees wearing tight-fitting, air-purifying respirators, voluntarily to protect against acetone, a written respirator program was not implemented.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1910.134 K06

Deleted Serious Gravity 1 1 instance 1 exposed
Issued
Mar 6, 2013
Abate by
Apr 10, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer:    On or about 02/07/2013 at 8219 Industrial Highway Macon, Ga; where employees are voluntarily wearing tight fitting, half mask, air purifying respirators to protect against acetone had not been provided with Appendix D of the respiratory protection standard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 E01

Serious Gravity 5 1 instance 17 exposed
Issued
Mar 6, 2013
Abate by
Apr 10, 2013
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:    On or about 2/7/2013 at 8219 Industrial Highway Macon, Ga; where the employer did not develop and implement a written hazard communication program where employees are required to work with Dykem which contains acetone.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338739634.