FAYETTEVILLE, GA —
OSHA Inspection: FRANCISCO GALVAR
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of FRANCISCO GALVAR in 3666 HWY. 54W, FAYETTEVILLE, GA 30214 (NAICS 238160). OSHA activity number 338743040.
Where did this inspection happen?
- Establishment
- FRANCISCO GALVAR
- Site address
- 3666 HWY. 54W
- City
- FAYETTEVILLE
- State
- GA
- ZIP
- 30214
- Mailing
- 2016 OLIVE SPRINGS ROAD SE APT. 2, MARIETTA, GA 30060
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 4
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.102 A01
- Issued
- Mar 12, 2013
- Abate by
- Mar 18, 2013
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents. (a) Roof, new medical facility located at 3666 Hwy. 54W, Fayetteville, GA 30214: Employees were not protected from eye injuries while operating Hitachi (Model NV45AB2) Coil Roofing Nail Guns as these pneumatic tools were operated without safety glasses.
Recent events (1)
- — Z (S) $1600
1926.501 B11
- Issued
- Mar 12, 2013
- Abate by
- Mar 18, 2013
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: (a) Roof, new medical facility located at 3666 Hwy. 54W, Fayetteville, GA 30214: Employees were exposed to fall hazards while installing shingles on a 6/12 pitched roof at heights of approximately 19' to the ground with no fall protection system in place.
Recent events (1)
- — Z (S) $2800
1926.1053 B04
- Issued
- Mar 12, 2013
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: (a) South side, new medical facility located at 3666 Hwy. 54W, Fayetteville, GA 30214: Employees were exposed to falls of approximately 12' while using a TranzSporter (LH200) Platform Hoist Ladder as a means of access to the roof. The manufacturer of this ladder states that it should not be used as a personnel ladder as the first 4 rungs of the ladder are obstructed by the loading platform and a metal cable runs through the middle of the ladder.
Recent events (1)
- — Z (S) $2000
More inspections in this industry (NAICS 238160)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338743040.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.