Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: IEC ELECTRONICS CORPORATION

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of IEC ELECTRONICS CORPORATION in 105 NORTON STREET, NEWARK, NY 14513 (NAICS 334412). OSHA activity number 338744055.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch IEC Electronics Corporation — free Get an email when a new federal OSHA severe-injury report for IEC Electronics Corporation is published. One employer, no account, unsubscribe in one click.
Site address
105 NORTON STREET
City
NEWARK
State
NY
ZIP
14513
Mailing
105 NORTON STREET, NEWARK, NY 14513
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
334412
Employees
650
Ownership type
A

5 citations on file for this inspection.

1910.1025 H01

Other-than-serious 3 instances 100 exposed
Issued
Apr 22, 2013
Abate by
May 25, 2013
Penalty
Initial $2,550 · Current $0 Reduced
29 CFR 1910.1025(h)(1): All surfaces were not maintained as free as practicable of accumulations of lead:     a) Running wave soldering area, on or about 2/13/13: The surface of computer station of  an employee engaged in wave soldering was contaminated with 341 micrograms of lead.     b) Printing station, Line 1, on or about 2/13/13: The surface of printing station table was contaminated with 548.5 micrograms of lead.     c) Wave soldering station, on or 2/13/13: The surface of the wave soldering work station was contaminated with 22.1 micrograms of lead.     Abatement certification must be submitted for this item.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2550

1910.1025 H02 I

Other-than-serious 3 instances 100 exposed
Issued
Apr 22, 2013
Abate by
May 25, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1025(h)(2)(i): Floors and/or other surfaces where lead accumulates were cleaned by the use of compressed air:      a) Throughout the facility, on or about 2/13/13: Compressed air was used to clean surfaces contaminated with lead including, but not limited to, the line 1 printing station table. The table was contaminated with 548.5 micrograms of lead.      Abatement certification must be submitted for this item.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.1025 L01 I

Serious Gravity 1 1 instance 100 exposed
Issued
Apr 22, 2013
Abate by
May 25, 2013
Penalty
Initial $0 · Current $1,785
29 CFR 1910.1025(l)(1)(i): Employee(s) working in an area where there is potential exposure to airborne lead at any level were not informed of the content of Appendices A and B of 29 CFR 1910.1025:    a) Throughout the facility, on or about 2/13/13: Training on appendices A and B of the Lead standard, 29 CFR 1910.1025 was not provided for employees exposed to airborne lead at any level. A wave solderer was exposed to lead at .0043 milligrams per cubic meter during the 350 minute sampling period. A zero increment was included for the 130 minutes not sampled.    Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $1785
  • — Z (S) $0

1910.1025 L01 II

Other-than-serious 3 instances 100 exposed
Issued
Apr 22, 2013
Abate by
May 25, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1025(l)(1)(ii): The employer did not train each employee who is subject to exposure to lead at or above the action level, or for whom the possibility of skin or eye irritation exists, in accordance with the requirements of 29 CFR 1910.1025:     a) Throughout the facility, on or about 2/13/13: Training on lead was not provided for employees for whom the possibility of eye irritation exists while using compressed air to clean surfaces contaminated with lead including, but not limited to, the line 1 printing station table. The table was contaminated with 548.5 micrograms of lead.       Abatement certification must be submitted for this item.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.147 C04 I

Other-than-serious 1 instance 10 exposed
Issued
Apr 22, 2013
Abate by
Aug 1, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:      a) Throughout the facility, on or about 2/13/13: Energy control procedures were not documented for equipment with multiple energy sources including, but not limited to, ovens and  XPM Reflow Soldering Systems both  utilzing  electrical, thermal and pneumatic energy.      Abatement certification must be submitted for this item.