NEWARK, NY —
OSHA Inspection: IEC ELECTRONICS CORPORATION
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of IEC ELECTRONICS CORPORATION in 105 NORTON STREET, NEWARK, NY 14513 (NAICS 334412). OSHA activity number 338744055.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- IEC ELECTRONICS CORPORATION
- Site address
- 105 NORTON STREET
- City
- NEWARK
- State
- NY
- ZIP
- 14513
- Mailing
- 105 NORTON STREET, NEWARK, NY 14513
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 334412
- Employees
- 650
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.1025 H01
- Issued
- Apr 22, 2013
- Abate by
- May 25, 2013
- Penalty
- Initial $2,550 · Current $0 Reduced
General-duty citation text
29 CFR 1910.1025(h)(1): All surfaces were not maintained as free as practicable of accumulations of lead: a) Running wave soldering area, on or about 2/13/13: The surface of computer station of an employee engaged in wave soldering was contaminated with 341 micrograms of lead. b) Printing station, Line 1, on or about 2/13/13: The surface of printing station table was contaminated with 548.5 micrograms of lead. c) Wave soldering station, on or 2/13/13: The surface of the wave soldering work station was contaminated with 22.1 micrograms of lead. Abatement certification must be submitted for this item.
Recent events (2)
- — I (O) $0
- — Z (S) $2550
1910.1025 H02 I
- Issued
- Apr 22, 2013
- Abate by
- May 25, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1025(h)(2)(i): Floors and/or other surfaces where lead accumulates were cleaned by the use of compressed air: a) Throughout the facility, on or about 2/13/13: Compressed air was used to clean surfaces contaminated with lead including, but not limited to, the line 1 printing station table. The table was contaminated with 548.5 micrograms of lead. Abatement certification must be submitted for this item.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.1025 L01 I
- Issued
- Apr 22, 2013
- Abate by
- May 25, 2013
- Penalty
- Initial $0 · Current $1,785
General-duty citation text
29 CFR 1910.1025(l)(1)(i): Employee(s) working in an area where there is potential exposure to airborne lead at any level were not informed of the content of Appendices A and B of 29 CFR 1910.1025: a) Throughout the facility, on or about 2/13/13: Training on appendices A and B of the Lead standard, 29 CFR 1910.1025 was not provided for employees exposed to airborne lead at any level. A wave solderer was exposed to lead at .0043 milligrams per cubic meter during the 350 minute sampling period. A zero increment was included for the 130 minutes not sampled. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $1785
- — Z (S) $0
1910.1025 L01 II
- Issued
- Apr 22, 2013
- Abate by
- May 25, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1025(l)(1)(ii): The employer did not train each employee who is subject to exposure to lead at or above the action level, or for whom the possibility of skin or eye irritation exists, in accordance with the requirements of 29 CFR 1910.1025: a) Throughout the facility, on or about 2/13/13: Training on lead was not provided for employees for whom the possibility of eye irritation exists while using compressed air to clean surfaces contaminated with lead including, but not limited to, the line 1 printing station table. The table was contaminated with 548.5 micrograms of lead. Abatement certification must be submitted for this item.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.147 C04 I
- Issued
- Apr 22, 2013
- Abate by
- Aug 1, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Throughout the facility, on or about 2/13/13: Energy control procedures were not documented for equipment with multiple energy sources including, but not limited to, ovens and XPM Reflow Soldering Systems both utilzing electrical, thermal and pneumatic energy. Abatement certification must be submitted for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 334412)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338744055.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.