FAYETTEVILLE, GA —
OSHA Inspection: GONZALEZ DRYWALL & GENERAL CONSTRUCTION INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of GONZALEZ DRYWALL & GENERAL CONSTRUCTION INC. in 285 LEGENDS DRIVE, FAYETTEVILLE, GA 30214 (NAICS 238310). OSHA activity number 338764632.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GONZALEZ DRYWALL & GENERAL CONSTRUCTION INC.
- Site address
- 285 LEGENDS DRIVE
- City
- FAYETTEVILLE
- State
- GA
- ZIP
- 30214
- Mailing
- 650 SINGING HILLS COURT, ROSWELL, GA 30076
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238310
- Employees
- 6
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.300 B02
- Issued
- Mar 29, 2013
- Abate by
- Apr 10, 2013
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.300(b)(2): Moving part(s) of equipment exposed to contact by employees or which otherwise created a hazard, were not guarded: (a) Front side, new residential construction located at 285 Legends Drive, Fayetteville, GA 30214: Employees were exposed to amputation hazards while operating a Generac Centurion 3250 (Model 6104-0) Generator which had a missing guard over the starter recoil exposing employees to moving parts. A makeshift canvas orange strap was used to start the generator in place of the broken pull start at which time employees were exposed to moving parts.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1926.405 A02 II I
- Issued
- Mar 29, 2013
- Penalty
- Initial $1,200 · Current $720 Reduced
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(I): Protection was not provided to avoid damage to flexible cords and cables used for temporary wiring which passed through doorways or other pinch points: (a) Front door, new residential construction located at 285 Legends Drive, Fayetteville, GA 30214: Employees using flexible cords to provide power to drywall drills failed to protect the cords from being pinched between the door and the metal threshold (saddle) exposing employees to electrical shock hazards.
Recent events (2)
- — I (S) $720
- — Z (S) $1200
1926.501 B01
- Issued
- Mar 29, 2013
- Abate by
- Apr 4, 2013
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. (a) Second floor, new residential construction located at 285 Legends Drive, Fayetteville, GA 30214: Employees installing drywall on the second floor in close proximity to the stairway and foyer were exposed to falls of approximately 11' 3" to the floor below when a guard rail system was not provided.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1926.1052 C01 II
- Issued
- Mar 29, 2013
- Abate by
- Apr 4, 2013
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge: (a) Stairway, new residential construction located at 285 Legends Drive, Fayetteville, GA 30214: Employees used a stairway with no stair rails to access the second floor exposing employees to falls to lower levels. The stairway was 18 risers high with the top landing height at approximately 11'3" from the ground below.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
More inspections at Gonzalez Drywall & General Construction INC.
View Gonzalez Drywall & General Construction INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238310)