KAPOLEI, HI —
OSHA Inspection: REFRIGERANT RECYCLING, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of REFRIGERANT RECYCLING, INC. in 91-220 KOMOHANA STREET, KAPOLEI, HI 96707 (NAICS 562920). OSHA activity number 338770035.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- REFRIGERANT RECYCLING, INC.
- Site address
- 91-220 KOMOHANA STREET
- City
- KAPOLEI
- State
- HI
- ZIP
- 96707
- Mailing
- 91-220 KOMOHANA STREET, KAPOLEI, HI 96707
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 562920
- Employees
- 30
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.22 A01
- Issued
- Mar 18, 2013
- Abate by
- Apr 20, 2013
- Penalty
- Initial $2,800 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition: (a) At Refrigerant Recycling, Inc. on or about February 8, 2013 the elevated surfaces in the front room in the AC draining area and in the finished unit loading area were not kept clear of the accumulation of explosive dust.
Recent events (2)
- — I (S) $2100
- — Z (S) $2800
1910.134 E01
- Issued
- Mar 18, 2013
- Abate by
- Apr 20, 2013
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (a) At Refrigerant Recycling, Inc. employees were provided and required to wear respirators due to the dust generated when handling appliances, but the employees were not given a medical evaluation to determine their ability to use the respirator.
Recent events (2)
- — I (S) $0
- — Z (S) $2800
1910.178 Q01
- Issued
- Mar 18, 2013
- Abate by
- Mar 28, 2013
- Penalty
- Initial $2,100 · Current $1,575 Reduced
General-duty citation text
29 CFR 1910.178(q)(1): Any power-operated industrial truck not in safe operating condition was not taken out of service, and/or repairs were not made by authorized personnel: (a) At Refrigerant Recycling, Inc. on or about February 8, 2013 the Komatsu fork truck model FG30HT-16, serial number 214678A was not removed from service when repairs were needed. The brake pedal was missing the anti slip brake pad cover.
Recent events (2)
- — I (S) $1575
- — Z (S) $2100
1910.253 B02 II
- Issued
- Mar 18, 2013
- Abate by
- Mar 28, 2013
- Penalty
- Initial $3,500 · Current $2,625 Reduced
General-duty citation text
29 CFR 1910.253(b)(2)(ii): Assigned storage spaces for cylinders was not located away from elevators, stairs, or gangways where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons: (a) At Refrigerant Recycling, Inc. compressed gas cylinders were left standing unprotected along aisles in the same areas where fork trucks were operated and subject to being knocked over or damaged; and (b) At Refrigerant Recycling, Inc. compressed gas cylinders were stacked one on top of the other without anchoring and subject to being knocked over or damaged.
Recent events (2)
- — I (S) $2625
- — Z (S) $3500
1910.305 B01 II
- Issued
- Mar 18, 2013
- Abate by
- Mar 28, 2013
- Penalty
- Initial $2,100 · Current $1,575 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: (a) At Refrigerant Recycling, Inc. on or about February 8, 2013 an electrical panel box located in the "F" Storage Area had two openings on the side of the boxe that were not effectively closed; (b) At Refrigerant Recycling, Inc. on or about February 8, 2013 an octagon box on the wall in the reclaim area had a 3/4" diameter opening on the side of the box that was not effectively closed; and (c) At Refrigerant Recycling, Inc. on or about February 8, 2013 a panel box in the Oil Contamination Area on the wall had an opening on top 1 1/2 inches in diameter that was not effectively closed.
Recent events (2)
- — I (S) $1575
- — Z (S) $2100
More inspections at Refrigerant Recycling, INC.
View Refrigerant Recycling, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 562920)
More inspections in HI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338770035.