WEATHERFORD, TX —
OSHA Inspection: NATIONAL SHOT PEENING, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NATIONAL SHOT PEENING, INC. in 1020B EAST COLUNCIA STREET, WEATHERFORD, TX 76086 (NAICS 332710). OSHA activity number 338770266.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NATIONAL SHOT PEENING, INC.
- Site address
- 1020B EAST COLUNCIA STREET
- City
- WEATHERFORD
- State
- TX
- ZIP
- 76086
- Mailing
- 1020 EAST COLUMBIA STREET STE B., WEATHERFORD, TX 76086
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332710
- Employees
- 11
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.23 C01
- Issued
- Apr 11, 2013
- Abate by
- May 7, 2013
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards: a) On or about February 8, 2013, the 10ft high overhead storage area was not equipped with standard railings, exposing employees to the hazard of falling approximately 10 feet to lower levels.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1910.178 L01 I
- Issued
- Apr 11, 2013
- Abate by
- May 7, 2013
- Penalty
- Initial $2,400 · Current $1,440 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): a) On or about February 8, 2013, in the shipping department, the employees driving the Hyundai 9000 pound forklift, were not trained, exposing employees to the hazard of being struck by the lift.
Recent events (2)
- — I (S) $1440
- — Z (S) $2400
1910.184 H05 III
- Issued
- Apr 11, 2013
- Abate by
- May 7, 2013
- Penalty
- Initial $2,400 · Current $1,440 Reduced
General-duty citation text
29 CFR 1910.184(h)(5)(iii): Natural or synthetic fiber rope sling(s) with broken or cut fibers were not immediately removed from service: a) On or about February 8, 2013, in the Maintenance Department, the employees were using a 3 foot wide Tuffy synthetic fiber sling that was severely cut and frayed, exposing employees to the hazard of being struck by the load.
Recent events (2)
- — I (S) $1440
- — Z (S) $2400
1910.215 B09
- Issued
- Apr 11, 2013
- Abate by
- May 7, 2013
- Penalty
- Initial $1,600 · Current $960 Reduced
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: a) On or about February 8, 2013, in the maintenance department, no tongue guards were provided on the Delta Shop Master bench grinder, exposing employees to the hazard of being struck by the wheel.
Recent events (2)
- — I (S) $960
- — Z (S) $1600
1910.303 G01 I
- Issued
- Apr 11, 2013
- Abate by
- May 7, 2013
- Penalty
- Initial $1,600 · Current $960 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(i): Work space was less than 30 inches wide in front of electric equipment operating at 600 volts, nominal, or less: a) On or about February 8, 2013, in the maintenance department, the electrical control panels did not have a 3 foot clearance. The electrical control panels were blocked by large tool boxes, a storage container, and a dryer.
Recent events (2)
- — I (S) $960
- — Z (S) $1600
1910.1200 E01
- Issued
- Apr 11, 2013
- Abate by
- May 7, 2013
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a) On or about February 8, 2013, there was no hazard communications program developed or maintained, when employees are using chemicals such as, but not limited to, PowerKleen rust inhibitor and MEK, exposing employees to the hazard of skin irritations.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
More inspections in this industry (NAICS 332710)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338770266.