MISSOULA, MT —
OSHA Inspection: QUALITY COMPONENTS CONSTRUCTION, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of QUALITY COMPONENTS CONSTRUCTION, INC. in 155 NORTH CALIFORNIA, MISSOULA, MT 59801 (NAICS 236220). OSHA activity number 338783632.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- QUALITY COMPONENTS CONSTRUCTION, INC.
- Site address
- 155 NORTH CALIFORNIA
- City
- MISSOULA
- State
- MT
- ZIP
- 59801
- Mailing
- P.O. BOX 41052, PINESDALE, MT 59801
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 12
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.102 A01
- Issued
- Apr 11, 2013
- Abate by
- May 7, 2013
- Penalty
- Initial $2,000 · Current $1,400 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): Employees were not provided with eye and face protection equipment when machines or operations present potential eye or face injury from physical, chemical, or radiation agents: (a) Construction Site: On or about February 5, 2013, and at times prior thereto, employees were exposed to eye injuries while using pneumatic strip nail gun to secure walls to frame. (b) Construction Site: On or about February 5, 2013, and at times prior thereto, employees were exposed to eye injuries while using Skilsaw hand held power saw to cut material.
Recent events (2)
- — I (S) $1400
- — Z (S) $2000
1926.403 B02
- Issued
- Apr 11, 2013
- Abate by
- May 7, 2013
- Penalty
- Initial $1,200 · Current $840 Reduced
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: a) East Wall: On or about February 5, 2013, and at times prior thereto, the employer utilized a four plex box as an extension cord. b) Inside Apartment Complex: On or about February 5, 2013, and at times prior thereto, the employer utilized a four plex box as an extension cord.
Recent events (2)
- — I (S) $840
- — Z (S) $1200
1926.404 B01 III C
- Issued
- Apr 11, 2013
- Abate by
- May 7, 2013
- Penalty
- Initial $1,200 · Current $840 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(iii)(C): Each cord set, attachment cap, plug and receptacle of cord sets, and any equipment connected by cord and plug, except cord sets and receptacles which are fixed and not exposed to damage, was not visually inspected before each day's use for external defects, such as deformed or missing pins or insulation damage, and for indications of possible internal damage: a) Interior East Side Apartment Complex: On or about February 5, 2013, and at times prior thereto, the employer failed to inspect the SKILSAW Worm Drive Saw for damaged or removed ground prong. b) Interior South Side Apartment Complex: On or about February 5, 2013, and at times prior thereto, the employer failed to inspect the SKILSAW Worm Drive Saw for damaged or removed ground prong.
Recent events (2)
- — I (S) $840
- — Z (S) $1200
1926.405 G02 III
- Issued
- Apr 11, 2013
- Abate by
- May 7, 2013
- Penalty
- Initial $1,200 · Current $840 Reduced
General-duty citation text
29 CFR 1926.405(g)(2)(iii): Flexible cords were not used only in continuous lengths without splice or tap. Hard service flexible cords No. 12 or larger may be repaired if spliced so that the splice retains the insulation, outer sheath properties, and usage characteristics of the cord being spliced: a) Construction Site: On or about February 5, 2013, and at times prior thereto, employees exposed to electric shock while using flexible cords with damaged insulation.
Recent events (2)
- — I (S) $840
- — Z (S) $1200
1926.405 G02 IV
- Issued
- Apr 11, 2013
- Abate by
- May 7, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws: a) Interior East Side Apartment Complex: On or about February 5, 2013, and at times prior thereto, employees exposed to electric shock while using extension cords with lack of strain relief. b) Interior South Side Apartment Complex: On or about February 5, 2013, and at times prior thereto, employees exposed to electric shock while using extension cords with lack of strain relief.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Quality Components Construction, INC.
View Quality Components Construction, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 236220)
More inspections in MT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338783632.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.