LEMONT, IL —
OSHA Inspection: SALCO PRODUCTS, INC.
Programmed Related inspection · Safety discipline
At a glance
On , OSHA opened a programmed Related safety inspection of SALCO PRODUCTS, INC. in 1385 W. 101ST ST. SUITE A, LEMONT, IL 60439 (NAICS 332999). OSHA activity number 338787633.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SALCO PRODUCTS, INC.
- Site address
- 1385 W. 101ST ST. SUITE A
- City
- LEMONT
- State
- IL
- ZIP
- 60439
- Mailing
- 1385 W. 101ST ST. SUITE A, LEMONT, IL 60439
What kind of inspection was it?
- Inspection type
- Programmed Related (J)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 111
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.147 C04 I
- Issued
- Jun 27, 2013
- Abate by
- Aug 14, 2013
- Penalty
- Initial $4,500 · Current $2,250 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section. Note: Exception: The employer need not document the required procedure for a particular machine or equipment, when all of the following elements exist: (1) The machine or equipment has no potential for stored or residual energy or reaccumulation of stored energy after shut down which could endanger employees; (2) the machine or equipment has a single energy source which can be readily identified and isolated; (3) the isolation and locking out of that energy source will completely deenergize and deactivate the machine or equipment; (4) the machine or equipment is isolated from that energy source and locked out during servicing or maintenance; (5) a single lockout device will achieve a locker-out condition; (6) the lockout device is under the exclusive control of the authorized employee performing the servicing or maintenance; (7) the servicing or maintenance does not create hazards for other employees; and (8) the employer, in utilizing this exception, has had no accidents involving the unexpected activation or reenergization of the machine or equipment during servicing or maintenance. Shop area- On or about February 8, 2013, the written lockout program did not include specific procedures for locking out all energy sources on the Romi 27 CNC Mill, DoAll horizontal bandsaw, Bace trash compactor and other operationg equipment. Employees wee thereby exposed to serious injuries.
Recent events (2)
- — I (S) $2250
- — Z (S) $4500
1910.147 C06 I
- Issued
- Jun 27, 2013
- Abate by
- Aug 14, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed. Shop area - On or about February 8, 2013, in the facility employees were reguird to perform lockout/tagout. The employer did not conduct a periodic inspection of energy control procedures at least annually to ensure that the procedures and the requirements of the standard were breing followed.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C07 I
- Issued
- Jun 27, 2013
- Abate by
- Aug 14, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees. Shop area - On or about February 8, 2013, the employer failed to ensure that adequate training was provided for every authorized, affected and other employees who work on or near the Romi CNC mill, Jet lathe, Do Alll horziontal bandsaw, and other operating equipment.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Jun 27, 2013
- Abate by
- Aug 14, 2013
- Penalty
- Initial $6,300 · Current $3,150 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Shop area - On or about February 8, 2013, employees were exposed to unguarded chucks on CNC mills and lathes. Employees are exposing to injuries associated with rotating moving parts. 1. Romi CNC Mill M27 - Serial #016007768-405 2. Romi CNC Mill M17 - 3. Harrison 13 lathe 4. Jet ser. # GH26802H & Jet ser.# GH1440ZX lathes Shop area - On or about February 8, 2013, the unused portion of the blade on the following metal cutting bandsaws were not completely guarded, therby exposing employees to the hazards of rotating saw blades. 1. Well vertical band saw 2. Work a Matic vertical band saw 3. DoAll horiziontal band saw
Recent events (2)
- — I (S) $3150
- — Z (S) $6300
1910.215 B09
- Issued
- Jun 27, 2013
- Penalty
- Initial $2,700 · Current $1,350 Reduced
General-duty citation text
29 CFR 1910.215(b)(9): Exposure adjustment. Safety guards of the types described in Subparagraphs (3) and (4) of this paragraph, where the operator stands in front of the opening, shall be constructed so that the peripheral protecting member can be adjusted to the constantly decreasing diameter of the wheel. The maximum angular exposure above the horizontal plane of the wheel spindle as specified in paragraphs (b)(3) and (4) of this section shall never be exceeded, and the distance between the wheel periphery and the adjustable tongue or the end of the peripheral member at the top shall never exceed one-fourth inch. (See Figures O-18, O-19, O-20, O-21, O-22, and O-23.) a. Shop area - On or about February 8, 2013, the pedestal Dayton grinder did not have a tongue guard for the left side grinding wheel, thereby exposing employees to the hazards of flying particles in the event the grinding wheel shattered. b. Shop area - On or about February 8, 2013, the pedestal Ryobi grinder did not have the right side tongue guard adjusted to the grinding wheel, thereby exposing employees to the hazardof flying particles in the event the wheel shattered.
Recent events (2)
- — I (S) $1350
- — Z (S) $2700
1910.305 J04 VI
- Issued
- Jun 27, 2013
- Abate by
- Aug 14, 2013
- Penalty
- Initial $4,500 · Current $2,250 Reduced
General-duty citation text
29 CFR 1910.305(j)(4)(vi): An individual disconnecting means shall be provided for each motor, but a single disconnecting means may be used for a group of motors under any one of the following conditions: Shop area - On or about February 8, 2013, electrical disconnect was not provided to isolate the energy sources to the Bace baler, thereby exposing employees to unexpected energization.
Recent events (2)
- — I (S) $2250
- — Z (S) $4500
1910.178 M10
- Issued
- Jun 27, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(m)(10): A load backrest extension shall be used whenever necessary to minimize the possibility of the load or part of it from falling rearward. Shop area - On or about February 8, 2013, the Hyster #2 and TCM forklift trucks were operated with no load backrest extension. Employees were thereby exposed to material falling backward.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G02 III
- Issued
- Jun 27, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables shall be connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws. Shop area - On or about February 8, 2013, the electrical cord to the Work O Matic vertical bandsaw was not completely guarded, in that the outer insulation was pulled away, thereby exposing employees to engergized conducters.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Salco Products, INC.
View Salco Products, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332999)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338787633.