YIGO, GU ·
OSHA Inspection: SMART CONSTRUCTION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SMART CONSTRUCTION in LOT NO. 10117-4, YIGO, GU 96929 (NAICS 238210). OSHA activity number 338796832.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SMART CONSTRUCTION
- Site address
- LOT NO. 10117-4
- City
- YIGO
- State
- GU
- ZIP
- 96929
- Mailing
- P.O. BOX 23126 GMF, BARRIGADA, GU 96921
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- Employees
- 3
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
1926.404 B01 I
- Issued
- Mar 5, 2013
- Abate by
- Mar 15, 2013
- Penalty
- Initial $1,080 · Current $810 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. (a) On or about February 12, 2013, there was no ground-fault circuit-interrupter protection or an assured equipment grounding conductor program when extension cords were used to power a 110 VAC Makita circular saw. Employees used the saws to cut lumber and rebar.
Recent events (2)
- · I (S) $810
- · Z (S) $1080
1926.405 B02
- Issued
- Mar 5, 2013
- Abate by
- Mar 11, 2013
- Penalty
- Initial $1,080 · Current $810 Reduced
General-duty citation text
29 CFR 1926.405(b)(2): In an energized installation, each outlet box did not have a cover, faceplate, or fixture canopy. (a) At the project site on or about February 12, 2013, there was no cover/face plate on the outlet that powered extension cords used to power a 110 VAC Makita circular saw, model 5007N and Makita portable cut off saw, model 2416S.
Recent events (2)
- · I (S) $810
- · Z (S) $1080
1926.405 G02 IV
- Issued
- Mar 5, 2013
- Abate by
- Mar 11, 2013
- Penalty
- Initial $1,080 · Current $810 Reduced
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: (a) At the project on or about February 12, 2013 and at times prior thereto, the outer insulation of the Makita cut off saw, model 2416S, was not secured to the plug. Employees used the cut off saw to cut rebar.
Recent events (2)
- · I (S) $810
- · Z (S) $1080
1926.651 J02
- Issued
- Mar 5, 2013
- Abate by
- Mar 15, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.651(j)(2): Employees shall be protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations. Protection shall be provided by placing and keeping such materials or equipment at least 2 feet (.61 m) from the edge of excavations, or by the use of retaining devices that are sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary. (a) At the project on or about February 12, 2013 and at times prior thereto, employees were not protected against excavated materials that could pose a hazard by falling or rolling into the trench. Spoil material was not placed at least 2 feet away from the edge of the trench.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at Smart Construction
View Smart Construction's full OSHA safety record →
More inspections in this industry (NAICS 238210)
More inspections in GU
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 338796832.