CONROE, TX —
OSHA Inspection: H & B CONSTRUCTION, LTD.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of H & B CONSTRUCTION, LTD. in 712 MCCALEB ST, CONROE, TX 77304 (NAICS 237130). OSHA activity number 338802630.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- H & B CONSTRUCTION, LTD.
- Site address
- 712 MCCALEB ST
- City
- CONROE
- State
- TX
- ZIP
- 77304
- Mailing
- P.O. BOX 30, MONTGOMERY, TX 77356
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237130
- Employees
- 5
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.651 C02
- Issued
- Feb 22, 2013
- Abate by
- Feb 26, 2013
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: The employer does ensure a safe means of egress is located so that no more than 25 feet of lateral travel is required for employee egress while working in excavations that are four feet or more in depth. This violation was observed on or about February 08, 2013, when employees working in an excavation were exposed to fall hazards while climbing in and out of an excavation without safe egress located so that no more than 25 feet of lateral travel would be required. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that employees are provided with safe means of egress located so that no more than 25 feet of travel is required while working in excavations that are four feet or more in depth.
Recent events (2)
- — I (S) $600
- — Z (S) $1200
1926.651 J02
- Issued
- Feb 22, 2013
- Abate by
- Feb 26, 2013
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary: The employer does not ensure that excavated material is placed at least 2 feet from the edge of the excavation or retained to prevent employee injury. This violation was observed on or about February 08, 2013, when employees working in an excavation were exposed to struck-by hazards from the excavated material that was not retained or placed at least 2 feet from the excavation edge. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that excavated and other material are placed at least two feet from the edge of the excavation and/or they use retaining devices to prevent materials or equipment from falling or rolling into excavations.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1926.652 A01
- Issued
- Feb 22, 2013
- Abate by
- Feb 26, 2013
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 paragraph (b) or (c): The employer does not ensure that employees are protected from cave-ins while working in excavations. This violation was observed on or about February 08, 2013, when employees were exposed to cave-in hazards while working in an excavation that was not sloped, benched or shored. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that all excavations that employees are required to work in are either sloped, benched, or shored on all sides of the of the excavation in accordance with 29 CFR 1926.652 paragraph (b) and/or (c) to prevent possible cave-ins.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
More inspections in this industry (NAICS 237130)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338802630.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.