Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DAMRON AUTO PARTS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DAMRON AUTO PARTS in 7298 WAELTI DR, MELBOURNE, FL 32940 (NAICS 425120). OSHA activity number 338805831.

Watch Damron Auto Parts — free Get an email when a new federal OSHA severe-injury report for Damron Auto Parts is published. One employer, no account, unsubscribe in one click.
Establishment
DAMRON AUTO PARTS
Site address
7298 WAELTI DR
City
MELBOURNE
State
FL
ZIP
32940
Mailing
7298 WAELTI DR, MELBOURNE, FL 32940
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
425120
Employees
104
Ownership type
A

3 citations on file for this inspection.

5(a)(1)

Serious Gravity 1 1 instance 104 exposed
Issued
Abate by
Penalty
Initial $2250.00 · Current $1350.00 Reduced
OSH ACT of 1970 Section (5)(a)(1):   The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a hazard of being struck by fragments of Thermoplastic Polyvinyl Chloride (PVC) plastic pipe ruptures.   At the establishment, PVC schedule 40 plastic pipe was used in exposed above ground locations to transport compressed air for the operation of air-operated tools.
Recent events (2)
  • — I (S) $1350
  • — Z (S) $2250

1910.219 E03 I

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2250.00 · Current $1350.00 Reduced
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o)  a) In the Cut Pad area - the nip points between the power transition pulleys and the belt on the primary air compressor, Ingensoll Rand model 1ST, serial number 30T - 728742 and the backup air compressor, products incorporated, model ACP.C66, serial number 104D6078 or not fully guarded, exposing employees to hazards associated with nip points, on or about February 6 2013.
Recent events (2)
  • — I (S) $1350
  • — Z (S) $2250

1910.304 A02

Serious Gravity 5 2 instances 10 exposed
Issued
Abate by
Penalty
Initial $2550.00 · Current $1530.00 Reduced
29 CFR 1910.304(a)(2):   Grounded conductors were attached to terminals or leads so as to reverse designated polarity:  a) In the maintenance shop  employees using a Challenger left, model 37000 and serial number 371150, were exposed to electrical hazards in that the electrical system had reversed polarity, observed on or about February the sixed 2013.  b) In the dismantle shop  employees using a Router left, model SPOA1ON700  and serial number CRZ07J0139, were exposed to electrical hazards in that the electrical system had reversed polarity, observed on or about February the sixed 2013.
Recent events (2)
  • — I (S) $1530
  • — Z (S) $2550

View DAMRON AUTO PARTS's full OSHA safety record →