MELBOURNE, FL —
OSHA Inspection: DAMRON AUTO PARTS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DAMRON AUTO PARTS in 7298 WAELTI DR, MELBOURNE, FL 32940 (NAICS 425120). OSHA activity number 338805831.
Where did this inspection happen?
- Establishment
- DAMRON AUTO PARTS
- Site address
- 7298 WAELTI DR
- City
- MELBOURNE
- State
- FL
- ZIP
- 32940
- Mailing
- 7298 WAELTI DR, MELBOURNE, FL 32940
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 425120
- Employees
- 104
- Ownership type
- A
Citations
3 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $2250.00 · Current $1350.00 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a hazard of being struck by fragments of Thermoplastic Polyvinyl Chloride (PVC) plastic pipe ruptures. At the establishment, PVC schedule 40 plastic pipe was used in exposed above ground locations to transport compressed air for the operation of air-operated tools.
Recent events (2)
- — I (S) $1350
- — Z (S) $2250
1910.219 E03 I
- Issued
- Abate by
- Penalty
- Initial $2250.00 · Current $1350.00 Reduced
General-duty citation text
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o) a) In the Cut Pad area - the nip points between the power transition pulleys and the belt on the primary air compressor, Ingensoll Rand model 1ST, serial number 30T - 728742 and the backup air compressor, products incorporated, model ACP.C66, serial number 104D6078 or not fully guarded, exposing employees to hazards associated with nip points, on or about February 6 2013.
Recent events (2)
- — I (S) $1350
- — Z (S) $2250
1910.304 A02
- Issued
- Abate by
- Penalty
- Initial $2550.00 · Current $1530.00 Reduced
General-duty citation text
29 CFR 1910.304(a)(2): Grounded conductors were attached to terminals or leads so as to reverse designated polarity: a) In the maintenance shop employees using a Challenger left, model 37000 and serial number 371150, were exposed to electrical hazards in that the electrical system had reversed polarity, observed on or about February the sixed 2013. b) In the dismantle shop employees using a Router left, model SPOA1ON700 and serial number CRZ07J0139, were exposed to electrical hazards in that the electrical system had reversed polarity, observed on or about February the sixed 2013.
Recent events (2)
- — I (S) $1530
- — Z (S) $2550
More inspections at DAMRON AUTO PARTS
ROCKLEDGE, FL—2004-08-05 00:00:00
DAMRON AUTO PARTS
View DAMRON AUTO PARTS's full OSHA safety record →
More inspections in this industry (NAICS 425120)
SAINT PAUL, MN—2026-05-18
111267 - ANCHOR PAPER COMPANY
CARSON, CA—2026-05-12
ANCON MARINE INC
OLYMPIA, WA—2026-05-06
WA317991082 - MEMORIAL MONUMENTS & VAULTS INC
OCOEE, FL—2026-04-22
COX AUTOMOTIVE, LLC
OCOEE, FL—2026-04-10
COX AUTOMOTIVE, LLC
More inspections in FL
MARIANNA, FL—2026-07-16
BRANNON BROTHERS CONSTRUCTION, LLC
LAKELAND, FL—2026-07-16
SOUTHERN MILLING & LUMBER, INC.
OAKLAND PARK, FL—2026-07-16
PKB CABINETRY
LAKELAND, FL—2026-07-16
ELIJAH WHOLESALE, LLC.
TAMPA, FL—2026-07-16
VALENCIA WHOLESALE, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338805831.