Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: BRANDON INDUSTRIES OF LOUISIANA

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BRANDON INDUSTRIES OF LOUISIANA in 6500 BUNCOMBE RD, SHREVEPORT, LA 71129 (NAICS 335931). OSHA activity number 338811631.

Watch Brandon Industries OF Louisiana — free Get an email when a new federal OSHA severe-injury report for Brandon Industries OF Louisiana is published. One employer, no account, unsubscribe in one click.
Site address
6500 BUNCOMBE RD
City
SHREVEPORT
State
LA
ZIP
71129
Mailing
6500 BUNCOMBE RD, SHREVEPORT, LA 71129
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
335931
Employees
17
Ownership type
A

7 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 11 instances 15 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1680.00 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed and documented for the control of potentially hazardous energy when employees were engaged in activities covered by this section.  The procedures shall clearly and specifically outline the means to enforce compliance including, but not limited to, the following:      The employer did not develop written procedures with specific steps for the control of potentially hazardous energy regarding machines and equipment such as, but not limited to:     a) PCP Assembly Area:         1. Two Ultrasonic Welders        2. Two Auto Bagging Machines     b) Carrier Assembly Area:         1. Two Auto Wire Machines         2. Two Hot Stamp Machines        3. Three Terminal Insertion Machines         4. Heat Staking machine    c) Tool Room Area:        1. Two Brown & Sharpe grinders        2. U.S. Baird Multi Slide        3. Seven Punch Presses        4. Rivet Machine        5. Spot Welder
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.179 G01 V

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1020.00 · Current $612.00 Reduced
29 CFR 1910.179(g)(1)(v): Pendant control boxes shall be constructed to prevent electrical shock and shall be clearly marked for identification of functions.      a) Tool Room; the employer allowed employees to operate an overhead crane to move parts and tools, that did not have pendant buttons marked to identify its functionality.
Recent events (2)
  • — I (S) $612
  • — Z (S) $1020

1910.179 J03

Serious Gravity 1 3 instances 4 exposed
Issued
Abate by
Penalty
Initial $1020.00 · Current $612.00 Reduced
29 CFR 1910.179(j)(3): Periodic inspection. Complete inspections of the crane shall be performed at intervals as generally defined in paragraph (j)(1)(ii)(b) of this section, depending upon its activity, severity of service, and environment, or as specifically indicated below. These inspections shall include the requirements of paragraph (j)(2) of this section and in addition, the following items. Any deficiencies such as listed shall be carefully examined and determination made as to whether they constitute a safety hazard:      The employer failed to ensure that three overhead gantry cranes in the tool room area were periodically inspected.
Recent events (2)
  • — I (S) $612
  • — Z (S) $1020

1910.212 A03 II

Serious Gravity 1 3 instances 2 exposed
Issued
Abate by
Penalty
Initial $1020.00 · Current $612.00 Reduced
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle.      a) Tool Room Area; the following pieces of equipment did not have a guard around the bit to prevent a point of operation injury:        1. Supermax Milling Machine        2. Bridgeport Milling Machine        3. Wilton Strands Drill Press
Recent events (2)
  • — I (S) $612
  • — Z (S) $1020

1910.215 A02

Serious Gravity 1 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $1020.00 · Current $612.00 Reduced
29 CFR 1910.215(a)(2): Guard design. The safety guard shall cover the spindle end, nut, and flange projections.       a) Tool Room Area; the employer allowed employees to operate two Brown & Sharpe grinders, for surface grinding, without a guard covering the spindle end, nut, and flange projections of the grinder.
Recent events (2)
  • — I (S) $612
  • — Z (S) $1020

1910.242 B

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1200.00 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning. Compressed air shall not be used for cleaning purposes except where reduced to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment.      a) Carrier Area; an air nozzle is routinely used for cleaning equipment at compressed air pressures up to 80 psig.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1910.305 G01 IV A

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1020.00 · Current $612.00 Reduced
29 CFR 1910.305(g)(1)(iv)(A): As a substitute for the fixed wiring of a structure;      a) Carrier Area - Square Wire Machine Work Station; an extension cord was used as permanent wiring to power a station work light.
Recent events (2)
  • — I (S) $612
  • — Z (S) $1020

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338811631.