CATOOSA, OK —
OSHA Inspection: TANK CLEANING INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of TANK CLEANING INC. in 5450 E CHANNEL ROAD, CATOOSA, OK 74015 (NAICS 562998). OSHA activity number 338836034.
Where did this inspection happen?
- Establishment
- TANK CLEANING INC.
- Site address
- 5450 E CHANNEL ROAD
- City
- CATOOSA
- State
- OK
- ZIP
- 74015
- Mailing
- 106 E PINE STREET, CEDAR BLUFFS, NE 68015
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 562998
- Employees
- 4
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.146 D04 I
- Issued
- Abate by
- Penalty
- Initial $1700.00 · Current $1700.00
General-duty citation text
29 CFR 1910.146(d)(4)(i): Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not ensure that testing and monitoring equipment needed to comply with 29 CFR 1910.146(d)(5) was maintained properly: a. On or about 2/12/13, Tank 24, An air testing instrument was not properly maintained in that it was not properly zeroed and calibrated and was used for air monitoring of Tank 24 on 2/7/13, 2/8/13, and 2/12/13 for employee entries to remove vegetable oil which exposes employees to oxygen deficiency hazards, burn hazards, and slip and trip hazards.
Recent events (1)
- — Z (S) $1700
1910.146 D05 I
- Issued
- Abate by
- Penalty
- Initial $1700.00 · Current $1700.00
General-duty citation text
29 CFR 1910.146(d)(5)(i): Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), where the employer had established that isolation of the space was infeasible because the space was large or was part of a continuous system, continuous monitoring was not performed. a. On or about 2/7/13, Tank 24, During employee entry operations, continuous air monitoring was not conducted for Tank 24 which had steam piping that was not isolated from Tank 24. An employee worked inside Tank 24 to remove vegetable oil and was exposed to oxygen deficiency hazards, burn hazards, and slip and trip hazards.
Recent events (1)
- — Z (S) $1700
1910.146 E06
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.146(e)(6): The employer did not note any problems encountered during an entry operation on the pertinent permit so that appropriate revisions to the permit space program could be made: a. On or about 2/7/13, Tank 24, The 2/7/13 permit for Tank 24 was not noted for a report of breathing problems on 2/7/13 while working inside Tank 24 to remove recovered vegetable oil and an employee was exposed to oxygen deficiency hazards, burn hazards, and slip and trip hazards.
Recent events (1)
- — Z (S) $0
1910.146 F07
- Issued
- Abate by
- Penalty
- Initial $1700.00 · Current $1700.00
General-duty citation text
29 CFR 1910.146(f)(7): The entry permit that documented compliance and authorized entry to a permit space did not identify the hazards of the permit space to be entered: a. On or about 2/12/13, Tank 24, The 2/7/13, 2/8/13, and 2/12/13 permits for entry of Tank 24 did not identify the hazards of the entering Tank 24 to remove recovered vegetable oil which exposes employees to oxygen deficiency hazards, burn hazards, and slip and trip hazards.
Recent events (1)
- — Z (S) $1700
1910.146 F08
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.146(f)(8): The entry permit that documented compliance and authorized entry to a permit space did not identify the measures used to isolate the permit space and to eliminate or control permit space hazards before entry: a. On or about 2/12/13, Tank 24, The 2/7/13, 2/8/13, and 2/12/13 permits for entry of Tank 24 did not identify the measures used to control steam hazards before entering Tank 24 to remove recovered vegetable oil which exposes employees to oxygen deficiency hazards, burn hazards, and slip and trip hazards.
Recent events (1)
- — Z (S) $0
1910.146 F10
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.146(f)(10): The entry permit that documented compliance and authorized entry to a permit space did not identify the results of initial and periodic tests performed under 29 CFR 1910.146(d)(5), accompanied by the names or initials of the tester: a. On or about 2/12/13, Tank 24, The 2/7/13, 2/8/13, and 2/12/13 permits for entry of Tank 24 did not identify the results of hydrogen sulfide tests performed and did not identify the names or initials of the testers. Employees entered Tank 24 to remove recovered vegetable oil which exposes employees to oxygen deficiency hazards, burn hazards, and slip and trip hazards.
Recent events (1)
- — Z (S) $0
1910.146 F13
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.146(f)(13): The entry permit that documented compliance and authorized entry to a permit space did not identify equipment, such as personal protective equipment, testing equipment, communications equipment, alarm systems, and rescue equipment: a. On or about 2/12/13, Tank 24, The 2/7/13, 2/8/13, and 2/12/13 permits for entry of Tank 24 did not identify the employers planned rescue equipment for employee rescue from Tank 24. Employees entered Tank 24 to remove recovered vegetable oil which exposes employees to oxygen deficiency hazards, burn hazards, and slip and trip hazards.
Recent events (1)
- — Z (S) $0
1910.146 G03
- Issued
- Abate by
- Penalty
- Initial $1700.00 · Current $1700.00
General-duty citation text
29 CFR 1910.146(g)(3): The employer did not provide training that established employee proficiency in the duties required by 29 CFR 1910.146, Permit-required confined spaces, and did not introduce new or revised procedures, as necessary, for compliance: a. On or about 2/12/13, Tank 24, The employer did not provide training that established employee proficiency in correct completion of the employers permit form and did not provide training that established employee proficiency in calibration of a 4 gas meter used for employee entry of Tank 24 on 2/7/13, 2/8/13, and 2/12/13 to remove vegetable oil which exposes employees oxygen deficiency hazards, burns hazards, and slip and trip hazards.
Recent events (1)
- — Z (S) $1700
1910.146 G04
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.146(g)(4): The employer did not certify that the training required by 29 CFR 1910.146(g)(1) through 29 CFR 1910.146(g)(3) had been accomplished: a. On or about 2/12/13, Tank 24, The employer did certify completion of permit required confined space training for employees who entered Tank 24 to remove vegetable oil which exposes employees oxygen deficiency hazards, burns hazards, and slip and trip hazards.
Recent events (1)
- — Z (S) $0
1910.134 M04
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(m)(4): Written materials required to be retained under 29 CFR 1910.134 were not made available upon request to affected employees and to the Assistant Secretary or designee for examination and copying: On or about 2/12/13, Tank 24, The written medical recommendation for employee respirator use and an employee respirator fit test record were not provided to a designee of the Assistant Secretary for an employee expected to use a self-contained breathing apparatus (SCBA) for emergency rescue where employees entered Tank 24 to remove vegetable oil which exposes employees oxygen deficiency hazards, burns hazards, and slip and trip hazards.
Recent events (1)
- — Z (O) $0
More inspections in this industry (NAICS 562998)
ANCHORAGE, AK—2026-07-08
ONE STOP SERVICES
PUYALLUP, WA—2026-06-26
WA317991843 - OLSON BROTHERS PRO VAC LLC
PULASKI, VA—2026-06-19
NEW RIVER RECYCLING, INC.
PRUDHOE BAY, AK—2026-06-01
PACIFIC ENVIRONMENTAL CORPORATION
PRUDHOE BAY, AK—2026-06-01
PACIFIC ENVIRONMENTAL CORPORATION
More inspections in OK
MADILL, OK—2026-07-08
MID AMERICAN STEEL & WIRE CO., LLC
SEILING, OK—2026-06-26
GORE ENERGY
ADA, OK—2026-06-25
PAN AMERICA ELECTRIC , INC.
ADA, OK—2026-06-25
CITATION OIL & GAS CORPORATION
EDMOND, OK—2026-06-23
BRICK EXPERTS INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338836034.