TAMUNING, GU —
OSHA Inspection: LEO PALACE GUAM CORPORATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of LEO PALACE GUAM CORPORATION in 105 GUN BEACH ROAD, TAMUNING, GU 96913 (NAICS 721110). OSHA activity number 338847031.
Where did this inspection happen?
- Establishment
- LEO PALACE GUAM CORPORATION
- Site address
- 105 GUN BEACH ROAD
- City
- TAMUNING
- State
- GU
- ZIP
- 96913
- Mailing
- 105 GUN BEACH ROAD STEVE PALOMERO CHIEF ENGINEER, TAMUNING, GU 96913
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 721110
- Employees
- 400
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.37 B02
- Issued
- Abate by
- Penalty
- Initial $3000.00 · Current $1500.00 Reduced
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit": Prego Kitchen: On February 12, 2013, and at times prior thereto, EXIT signage had not marked the designated double exit doors.
Recent events (2)
- — I (O) $1500
- — Z (S) $3000
1910.219 D01
- Issued
- Abate by
- Penalty
- Initial $4000.00 · Current $3000.00 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): On February 12, 2013, and at times prior thereto, belt and pulley assemblies driving exhaust fan motors were not fully enclosed in the following locations; A. Plant Room B. Engineering Shop
Recent events (2)
- — I (S) $3000
- — Z (S) $4000
1910.219 E01 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven -7 feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt: On February 12, 2013, and at times prior thereto, belt and pulley assemblies driving exhaust fan motors were not fully enclosed in the following locations; A. Plant Room B. Engineering Shop
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.253 B04 I
- Issued
- Abate by
- Penalty
- Initial $4000.00 · Current $3000.00 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(i): Oxygen cylinders were stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near other substance likely to cause or accelerate fire: Engineering Shop: On February 12, 2013, and at times prior thereto, oxygen and acetylene compressed gas H-cylinders were stored together.
Recent events (2)
- — I (S) $3000
- — Z (S) $4000
1910.305 B01 II
- Issued
- Abate by
- Penalty
- Initial $4000.00 · Current $3000.00 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: On February 12, 2013, and at times prior thereto, electrical equipment was not properly guarded and live wiring was exposed in the following locations; A. Plant Room: Electrical Panel LP-ER had five breaker openings. B. Prego Kitchen: Electrical Panel LP-SFR had one breaker opening.
Recent events (2)
- — I (S) $3000
- — Z (S) $4000
1910.37 B05
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g. closet): Plant Room: On February 12, 2013, and at times prior thereto, two doors which could be mistaken for exits were not properly marked with their designation.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 721110)
SAN RAFAEL, CA—2026-07-17 00:00:00
EQUINOX UGI SR INVESTMENTS, LLC
PALM SPRINGS, CA—2026-07-16 00:00:00
LA SERENA VILLAS
BOISE, ID—2026-07-16 00:00:00
RAYMOND MANAGEMENT COMPANY
ORLANDO, FL—2026-07-16 00:00:00
EVERMORE ORLANDO RESORT
LAS VEGAS, NV—2026-07-15 00:00:00
THE MARCUS CORPORATION ETAL
More inspections in GU
BARRIGADA, GU—2026-01-22 00:00:00
DURI CORPORATION
TAMUNING, GU—2026-01-21 00:00:00
DLR CORPORATION
BARRIGADA, GU—2026-01-21 00:00:00
DURI CORPORATION
TAMUNING, GU—2026-01-20 00:00:00
MG CONSTRUCTION COMPANY
BARRIGADA, GU—2026-01-20 00:00:00
PFM -VERTEX-LMS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338847031.