TAMUNING, GU ·
OSHA Inspection: LEO PALACE GUAM CORPORATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of LEO PALACE GUAM CORPORATION in 105 GUN BEACH ROAD, TAMUNING, GU 96913 (NAICS 721110). OSHA activity number 338847031.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LEO PALACE GUAM CORPORATION
- Site address
- 105 GUN BEACH ROAD
- City
- TAMUNING
- State
- GU
- ZIP
- 96913
- Mailing
- 105 GUN BEACH ROAD STEVE PALOMERO CHIEF ENGINEER, TAMUNING, GU 96913
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 721110
- Employees
- 400
- Ownership type
- Private (A)
Citations
6 citations on file for this inspection.
1910.37 B02
- Issued
- Mar 25, 2013
- Abate by
- Mar 29, 2013
- Penalty
- Initial $3,000 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit": Prego Kitchen: On February 12, 2013, and at times prior thereto, EXIT signage had not marked the designated double exit doors.
Recent events (2)
- · I (O) $1500
- · Z (S) $3000
1910.219 D01
- Issued
- Mar 25, 2013
- Abate by
- Apr 4, 2013
- Penalty
- Initial $4,000 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): On February 12, 2013, and at times prior thereto, belt and pulley assemblies driving exhaust fan motors were not fully enclosed in the following locations; A. Plant Room B. Engineering Shop
Recent events (2)
- · I (S) $3000
- · Z (S) $4000
1910.219 E01 I
- Issued
- Mar 25, 2013
- Abate by
- Apr 4, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven -7 feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt: On February 12, 2013, and at times prior thereto, belt and pulley assemblies driving exhaust fan motors were not fully enclosed in the following locations; A. Plant Room B. Engineering Shop
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.253 B04 I
- Issued
- Mar 25, 2013
- Abate by
- Apr 4, 2013
- Penalty
- Initial $4,000 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(i): Oxygen cylinders were stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near other substance likely to cause or accelerate fire: Engineering Shop: On February 12, 2013, and at times prior thereto, oxygen and acetylene compressed gas H-cylinders were stored together.
Recent events (2)
- · I (S) $3000
- · Z (S) $4000
1910.305 B01 II
- Issued
- Mar 25, 2013
- Abate by
- Mar 29, 2013
- Penalty
- Initial $4,000 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: On February 12, 2013, and at times prior thereto, electrical equipment was not properly guarded and live wiring was exposed in the following locations; A. Plant Room: Electrical Panel LP-ER had five breaker openings. B. Prego Kitchen: Electrical Panel LP-SFR had one breaker opening.
Recent events (2)
- · I (S) $3000
- · Z (S) $4000
1910.37 B05
- Issued
- Mar 25, 2013
- Abate by
- Mar 29, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g. closet): Plant Room: On February 12, 2013, and at times prior thereto, two doors which could be mistaken for exits were not properly marked with their designation.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 721110)
More inspections in GU
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 338847031.