SIX MILE RUN, PA ·
OSHA Inspection: LAWRUK BUILDERS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of LAWRUK BUILDERS, INC. in 1100 SIX MILE RUN ROAD, SIX MILE RUN, PA 16679 (NAICS 236220). OSHA activity number 338852239.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LAWRUK BUILDERS, INC.
- Site address
- 1100 SIX MILE RUN ROAD
- City
- SIX MILE RUN
- State
- PA
- ZIP
- 16679
- Mailing
- 210 W. PLANK ROAD, ALTOONA, PA 16602
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 9
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
1926.152 E04
- Issued
- Mar 19, 2013
- Abate by
- Mar 29, 2013
- Penalty
- Initial $1,200 · Current $864 Reduced
General-duty citation text
29 CFR 1926.152(e)(4): Units dispensing flammable or combustible liquids were not protected against collision damage: a) Jobsite, Six Mile Run Area VFD, 1100 Six Mile Run Road, Six Mile Run, PA: On or before 02/12/13, a manual dispensing unit on 275 gallon diesel tank located adjacent to the job trailer was not protected against collision damage. The dispensing unit and tank were used to refuel a Gehl RT forklift, RS 8-42. b) Jobsite, Six Mile Run Area VFD, 1100 Six Mile Run Road, Six Mile Run, PA: On or before 02/12/13, a manual dispensing unit on a 36 inch diameter by 5 feet long kerosene tank was not protected against collision damage. The tank was located adjacent to rear of the building under construction and a truck crane with a personnel platform used by a sub-contractor was operating in the immediate area.
Recent events (2)
- · I (O) $864
- · Z (S) $1200
1926.451 C02 IV
- Issued
- Mar 19, 2013
- Penalty
- Initial $1,200 · Current $864 Reduced
General-duty citation text
29 CFR 1926.451(c)(2)(iv): Front-end loaders and similar pieces of equipment were used to support scaffold platforms when they were not specifically designed by the manufacturer for such use: a) Jobsite, Six Mile Run Area VFD, 1100 Six Mile Run Road, Six Mile Run, PA: On or before 02/12/13, two (2) employees working inside a personnel platform fabricated by the employer installing siding material which was elevated approximately 4 feet from the ground level by a rented Gehl RT forklift, RS 8-42. The personnel platform was not approved for use by the forklift truck manufacturer and was not firmly secured to the lifting carriage and/or forks
Recent events (2)
- · I (S) $864
- · Z (S) $1200
1926.602 D
- Issued
- Mar 19, 2013
- Abate by
- Mar 29, 2013
- Penalty
- Initial $2,000 · Current $1,440 Reduced
General-duty citation text
29 CFR 1926.602(d): The employer did not certify that each operator had been trained and evaluated as required by paragraph 29 CFR 1910.178(l): a) Jobsite, Six Mile Run Area VFD, 1100 Six Mile Run Road, Six Mile Run, PA: On or before 02/12/13, the employer did not certify that the operator of the Gehl Rough Terrain forklift, RS 8-42 was trained and evaluated in the operation of the powered industrial truck.
Recent events (2)
- · I (O) $1440
- · Z (S) $2000
1926.150 C01 VIII
- Issued
- Mar 19, 2013
- Abate by
- Mar 29, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.150(c)(1)(viii): Portable fire extinguishers were not inspected periodically in accordance with maintenance and use of portable fire extinguishers, N.F.P.A. No. 10A-1970: a) Jobsite, Six Mile Run Area VFD, 1100 Six Mile Run Road, Six Mile Run, PA: On or before 02/12/13, an Amerex portable fire extinguisher, Model 500, 2A, 10BC, located by the job trailer was last inspected by NAFED in March 2001.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 236220)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 338852239.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.