ORRINGTON, ME —
OSHA Inspection: ESOCO ORRINGTON, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ESOCO ORRINGTON, LLC in 29 INDUSTRIAL WAY, ORRINGTON, ME 04474 (NAICS 562213). OSHA activity number 338854839.
Where did this inspection happen?
- Establishment
- ESOCO ORRINGTON, LLC
- Site address
- 29 INDUSTRIAL WAY
- City
- ORRINGTON
- State
- ME
- ZIP
- 04474
- Mailing
- P. O. BOX 160, ORRINGTON, ME 04474
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 562213
- Employees
- 75
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.212 A05
- Issued
- Mar 6, 2013
- Abate by
- Mar 14, 2013
- Penalty
- Initial $4,900 · Current $4,900
General-duty citation text
29 CFR 1910.212(a)(5): Exposure of blades. When the periphery of the blades of a fan is less than seven (7) feet above the floor or working level, the blades shall be guarded. The guard shall have openings no larger than one-half (1/2) inch. Fire Fighting Equipment Locker - The guard to the Taskmaster heater fan had 2" openings.
Recent events (2)
- — I (S) $4900
- — Z (S) $4900
1910.304 G05
- Issued
- Mar 6, 2013
- Abate by
- Mar 13, 2013
- Penalty
- Initial $4,900 · Current $4,900
General-duty citation text
29 CFR 1910.304(g)(5): Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent, continuous, and effective. In the following instances, the path to ground from equipment were not permanent, continuous, and effective: I & E Tech Room - The Sharp microwave oven had an open ground. I & E Tech Room - The two work bench power pack strips and yellow extension cord had open grounds.
Recent events (2)
- — I (S) $4900
- — Z (S) $4900
1910.305 G01 IV A
- Issued
- Mar 6, 2013
- Abate by
- Mar 14, 2013
- Penalty
- Initial $1,785 · Current $1,785
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables shall not be used as a substitute for the fixed wiring of a structure: I & E Tech Room - The yellow extension cord was used to permanently energize the power pack strips at on the work benches.
Recent events (2)
- — I (S) $1785
- — Z (S) $1785
1910.157 C01
- Issued
- Mar 6, 2013
- Abate by
- Mar 12, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(c)(1): The employer shall provide portable fire extinguishers and shall mount, locate and identify them so that they are readily accessible to employees without subjecting the employees to possible injury. Rolling Stock Maintenance Shop - A 10 pound dry chemical fire extinguisher was not mounted at its location.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 B01 II
- Issued
- Mar 6, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings shall be effectively closed. Maintenance Department - The overhead hoist disconnect was missing a knockout plug.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.151 C
- Issued
- Mar 6, 2013
- Abate by
- Apr 8, 2013
- Penalty
- Initial $2,380 · Current $0 Reduced
General-duty citation text
29 CFR 1910.151(c): Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body shall be provided within the work area for immediate emergency use. In the following instances; suitable facilities for quick drenching or flushing of the eyes and body were not immediately available due to hazard creating incumbrances. a) Cooling Tower - A 6" high dike surrounding the 500 gallon tank of sodium hypochlorite 12.5% area was an incumbrance to the emergency shower and eyewash. b) Water Treatment - The path from the RO system and caustic soda tank had ground incumbrances with handles sticking up from the floor cover plates.
Recent events (2)
- — I (O) $0
- — Z (S) $2380
1910.178 Q07
- Issued
- Mar 6, 2013
- Abate by
- Mar 14, 2013
- Penalty
- Initial $2,975 · Current $0 Reduced
General-duty citation text
29 CFR 1910.178(q)(7): Industrial trucks shall be examined before being placed in service, and shall not be placed in service if the examination shows any condition adversely affecting the safety of the vehicle. Such examination shall be made at least daily. Where industrial trucks are used on a round-the-clock basis, they shall be examined after each shift. Defects when found shall be immediately reported and corrected. In the Yard - The rear floodlight on the Toyota 7785 forklift did not work.
Recent events (2)
- — I (O) $0
- — Z (S) $2975
1910.303 B01 VI
- Issued
- Mar 6, 2013
- Penalty
- Initial $4,900 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(b)(1)(vi): Electrical equipment shall be free from recognized hazards that are likely to cause death or serious physical harm to employees. Arcing effects shal be taken into consideration in determining the safety of the equipment. Maintenance Department - The plug attached to the Milwaukee 14" abrasive cut-off saw, serial #98242814, had been damaged by the arcing effects between the receptacle and ungrounded prong.
Recent events (2)
- — I (O) $0
- — Z (S) $4900
More inspections at Esoco Orrington, LLC
View Esoco Orrington, LLC's full OSHA safety record →
More inspections in this industry (NAICS 562213)
More inspections in ME
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338854839.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.