GUILFORD, CT ·
OSHA Inspection: DENICOLA PLUMBING, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DENICOLA PLUMBING, LLC in 151 BLUFF VIEW DRIVE, GUILFORD, CT 06437 (NAICS 238220). OSHA activity number 338888837.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DENICOLA PLUMBING, LLC
- Site address
- 151 BLUFF VIEW DRIVE
- City
- GUILFORD
- State
- CT
- ZIP
- 06437
- Mailing
- P.O. BOX 263, DURHAM, CT 06422
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238220
- Employees
- 2
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
1926.102 A01
- Issued
- May 1, 2013
- Penalty
- Initial $1,600 · Current $1,120 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: JOBSITE: The employee operating the Ryobi power saw to cut wood was not wearing eye protection.
Recent events (2)
- · I (S) $1120
- · Z (S) $1600
1926.405 B02
- Issued
- May 1, 2013
- Abate by
- May 13, 2013
- Penalty
- Initial $2,000 · Current $1,400 Reduced
General-duty citation text
29 CFR 1926.405(b)(2): In energized installations, each outlet box did not have a cover, faceplate, or fixture canopy: JOBSITE: The duplex electrical outlet box, in which two (2) extension cords were plugged to power portable electric tools was missing a faceplate.
Recent events (2)
- · I (S) $1400
- · Z (S) $2000
1926.403 E
- Issued
- May 1, 2013
- Abate by
- May 13, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.403(e): All splices and joints and free ends of conductors were not covered with insulation equivalent to that of the conductors or with an insulating device designed for the purpose: JOBSITE: The power cord of the Ryobi saw was repaired by splicing with electric tape that did not retain the insulation, outer sheathing properties and/or usage characterstics of the cord.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.404 F06
- Issued
- May 1, 2013
- Abate by
- May 13, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: JOBSITE: The attachment plugs of an orange/black flexible cord and an orange/black three way flexible cord, both used to power a Ryobi saw were missing grounding pins.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at Denicola Plumbing, LLC
View Denicola Plumbing, LLC's full OSHA safety record →
More inspections in this industry (NAICS 238220)
More inspections in CT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 338888837.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.