DUTCH HARBOR, AK ·
OSHA Inspection: ICICLE SEAFOODS INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ICICLE SEAFOODS INC in M/V GORDON JENSEN 1829 BALLYHOO ROAD, DUTCH HARBOR, AK 99692 (NAICS 311712). OSHA activity number 338900434.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ICICLE SEAFOODS INC
- Site address
- M/V GORDON JENSEN 1829 BALLYHOO ROAD
- City
- DUTCH HARBOR
- State
- AK
- ZIP
- 99692
- Mailing
- P.O. BOX 79003 4019 21ST AVE W, SEATTLE, WA 98199
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311712
- Employees
- 185
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
1910.119 D03 I E
- Issued
- Mar 22, 2013
- Abate by
- Apr 19, 2013
- Penalty
- Initial $5,000 · Current $2,500 Reduced
0170
General-duty citation text
29 CFR 1910.119(d)(3)(i)(E): The employer did not compile information pertaining to the equipment in the process including the documented system design: Refrigeration space: On or about February 11, 2013 and at times prior thereto, the employer had not documented the design of the emrgency ventilation system. This condition exposed employees to inhalation and eye and skin burn hazards in the event of an uncontrolled release of anhydrous ammonia.
Recent events (2)
- · I (S) $2500
- · Z (S) $5000
1910.119 D03 I B
- Issued
- Mar 22, 2013
- Abate by
- Apr 19, 2013
- Penalty
- Initial $0 · Current $0
0170
General-duty citation text
29 CFR 1910.119(d)(3)(i)(B): Process safety information did not include a block flow diagram or simplified process flow diagram: Refrigeration space: On or about February 11, 2013 and at times prior thereto, the employer had not developed complete piping and instrument diagrams for the process. This condition exposed employees to inhalation and eye and skin burn hazards in the event of an uncontrolled release of anhydrous ammonia.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.119 D02 I A
- Issued
- Mar 22, 2013
- Abate by
- Apr 19, 2013
- Penalty
- Initial $0 · Current $0
0170
General-duty citation text
29 CFR 1910.119(d)(2)(i)(A): Process safety information did not include a block flow diagram or simplified process flow diagram: Refrigeration space: On or about February 11, 2013 and at times prior thereto, the employer had not developed a block flow diagram or equivalent. This condition exposed employees to inhalation and eye and skin burn hazards in the event of an uncontrolled release of anhydrous ammonia.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.119 F01 I B
- Issued
- Mar 22, 2013
- Abate by
- Apr 19, 2013
- Penalty
- Initial $0 · Current $0
0170
General-duty citation text
29 CFR 1910.119(f)(1)(i)(B)): The employer did not develop and implement written operating procedures for normal operations: Refrigeration space: On or about February 11, 2013 and at times prior thereto, the employer had not updated the compressor oil change interval procedure. This condition exposed employees to inhalation and eye and skin burn hazards in the event of an uncontrolled release of anhydrous ammonia.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.119 D03 II
- Issued
- Mar 22, 2013
- Abate by
- Apr 19, 2013
- Penalty
- Initial $25,000 · Current $12,500 Reduced
0170
General-duty citation text
29 CFR 1910.119(d)(3)(ii): The employer did not document that equipment complies with recognized and generally accepted good engineering practices: M/V Gordon Jensen Refrgieration System: On or about February 11, 2013 and at times prior thereto, valve identification tags were missing at multiple locations of the refrigeration system. This included but was not limited to: 1. Oil drains, Sabroe compressors; 2. Heat Exchanger; 3. Cornell Liquid Pumps relief vent lines; 4. LPR Oil Pots -40 & -15, drain valves; 5. Sabroe Oil Filter housing; 6. Sabroe compressor transducers; 7. Mycom oil filter; 8. Mycom oil drain; 9. Vilter compressor oil filter transducers; 10. Port-side external Blast Freezer; 11. Starboard-side plate freezer zone 212; 12. Control Pressure Receiver drain valve and bullet glass level isolator; and, 13. North Star ice machine vapor suction and liquid supply. Valve identification was not being maintained as required by the Process Safety Management (PSM) program which incorporated by reference ASHRAE 15 and ASHRAE 26. This condition exposed employees to inhalation and eye and skin burn hazards in the event of an uncontrolled release of anhydrous ammonia. Icicle Seafoods, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard which was contained in OSHA inspection number 307506535, citation number 2, item number 1 and was affirmed as a final order on September 22, 2010, with respect to a workplace located at P/V Arctic Star, Clark's Point, Alaska.
Recent events (2)
- · I (R) $12500
- · Z (R) $25000
More inspections at Icicle Seafoods INC
View Icicle Seafoods INC's full OSHA safety record →
More inspections in this industry (NAICS 311712)
More inspections in AK
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 338900434.