Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: BRIDGEPOINTE GROUP

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of BRIDGEPOINTE GROUP in 381 KNOLLWOOD RD, ELMSFORD, NY 10523 (NAICS 236220). OSHA activity number 338906993.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bridgepointe Group for free Get an email when a new federal OSHA severe-injury report for Bridgepointe Group is published. One employer, no account, unsubscribe in one click.
Establishment
BRIDGEPOINTE GROUP
Site address
381 KNOLLWOOD RD
City
ELMSFORD
State
NY
ZIP
10523
Mailing
47A N LAWN AVE, ELMSFORD, NY 10523
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
4
Ownership type
Private (A)

2 citations on file for this inspection.

1926.416 A01

Serious Gravity 10 1 instance 5 exposed
Issued
Mar 11, 2013
Penalty
Initial $2,800 · Current $2,100 Reduced
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means:    Location: 381 Knollwood Rd White Plains NY     On or about 2/13/13,  a) Employees installed roof trusses and roof decking in close proximity to incoming electric service lines. The service lines were not de-energized and grounded or effectively guarded.
Recent events (2)
  • · I (S) $2100
  • · Z (S) $2800

1926.502 D15

Serious Gravity 5 2 instances 2 exposed
Issued
Mar 11, 2013
Penalty
Initial $2,000 · Current $1,500 Reduced
29 CFR 1926.502(d)(15): Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached nor was it designed, installed and used as part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person:    Location: 381 Knollwood Rd White Plains NY     On or about 2/13/13,  a) Employees anchored their lifelines to roof trusses before they were structurally sound to meet the requirements of this section.
Recent events (2)
  • · I (S) $1500
  • · Z (S) $2000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 338906993.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.