OSHA Inspection: UTEX INDUSTRIES, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of UTEX INDUSTRIES, INC. in 605 UTEX DRIVE, WEIMAR, TX 78962 (NAICS 339991). OSHA activity number 338908569.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Utex Industries, INC. — free Get an email when a new federal OSHA severe-injury report for Utex Industries, INC. is published. One employer, no account, unsubscribe in one click.
Site address
605 UTEX DRIVE
City
WEIMAR
State
TX
ZIP
78962
Mailing
605 UTEX DRIVE, WEIMAR, TX 78962
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
339991
Employees
287
Ownership type
A

47 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 2 instances 39 exposed
Issued
Aug 9, 2013
Abate by
Aug 12, 2013
Penalty
Initial $4,000 · Current $4,000
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the recognized hazard of being struck by fragments of plastic pipe due to the pipe's potential for explosive shattering when used to transport compressed air.    On or about February 12, 2013, the compressed air system was installed in manufacturing area(s) using polyvinyl chloride (PVC) pipe.  a. in the mold storage area used to supply air to the paint booth area   b. in the oven cure area for supplied air respirators.  PVC pipe and fittings do not possess shatter resistant properties and the brittle PVC material can be broken or shattered by external forces and stress.  This pipe is designed for transmittal of liquids which do not possess the high amounts of stored energy present in compressed gases. This hazard has been recognized by the manufacturer of this PVC product, the Plastic Pipe Institute, the American National Standards Institute, and OSHA through an official Hazard Information Bulletin.    Among other methods, suitable abatement actions include the complete enclosure, burial, or otherwise guarding of the installation according to specifications approved by a professional consulting engineer, or the installation of the compressed air system using products which have been suitably evaluated and are recommended by the manufacturer for the particular intended service.
Recent events (2)
  • — I (S) $4000
  • — Z (S) $4000

5(a)(1)

Serious Gravity 5 1 instance 20 exposed
Issued
Aug 9, 2013
Abate by
Oct 30, 2013
Penalty
Initial $4,000 · Current $4,000
OSH ACT of 1970 Section (5)(a)(1):  The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazards of being struck by collapsing storage racks.      On or about February 13, 2013, in the rubber mill area, the employer failed to replace damaged racks. The legs of the racks were bent and deformed.    One feasible and acceptable abatement method to correct this hazard includes but is not limited to:  develop and implement a program to periodically inspect the storage racks and ensure damage is promptly repaired in accordance with ANSI MH16.1:2008, Section 1.4.9 Rack Damage.
Recent events (2)
  • — I (S) $4000
  • — Z (S) $4000

1910.22 A01

Serious Gravity 5 3 instances 287 exposed
Issued
Aug 9, 2013
Abate by
Aug 12, 2013
Penalty
Initial $5,000 · Current $5,000
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition:    Carbon black and grime covered the safety warning signs provided in the following areas, creating a fire hazard to employees.  a.  On or about April 10, 2013 the warning signs on cure ovens located in the cure oven room could not be read. b.  On or about February 12, 2013 the warning signs on the bolling rubber mixer were obscured by carbon black and dust, located in the Rubber Department, Mixing Mezzanine. c.   On or about February 13, 2013 the booth used for grinding rubber coating on aluminum impellers: explosive rubber dust from grinding operation is allowed in excessive accumulations that are cleaned only once a week.
Recent events (2)
  • — I (S) $5000
  • — Z (S) $5000

1910.22 A02

Serious Gravity 5 18 instances 22 exposed
Issued
Aug 9, 2013
Abate by
Aug 12, 2013
Penalty
Initial $4,000 · Current $1,000 Reduced
29 CFR 1910.22(a)(2): Where wet processes were used, drainage was not maintained, and false floors, platforms, mats, or other dry standing places were not provided when practicable.    On or about February 12, 2013, the area under and around the 480 volt electrical panels was covered with water from the autoclave process.  The panels including, but not limited to high voltage panel 429, were located along the South wall of the extruder room. This condition created an electrical hazard to workers.  Autoclave condensation was pooling on the floor under electrical panel boxes.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $4000

1910.23 A08

Serious Gravity 1 1 instance 16 exposed
Issued
Aug 9, 2013
Abate by
Aug 12, 2013
Penalty
Initial $3,000 · Current $3,000
29 CFR 1910.23(a)(8): Every floor hole into which persons can accidentally walk were not guarded:  On or about February 12, 2013 the drain cover was missing from a floor drain in the center of the boiler room. This left a round 8 inch by 2 inch deep hole in the floor where a scissor lift wheel could fall into upsetting the lift used to access the many overhead lights and pipes. This condition was a fall hazard to workers in the boiler room.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $3000

1910.23 D01

Serious Gravity 1 1 instance 10 exposed
Issued
Aug 9, 2013
Abate by
Aug 12, 2013
Penalty
Initial $3,000 · Current $3,000
29 CFR 1910.23(d)(1): Every flight of stairs having four or more risers was not equipped with standard stair railings or standard handrails as specified in paragraphs (d)(1)(i) through (v) of this section, the width of the stair to be measured clear of all obstructions except handrails:  On or about February 12, 2013 the stairs leading to the entrance of the press department from the parking lot did not have stair rails, exposing employees to a fall hazard when entering the establishment.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $3000

1910.37 B02

Serious Gravity 1 2 instances 42 exposed
Issued
Aug 9, 2013
Abate by
Aug 12, 2013
Penalty
Initial $3,000 · Current $3,000
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":  On or about February13, 2013 the following exits were not marked, creating a fire hazard to employees:   a.  Exit to the parking lot from the shipping department was not marked. b.  Exit to outside in the rubber mill area was not marked.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $3000

1910.37 B05

Serious Gravity 1 1 instance 10 exposed
Issued
Aug 9, 2013
Abate by
Aug 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit must be marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g., closet).  On or about February 12, 2013, the door leading to the chiller room was not identified with a sign "not an exit".  This condition exposed workers to a fire hazard in the chiller room area.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.101 B

Serious Gravity 5 2 instances 16 exposed
Issued
Aug 9, 2013
Abate by
Aug 12, 2013
Penalty
Initial $4,000 · Current $1,000 Reduced
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tank cars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6:    On or about February 12, 2013, the following inhalation, fire and explosion hazards were identified:    a.  Paragraph 3.2.1 Where removable caps are provided for valve protection, such caps should be kept on cylinders at all times except when cylinders are in use.  A nitrogen cylinder was located near an exit doorway and a freon cylinder was located in the boiler room without caps.  b.  Paragraph 3.6.4  Use poison gases in cylinder sizes that will insure complete usage of the cylinder content in a reasonable amount of time. The cylinders were located in the loading dock area and had been there for months.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $4000

1910.106 E02 II

Serious Gravity 5 2 instances 27 exposed
Issued
Aug 9, 2013
Abate by
Aug 12, 2013
Penalty
Initial $4,000 · Current $4,000
29 CFR 1910.106(e)(2)(ii): "Containers." Flammable liquids were not stored in tanks or closed containers.  On or about February 12, 2013, open containers of flammable liquids were found in the following areas, creating a fire hazard:  a. Plastic bottles of MEK and a safety can containing MEK with defective lid, located in injection molding, Plastic Extrusion Department. b. Open containers of MEK and paint, located in the hot room, Rubber Extruding Department.
Recent events (2)
  • — I (S) $4000
  • — Z (S) $4000

1910.107 B05 I

Serious Gravity 5 2 instances 17 exposed
Issued
Aug 9, 2013
Abate by
Aug 12, 2013
Penalty
Initial $5,000 · Current $5,000
29 CFR 1910.107(b)(5)(i): Visible gauges or audible alarms or pressure activated devices were not installed to indicate or insure that the required air velocity is maintained.  On or about February 12, 2013, no gauges or alarms were provided in the following spray booths, exposing employees to a fire hazard.  a.  Dry-filter spray booth used for spray coating rubber parts, located in Metal Prep, Mold Storage [Old Urethane Room]. b.  Dry-filter spray booth Unit E296 used for spray application of flammable coatings, located in the metal prep area.
Recent events (2)
  • — I (S) $5000
  • — Z (S) $5000

1910.107 B05 IV

Serious Gravity 5 2 instances 17 exposed
Issued
Aug 9, 2013
Abate by
Aug 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.107(b)(5)(iv): Space within the spray booth on the downstream and upstream sides of filters were not protected with approved automatic sprinklers:  On or about February 12, 2013 the spray booths did not have an automatic sprinkler system, located in the metal prep area, exposing employees to the hazards of fire.  a.  Dry-filter spray booth used for spray coating rubber parts was not equipped with automatic fire suppression, located in  Metal Prep, Mold Storage [Old Urethane Room]. b.  Dry-filter spray booth Unit E296 used for spray application of flammable coatings was not equipped with automatic fire suppression.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 B05 VI

Serious Gravity 5 2 instances 17 exposed
Issued
Aug 9, 2013
Abate by
Aug 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.107(b)(5)(vi): Clean filters or filter rolls were not noncombustible or of a type having a combustibility not in excess of class 2 filters as listed by Underwriters' Laboratories, Inc. Filters and filter rolls were alternately used for different types of coating materials, where the combination of materials may be conducive to spontaneous ignition. See also paragraph (g)(6) of this section.  On or about February 12, 2013 common household 3M air filters were being used in spray booth applications, exposing employees to the hazards of fire:  a.  Dry filter spray booth used for spray coating rubber parts, located in Metal Prep, Mold Storage [Old Urethane Room]. b.  Dry filter spray booth Unit E296 used for spray application of flammable coatings, located in the metal prep. area.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 B09

Serious Gravity 5 2 instances 17 exposed
Issued
Aug 9, 2013
Abate by
Aug 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.107(b)(9): Spray booths were not so installed that all portions are readily accessible for cleaning. A clear space of not less than 3 feet on all sides was not kept free from storage or combustible construction.  On or about February 12, common combustibles including cardboard boxes, wood tables, fiber barrels, and other items were stored within 3 feet of a spray booth used by employees for spraying parts with flammable coatings, exposing employees to fire hazards.   a.  Dry-filter spray booth used for spray coating rubber parts, located in Metal Prep, Mold Storage [Old Urethane Room].  b.  Dry-filter spray booth Unit E296 used for spray application of flammable coatings located in the Metal Prep department.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 G02

Serious Gravity 5 2 instances 17 exposed
Issued
Aug 9, 2013
Abate by
Aug 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.107(g)(2): All spraying areas were not kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary:  On or about February 12, 2013, in the following areas, residue from spraying operations with flammable adhesives accumulated in spray booths, exposing employees to the hazards of fire.  a.  Dry-filter spray booth used for spray coating rubber parts, located in Metal Prep, Mold Storage [Old Urethane Room]. b.  Dry-filter spray booth Unit E296 used for spray application of flammable coatings, located in the metal prep area.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.157 D02

Serious Gravity 1 3 instances 17 exposed
Issued
Aug 9, 2013
Abate by
Aug 12, 2013
Penalty
Initial $3,000 · Current $3,000
29 CFR 1910.157(d)(2): Portable fire extinguishers for use on Class A fires were not distributed so that the travel distance for employees to any extinguisher was 75 feet or less:  On or about February 12, 2013, workers were exposed to fire hazards involving Class A combustible materials, in that, a class A fire extinguisher was not provided in the following areas:  a.  The mixing mezzanine.   b.  The metal prep, mold storage (old Urethane Room) . c.  On top of the string tower, located in the braiding department.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $3000

1910.157 E03

Serious Gravity 1 1 instance 10 exposed
Issued
Aug 9, 2013
Abate by
Aug 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check:  On or about February 12, 2013 the last inspection date on a FIREMASTER, Model SY 2014, Serial#KP-00078216 was September 2011.  The fire extinguisher was located in the North side Quansa Hut Lean-to where LP, acetylene and other gases were stored.  This condition created a fire hazard for workers.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 A06

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 9, 2013
Abate by
Aug 12, 2013
Penalty
Initial $5,000 · Current $1,000 Reduced
29 CFR 1910.178(a)(6): The employer did not ensure that all nameplates and markings were in place:    On or about February 12, 2013, Crown forklift unit 31 was lacking safety stickers provided on an identical model.  The stickers are the type commonly found on forklifts, which explain the requirements to wear seat belts and remain in the operator's seat during a roll over.  The forklift was in the friction house area and created a crush by equipment hazard to employees.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $5000

1910.178 P01

Serious Gravity 5 4 instances 20 exposed
Issued
Aug 9, 2013
Abate by
Aug 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition:  On or about Feburary 12, 2013, the following defects were found on forklifts located in the production area exposing operators to the hazards of fire and/or being crushed by the forklift in the event of a collision or rollover:       a.  The seat belts on a Crown Forklift #31 forklift had not been replaced.  This forklift was used in the friction tower area. b.  Clark forklift unit number E481 did not have seat belts.  This forklift was found in the shipping department. c.  Yale forklift unit #E899 did not have a fire extinguisher, located in rubber warehouse mold storage area. d.  Clark forklift unit number E474 did not have seat belts, located in the production area.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 Q05

Serious Gravity 1 1 instance 20 exposed
Issued
Aug 9, 2013
Abate by
Aug 12, 2013
Penalty
Initial $3,000 · Current $3,000
29 CFR 1910.178(q)(5): All parts of industrial trucks requiring replacement were not replaced only by parts equivalent as to safety with those used in the original design.  On or about February 12, 2013 the wire rope clip attaching the load line to a spring of the Hallowell Hustler was installed backwards, exposing employees to the hazards of the failure of the lift system.  The lift was located in the shipping department picker area.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $3000

1910.178 Q06

Serious Gravity 1 1 instance 3 exposed
Issued
Aug 9, 2013
Abate by
Aug 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.178(q)(6): Industrial trucks were altered so that the relative positions of the various parts are different from what they were when originally received from the manufacturer, or were altered either by the addition of extra parts not provided by the manufacturer or by the elimination of any parts, except as provided in paragraph (q)(12) of this section. Additional counterweighting of fork trucks was done without being approved by the truck manufacturer.  On or about February 12, 2013, located in the material storage area, a 1' by 3' solid steel cylinder was attached to the back of a Yale forklift, Big Bertha E899, as a counterweight, affecting the stability of the forklift, exposing the operator and others to the hazards of being struck by the forklift.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.184 E01

Serious Gravity 1 6 instances 46 exposed
Issued
Aug 9, 2013
Abate by
Aug 12, 2013
Penalty
Initial $3,000 · Current $1,000 Reduced
29 CFR 1910.184(e)(1): Alloy steel sling(s) did not have permanently affixed durable identification stating size, grade, rated capacity, and reach:    On or about February 12, 2013, workers were using job made chain slings that did not have an identification tag on them exposing employees to the hazards of being struck by falling loads.    a.  Spreader bar with a welded chain on each end was used in the Braiding department to lift parts in and out of hot wax dip tanks.  b.  Two and three legged slings located in the sand blast area.  c.  Chain sling used to hold PVC pipe together located in the boiler room.  d.  Job made sling used to lift calenders in place located in the extruding area.  e.  Two legged slings used to lift mold components located in the press department.  f.   Three part chain sling used to move mold components in the press department for the Cutter Hammer Press.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $3000

1910.184 H01

Serious Gravity 1 1 instance 3 exposed
Issued
Aug 9, 2013
Abate by
Aug 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.184(h)(1): Employers did not use only natural and synthetic fiber-rope slings that have permanently affixed and legible identification markings stating the rated capacity for the type(s) of hitch(es) used and the angle upon which it is based, type of fiber material, and the number of legs if more than one.  On or about February 12, 2013 the safety information provided on a nylon sling was not legible, exposing employees to the hazards of being struck by suspended loads.  Sling was used for lifting pump parts.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 1 instance 10 exposed
Issued
Aug 9, 2013
Penalty
Initial $5,000 · Current $5,000
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  On or about February 12, 2013 the guard was not replaced on the rubber mill, E187, exposing workers to the hazard of being struck by the moving parts of the mill.
Recent events (2)
  • — I (S) $5000
  • — Z (S) $5000

1910.212 A02

Serious Gravity 1 1 instance 10 exposed
Issued
Aug 9, 2013
Abate by
Aug 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(2): Machine guard(s) on machine(s) were so installed that they offered accident hazards in themselves:  On or about February 12, 2013 in the boiler room, for the guard on boiler, E788, the support holding the belt guard was broken.  This caused the guard to slide down and wear on the belts and pulleys that it was guarding, exposing employees to the hazard of being caught in pinch points or struck by broken parts.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 B

Serious Gravity 5 3 instances 19 exposed
Issued
Aug 9, 2013
Abate by
Aug 12, 2013
Penalty
Initial $4,000 · Current $1,000 Reduced
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:    On or about February 12, 2013 drill presses were not anchored exposing workers to the hazards of being struck by or caught in moving parts the machine shop area.      a.  STERLING Model 914 located on workbench near automatic lathe.  b.  Wilton 15" drill press located on floor near back wall.  c.  JET Equipment and tool drill press, Serial #3022135.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $4000

1910.213 G01

Serious Gravity 5 1 instance 10 exposed
Issued
Aug 9, 2013
Abate by
Aug 12, 2013
Penalty
Initial $5,000 · Current $5,000
29 CFR 1910.213(g)(1): Sliding cutoff saw(s) were not provided with an automatically adjusting hood that completely enclosed the upper half of the saw, the arbor end, and the point of operation at all positions of the saw:  On or about February 12, 2013 a job made radial saw did not have a cover over the inside part of the blade.  The saw was located in the packing department and created an amputation hazard to workers cutting gasket materials.
Recent events (2)
  • — I (S) $5000
  • — Z (S) $5000

1910.213 G02

Deleted Serious Gravity 5 1 instance 10 exposed
Issued
Aug 9, 2013
Abate by
Aug 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.213(g)(2): Sliding cutoff saw(s) were not provided with an effective device to return the saw automatically to the back of the table when released at any point of its travel:  On or about February 12, 2013 a job made radial arm cut off saw used to cut gasket materials to a required length was not fitted with a device to automatically return the cutting head to the starting position.  This condition created an amputation hazard to saw operators in the packing department.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.215 B09

Serious Gravity 1 1 instance 7 exposed
Issued
Aug 9, 2013
Abate by
Aug 12, 2013
Penalty
Initial $3,000 · Current $3,000
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  On or about February 12, 2013 the tongue guard on the bench grinder used to sharpen knives in the weaving area of the braiding department had a gap of one inch exposing employees to the hazards of being struck by flying wheel fragments in the event of wheel breakage.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $3000

1910.219 D01

Serious Gravity 5 2 instances 37 exposed
Issued
Aug 9, 2013
Abate by
Aug 12, 2013
Penalty
Initial $5,000 · Current $1,000 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):    On or about February 12, 2013 the following defective belt and pulley guards were found exposing employees to the hazards of being caught in pinch points:    a.  The bottom half of the guard covering the drive belts and pulleys of a lathe was missing located in the shop area.  b.  Back side of Vapor Corporation VA-Power Steam Generator Unit #E788, Model HS2-4626-VHK, S/N 21342, showing exposed belts and pulleys located in the boiler room.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $5000

1910.219 E03 I

Serious Gravity 5 2 instances 16 exposed
Issued
Aug 9, 2013
Abate by
Aug 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o):  On or about February 12, 2013 the following defective belt and pulley guards were found exposing employees to the hazards of being caught in pinch points: a.  The bottom half of the guard covering the drive belts and pulleys of a lathe was missing located in the shop area. b.  Back side of Vapor Corporation VA-Power Steam Generator Unit #E788, Model HS2-4626-VHK, S/N 21342, showing exposed belts and pulleys located in the boiler room.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.242 A

Serious Gravity 1 1 instance 11 exposed
Issued
Aug 9, 2013
Abate by
Aug 12, 2013
Penalty
Initial $3,000 · Current $500 Reduced
29 CFR 1910.242(a): Hand and portable powered tools or equipment were not kept in safe condition:    On or about February 12, 2013 a shop hammer, pry bar and rods used to punch out pins were found with mushroomed heads exposing employees to the hazards of being struck flying metal fragments.  The tools were located in the molding department found in the plastics extrusion building.
Recent events (2)
  • — I (S) $500
  • — Z (S) $3000

1910.242 B

Serious Gravity 5 5 instances 243 exposed
Issued
Aug 9, 2013
Abate by
Aug 12, 2013
Penalty
Initial $4,000 · Current $4,000
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:  On or about February 14, 2013, compressed air near or above 100 psi compressed was widely used for cleaning, exposing employees to the hazards of being struck by high pressure air and fragments.  This was also a fire hazard as many of the chemicals being mixed have the warning:  "Avoid dispersion of dust to reduce fire and explosion potential."    a.  100 psi measured by press used to release gasket from mold, located in press department. b.  80 psi measured in rubber lab used to remove dust. c.  110 psi measured in cryogenic room used to blow dust off clothes. d.  100 psi measured at press E0387 used to clean and remove pieces located in press dept.   e.  90 to 115 psi measured in mixing department used to blowing powdered components down mixer.
Recent events (2)
  • — I (S) $4000
  • — Z (S) $4000

1910.303 B02

Serious Gravity 1 4 instances 29 exposed
Issued
Aug 9, 2013
Abate by
Aug 12, 2013
Penalty
Initial $3,000 · Current $3,000
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  On or about February 12, 2013 electrical boxes designed to be fixed to a permanent structure were used as job made flexible temporary wiring at the establishment and portable power strips were attached to a condiuit for use as permanent wiring.  This condition created an electrical and fire hazard.  a.  Two receptacle job made portable outlet with a black cord, located in the rubber extruding area.  It was on Unit #E66 calender. b.  Job made duplex outlet cord used to power a fan, located in the braiding department. c.  Phillips 110 volt power strip used to energize computers located in the preform area. d.  Phillips 110 volt power strips used to energize computers, located in the rubber Extruding area.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $3000

1910.303 B01 V

Deleted Serious Gravity 5 1 instance 10 exposed
Issued
Aug 9, 2013
Abate by
Aug 12, 2013
Penalty
Initial $5,000 · Current $0 Reduced
29 CFR 1910.303(b)(1)(v): Safety of equipment was not deterined using the consideration of heating effects under all conditions of use:  On or about February 12, 2013, aluminum tape was used to keep employees from turning circuits off in the rubber mill area.  This exposed employees to an electrical and fire hazard in that circuit breakers are not designed to be used as switches.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5000

1910.303 F02

Serious Gravity 1 1 instance 3 exposed
Issued
Aug 9, 2013
Abate by
Aug 12, 2013
Penalty
Initial $0 · Current $1,000
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:    On or about February 12, 2013 electrical circuits were not identified in a 110 volt electrical panel located in the research area.  This condition created an electrical and fire hazard to employees.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $0

1910.303 G01

Serious Gravity 5 2 instances 20 exposed
Issued
Aug 9, 2013
Abate by
Aug 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  On or about February 12, 2013, the areas around electrical equipment was not kept clear creating an electrical and fire hazard at the establishment.  a.  Materials in cardboard barrels was stored in front of Purkell Mixed disconnect and starter, located in the high tech mixing area. b.  Overhead transformer was blocked by chain to light fixture, located in shipping department.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.304 G05

Serious Gravity 5 6 instances 243 exposed
Issued
Aug 9, 2013
Penalty
Initial $5,000 · Current $2,000 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:    On or about February 12 and 13, 2013, the lack of equipment grounding conductors in the following areas exposed employees to an electrical and fire hazard.    a.  Temporary light attached to scales, located in the mixing mezzanine area.  b.  EZGO battery charger plug had a missing ground prong, located in the braiding area.  c.  Zhongshuan, model FS-75, pedestal fan, located in the molding area found in the plastic extrusion building.  d.  Aloha Breeze fan, located in metal prep area.  e.  3 x 110 volt duplex outlet were not grounded, located in the boiler room.  f.  110 volt dupelx electrical outlet, located outside of braiding department in the water pit recovery area.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $5000

1910.305 G01 I

Serious Gravity 5 1 instance 17 exposed
Issued
Aug 9, 2013
Abate by
Aug 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(i): Flexible cords and cables were not approved or conditions of use and location:  On or about February 13, 2013 SPT-2 Cord was used at the establishment creating an electrical and fire hazard located in the metal prep area.  SPT-2 cords are designed for household use and do not have a ground.  This cord provided power to a light on the workbench.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 A02 IX

Serious Gravity 1 3 instances 22 exposed
Issued
Aug 9, 2013
Penalty
Initial $3,000 · Current $3,000
29 CFR 1910.305(a)(2)(ix): All lamps for general illumination were not protected from accidental contact or breakage by a suitable fixture or lamp holder with a guard. Brass shell, paper-lined sockets, or other metal-cased sockets may not be used unless the shell is grounded.  a.  On or about February 12, clip on light used to read scales, located in the rubber mill area, near hazardous chemical storage in the area, presenting a fire hazard. b.  On or about February 12,top of cabs of order pickers, Hallowell Hustler Model H-1000, 460 Volts (unprotected lights 110 volts), located in the order picker area. c.  On or about February 12, fluorescent light bulbs in fixture, located in overflow storage area near rubber mill were not protected. Measurement with steel tape: 77 inches above floor, 277 Volts.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $3000

1910.305 A02 X

Serious Gravity 5 5 instances 16 exposed
Issued
Aug 9, 2013
Abate by
Aug 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(a)(2)(x): Flexible cords and cables were not protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points.    On or about February 12, 2013:  Damaged electrical was found at the following locations creating an electrical hazard to workers:  a.  The outer sheath of a yellow, SJTW extension cord energizing a Dayton Model 6K807J motor to a pedestal fan, located in the press department/rubber injection area, near press No. E369. b.  STAK Lift No. E473, Model 15-56, A/N 394069 had a cord on it with damaged outer sheath, located Press department. c.  Big Joe, E113, used to lift molds located in the press department.  Big Joe had a damaged cord at the machine and the plug was damaged. d.   480 volt wires were exposed to damage from the broken conduit that housed them, located on back of the sand blaster box.   e.  220 volt wires were exposed to damage from the broken conduit containing them, located near oven E516, located in the oven curing room.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B01 II

Serious Gravity 5 4 instances 10 exposed
Issued
Aug 9, 2013
Abate by
Aug 12, 2013
Penalty
Initial $5,000 · Current $2,000 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:    On or about February 12, 2013 openings were found in electrical panels creating an electrical and fire hazard to employees:    a. 2 inch knock out on 220 volts panel for Dustkop Stops Dust collection system, located in the Rubber Mill dust collection area.  b. Opening in front of a 480 VAC chiller water pump starter, located on the North wall of the rubber mill area.  c. 1 inch openings on both ends of a 110 Volt duplex outlet under blue cart used to energize fans, located in the Injection Molding, Maxi-Blast Plastic Media Blasting Room.  d. a 2 inch and a 1 inch opening on th sides of high voltage panel 429 located near the autoclave found in the Rubber Extrusion area.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $5000

1910.305 B02 I

Serious Gravity 5 3 instances 22 exposed
Issued
Aug 9, 2013
Abate by
Aug 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:  On or about February 12, 2013, the covers for 220 volt outlets were missing, exposing employees to the hazards of electrical shock and fire.  a.  220 Volt outlet, located in metal prep grinding room. b.  220 Volt outlet, located below Lathe main disconnect, found in the shipping department. c.  110 Volt wall outlet by copier, located in sales office.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 1 4 instances 17 exposed
Issued
Aug 9, 2013
Abate by
Aug 12, 2013
Penalty
Initial $3,000 · Current $3,000
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:  On or about February 12, 2013 strain relief devices were not provided on the following pieces of electrical equipment creating an electrical and fire hazard at the establishment:  a.  A 110 volt EZGO, Serial #0016694, battery charger located in the Braiding department. b.  110 volt job made electrical outlet located on E66 Calender, found in the extruding department. c.  110 volt cord to TRINCO, dry blast , Model 40x40 SL, Serial #7971-4 located in metal prep grinding room. d.  110 volt cord to clean cut saw, located in packing department.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $3000

1910.307 C

Serious Gravity 5 1 instance 10 exposed
Issued
Aug 9, 2013
Abate by
Aug 12, 2013
Penalty
Initial $5,000 · Current $2,000 Reduced
29 CFR 1910.307(c): Equipment, wiring methods, and installations of equipment in hazardous (classified) locations were not intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location:    On or about February 12, 2013 the conduits attached to the intrinsically safe switches did not have seals to limit volume and to prevent an explosion from traveling throughout the conduit system.  The equipment was located in a room where flammable paints were left to dry with their lids open, exposing employees to the hazards of fire and explosion.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $5000

1910.335 B01

Serious Gravity 5 4 instances 16 exposed
Issued
Aug 9, 2013
Abate by
Aug 12, 2013
Penalty
Initial $4,000 · Current $4,000
29 CFR 1910.335(b)(1): Safety signs, safety symbols, or accident prevention tags were not used where necessary to warn employees about electrical hazards which may endanger them, as required by 1910.145.  On or about February 12, 2013 Warning signs as to the required PPE to protect employees from arc-flash hazards as per NFPA 70E were not posted on the following panels, creating an arc flash hazard.  a.  Panels 231, 432 High voltage, located in the rubber mill area. b.  Disconnect for Purkell Mixer, located in the high tech mixing area. c.  Panel 118 low voltage, located in the shipping department.   d.  480 volt panel 406, located in Maxi-Blast Plastic Media Blasting Room.
Recent events (2)
  • — I (S) $4000
  • — Z (S) $4000

1910.304 A02

Other-than-serious 1 instance 10 exposed
Issued
Aug 9, 2013
Abate by
Aug 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.304(a)(2): Grounded conductors were attached to terminals or leads so as to reverse designated polarity:  On or about February 13, 2013 a 110 volt outlet was wired as to reverse polarity.  The outlet was located in the shipping department storage mezzanine and created an electrical and fire hazard to employees.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Utex Industries, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338908569.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.