Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: STRUCTURAL COMPONENT SYSTEMS, INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of STRUCTURAL COMPONENT SYSTEMS, INC in 1255 FRONT STREET, FREMONT, NE 68025 (NAICS 321214). OSHA activity number 338908841.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Structural Component Systems, INC — free Get an email when a new federal OSHA severe-injury report for Structural Component Systems, INC is published. One employer, no account, unsubscribe in one click.
Site address
1255 FRONT STREET
City
FREMONT
State
NE
ZIP
68025
Mailing
1255 FRONT STREET, FREMONT, NE 68025
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321214
Employees
168
Ownership type
A

3 citations on file for this inspection.

1910.178 A06

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 15, 2013
Abate by
Apr 28, 2013
Penalty
Initial $2,754 · Current $1,500 Reduced
29 CFR 1910.178(a)(6): The user shall see that all nameplates and markings are in place and are maintained in a legible condition.    Job site located at 1255 Front Street, Fremont, NE 68025-The employer had forklift #332 being used by employees where the information plate was not legible.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2754

1910.303 F

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Apr 15, 2013
Abate by
Apr 28, 2013
Penalty
Initial $2,754 · Current $0 Reduced
29 CFR 1910.303(f): Each disconnecting means for motors and appliances was not located and arranged so the purpose was evident, nor legibly marked to indicate its purpose:(a) (LOCATION) (IDENTIFY EQUIPMENT) (STATE HAZARD(S) TO EMPLOYEE(S))  Job site located at 1255 Front Street, Fremont, NE 68025-Electrical panel located in the facility did not have all of the breakers in the panel legibly marked to identify their purpose.  Breakers 21, 23 and 24 were not marked to identify their purpose at the facility.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2754

1904.32 B05

Other-than-serious 1168 instances 168 exposed
Issued
Apr 15, 2013
Abate by
Apr 28, 2013
Penalty
Initial $0 · Current $0
29 CFR 1904.32(b)(5): How do I post the annual summary? You must post a copy of the annual summary in each establishment in a conspicuous place or places where notices to employees are customarily posted. You must ensure that the posted annual summary is not altered, defaced or covered by other material.   Job site located at 1255 Front Street, Fremont, NE 68025-The employer did not post the OSHA 300A at the facility from February 1 through April 30.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Structural Component Systems, INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338908841.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.