OSHA Inspection: SHOOT STRAIGHT CLEARWATER, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of SHOOT STRAIGHT CLEARWATER, INC. in 12000 US HIGHWAY 19 N, CLEARWATER, FL 33764 (NAICS 713990). OSHA activity number 338910243.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Shoot Straight Clearwater, INC. — free Get an email when a new federal OSHA severe-injury report for Shoot Straight Clearwater, INC. is published. One employer, no account, unsubscribe in one click.
Site address
12000 US HIGHWAY 19 N
City
CLEARWATER
State
FL
ZIP
33764
Mailing
12000 US HIGHWAY 19 N, CLEARWATER, FL 33764
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
713990
Employees
25
Ownership type
A

6 citations on file for this inspection.

1910.134 F06

Other-than-serious 2 instances 2 exposed
Issued
May 14, 2013
Abate by
Jul 1, 2013
Penalty
Initial $4,000 · Current $1,500 Reduced
29 CFR 1910.134(f)(6): Qualitative fit tests were performed on negative pressure air-purifying respirators when the required fit factor was greater than 100:     a)  for the 2 employees replacing the baffle filters of the ventilation system located at 12000 US Hwy 19 N, Clearwater (FL), required to wear a MSA Advantage full face respirator with GME-P100 cartridges, as observed on or about 02/28/2013.  In that employee 1 was exposed to 4600 ug/m3 of Lead over a 21 minute time period.  This is equivalent to an 8-hour TWA exposure of 201 ug/m3, which represent 4.02 times the OSHA-PEL of 50 ug/m3.  Employee 2 was exposed to 6800 ug/m3 of Lead over a 23 minute time period.  This is equivalent to an 8-hour TWA exposure of 326 ug/m3, which represent 6.52 times the OSHA-PEL of 50 ug/m3.
Recent events (2)
  • — I (O) $1500
  • — Z (S) $4000

1910.1025 C01

Other-than-serious 2 instances 2 exposed
Issued
May 14, 2013
Abate by
Nov 7, 2013
Penalty
Initial $4,000 · Current $1,500 Reduced

Hazardous substances 1591

29 CFR 1910.1025(c)(1): The employer shall assure that no employee is exposed to lead at concentrations greater than fifty micrograms per cubic meter of air (50 ug/m(3)) averaged over an 8-hour period.      a) On or about 02/28/13, the employee 1 changing the baffle filter of the ventilation system was exposed to lead-in-air at a 8-hour time weighted average of 201 ug/m3 which is approximately 4 times the adjusted permissible exposure limit of 50 ug/m3 for an 8-hour work shift.  The exposure level was derived from a sample collected on February 28, 2013 during  21 minutes of sampling period.  The exposure calculation includes a zero exposure for the 459 minutes not sampled during the 8hr work shift.     b) On or about 02/28/13, the employee 2 changing the baffle filter of the ventilation system was exposed to lead-in-air at a 8-hour time weighted average of 326 ug/m3 which is approximately 6.8 times the adjusted permissible exposure limit of 50 ug/m3 for an 8-hour work shift.  The exposure level was derived from a sample collected on February 28, 2013 during 23 minutes of sampling period.  The exposure calculation includes a zero exposure for the 457 minutes not sampled during the 8hr work shift.
Recent events (2)
  • — I (O) $1500
  • — Z (S) $4000

1910.1025 E01 II

Other-than-serious 1 instance 2 exposed
Issued
May 14, 2013
Abate by
Sep 14, 2013
Penalty
Initial $0 · Current $0

Hazardous substances 1591

29 CFR 1910.1025(e)(1)(ii): For any employee who is exosed to lead above the permissible exposure limit for 30 days or less per year, the employer did not implement engineering controls to reduce the exposure to 200 micrograms per cubic meter:    At facility located at 12000 US. Hwy 19 N. in Clearwater, FL 33764: The employer did not implement any engineering/work practice controls to reduce the exposure to Lead.     a) On or about 02/28/13, the employee 1 changing the baffle filter of the ventilation system was exposed to lead-in-air of 4600 ug/m3 of Lead over a 21 time period; this is equivalent to an 8-hour time weighted average of 201 ug/m3 which is approximately 4 times the adjusted permissible exposure limit of 50 ug/m3 for an 8-hour work shift.  The exposure level was derived from a sample collected on February 28, 2013.  The exposure calculation includes a zero exposure for the 459 minutes not sampled during the 8hr work shift.      b) On or about 02/28/13, the employee 2 changing the baffle filter of the ventilation system was exposed to lead-in-air of 6800 ug/m3 of Lead over a 23 minute time period;  this is equivalent to an 8-hour time weighted average of 326 ug/m3 which is approximately 6.8 times the adjusted permissible exposure limit of 50 ug/m3 for an 8-hour work shift.  The exposure level was derived from a sample collected on February 28, 2013.  The exposure calculation includes a zero exposure for the 457 minutes not sampled during the 8hr work shift.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.1025 E05

Other-than-serious 1 instance 2 exposed
Issued
May 14, 2013
Abate by
Jul 1, 2013
Penalty
Initial $0 · Current $0

Hazardous substances 1591

29 CFR 1910.1025(e)(5): Administrative controls were used as a means of reducing employees time weighted average exposures to lead and the employer did not establish and implement a job rotation schedule which included the required elements:    a) At facility located at 12000 US Hwy 19. N in Clearwater, FL.  Employer did not implement an adequate job rotation schedule that includes the following required items:     1. Name or identification number of each affected employee;  2. Duration and exposure levels at each job or work station where each affected employee is located;  3. Any other information which may be useful in assessing the reliability of administrative controls to reduce exposure to lead.    Employee 1 was exposed to 4600 ug/m3 of Lead over a 21 time period.  This is equivalent to an 8-hour TWA exposure of 201 ug/m3, which represent 4.02% of the OSHA-PEL of 50 ug/m3.  Employee 2 was exposed to 6800 ug/m3 of Lead over a 23 minute time period.  This is equivalent to an 8-hour TWA exposure of 326 ug/m3, which represent 6.52% of the OSHA-PEL of 50 ug/m3.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.1025 D02

Other-than-serious 1 instance 2 exposed
Issued
May 14, 2013
Abate by
Jul 23, 2013
Penalty
Initial $4,000 · Current $1,500 Reduced

Hazardous substances 1591

29 CFR 1910.1025(d)(2): Initial determination. Each employer who has a workplace or work operation covered by this standard shall determine if any employee may be exposed to lead at or above the action level.     a)  Facility Located at 12000 US Hwy in Clearwater, Florida:  Employer did not conduct an initial exposure monitoring for Lead when employees are changing the baffle filters for the ventilation system.  Employee 1 was exposed to 4600 ug/m3 of Lead over a 21 time period; this is equivalent to an 8-hour TWA exposure of 201 ug/m3, which represent 4 times of the OSHA-PEL of 50 ug/m3.  Employee 2 was exposed to 6800 ug/m3 of Lead over a 23 minute time period.  This is equivalent to an 8-hour TWA exposure of 326 ug/m3, which represent 6.52 times the OSHA-PEL of 50 ug/m3.
Recent events (2)
  • — I (O) $1500
  • — Z (S) $4000

1910.1025 H01

Other-than-serious 2 instances 1 exposed
Issued
May 14, 2013
Abate by
Jul 1, 2013
Penalty
Initial $3,000 · Current $1,500 Reduced

Hazardous substances 1591

29 CFR 1910.1025(h)(1): Surfaces. All surfaces shall be maintained as free as practicable of accumulations of lead.    Facility located at 12000 US Hwy 19 N. in Clearwater Florida:  Employer did not maintain surfaces as free of Lead as practicable.  Employees are exposed to Lead accumulations on work surfaces.    a) On or about 02/20/13, Lead accumulations of 4.1935 ug were found on an area of 100 cm2 over the range master desk using the wipe sampling method.    b) On or about 02/20/13, Lead accumulations of 3.7160 ug were found on an area of 100 cm2 around the locker room door handle using the wipe sampling method.
Recent events (2)
  • — I (O) $1500
  • — Z (S) $3000

View Shoot Straight Clearwater, INC.'s full OSHA safety record →