Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: BCW FOOD PRODUCTS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of BCW FOOD PRODUCTS, INC. in 6000 DENTON DRIVE, DALLAS, TX 75235 (NAICS 311211). OSHA activity number 338910466.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch BCW Food Products, INC. for free Get an email when a new federal OSHA severe-injury report for BCW Food Products, INC. is published. One employer, no account, unsubscribe in one click.
Site address
6000 DENTON DRIVE
City
DALLAS
State
TX
ZIP
75235
Mailing
6000 DENTON DRIVE, DALLAS, TX 75235
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311211
Employees
55
Ownership type
A

3 citations on file for this inspection.

1910.147 C07 I

Serious Gravity 10 1 instance 2 exposed
Issued
Aug 2, 2013
Abate by
Aug 16, 2013
Penalty
Initial $5,390 · Current $7,000
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program were understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls were acquired by employees:    The employer does not ensure that employees understand the purpose and function of the energy control program, and that they have acquired the knowledge and skills required for the safe application, usage, and removal of the energy controls. This violation was discovered in the small pack production area where the employer did not ensure that at least two (2) employees, who were performing a changeover cleanout on February 4, 2013 and February 5, 2013, understood the purpose and function of the energy control program, and that they had acquired the knowledge and skills required for the safe application, usage and removal of the energy controls.
Recent events (3)
  • · F (S) $7000
  • · C (S) $5390
  • · Z (S) $5390

1910.147 D04 I

Serious Gravity 10 1 instance 2 exposed
Issued
Aug 2, 2013
Abate by
Aug 7, 2013
Penalty
Initial $53,900 · Current $7,000 Reduced
29 CFR 1910.147 (d)(4)(i): Lockout or tagout devices were not affixed to each energy-isolating device by authorized employees:      The employer does not ensure that lockout / tagout devices are affixed to each energy-isolating device by authorized employees. This violation occurred on February 4, 2013 and February 5, 2013, in the small pack production area; where at least two (2) authorized employees, who were performing a changeover cleanout, did not affix a lockout or tagout device to each energy-isolating device.
Recent events (3)
  • · F (S) $7000
  • · C (W) $53900
  • · Z (W) $53900

1910.147 C05 II D

Repeat Gravity 5 2 instances 1 exposed
Issued
Aug 2, 2013
Abate by
Aug 7, 2013
Penalty
Initial $7,700 · Current $50,000
29 CFR 1910.147 (c)(5)(ii)(D): Lockout devices and tagout devices did not indicate the identity of the employee who applied the device(s):      The employer does not ensure that each lockout device identifies the employee who applied the device. This violation was observed on February 8, 2013, in the small pack production area; where at least two (2) of the four (4) locks that were applied to the electric and pneumatic disconnects by employees, who were sanitizing the screw conveyor, did not identify the employee who had applied the locks.         BCW FOOD PRODUCTS, INC. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD, 29 CFR 1910.147(c)(5)(ii)(D), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 462779, CITATION NUMBER 001, ITEM NUMBER 005, ISSUED ON NOVEMBER 28, 2012 AND WAS AFFIRMED FINAL ORDER ON DECEMBER 19, 2012, WITH RESPECT TO A WORKPLACE LOCATED AT 6000 DENTON DRIVE, DALLAS, TEXAS 75235.
Recent events (3)
  • · F (R) $50000
  • · C (R) $7700
  • · Z (R) $7700

View BCW Food Products, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338910466.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.