Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: BISON DRILLING AND FIELD SERVICE

Programmed Related inspection · Safety discipline

On , OSHA opened a programmed Related safety inspection of BISON DRILLING AND FIELD SERVICE in 23.7 MILES SE FORT STOCKTON RIG # 75 (LEASE TO BERKELY STATE WELL# 4612), FORT STOCKTON, TX 79735 (NAICS 213111). OSHA activity number 338910672.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bison Drilling and Field Service for free Get an email when a new federal OSHA severe-injury report for Bison Drilling and Field Service is published. One employer, no account, unsubscribe in one click.
Site address
23.7 MILES SE FORT STOCKTON RIG # 75 (LEASE TO BERKELY STATE WELL# 4612)
City
FORT STOCKTON
State
TX
ZIP
79735
Mailing
P.O. BOX 61727, MIDLAND, TX 79711
Inspection type
Programmed Related (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213111
Employees
22
Ownership type
Private (A)

4 citations on file for this inspection.

1910.151 C

Serious Gravity 5 1 instance 6 exposed
Issued
May 22, 2013
Abate by
Jun 4, 2013
Penalty
Initial $3,600 · Current $2,500 Reduced
29 CFR 1910.151(c): Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use.  On or about February 12, 2013, and times prior, employees were exposed to hazardous chemicals at the mud house and no eyewash or drenching facilities were provided.  This condition exposed employees to safety hazards.
Recent events (2)
  • · I (S) $2500
  • · Z (S) $3600

1910.1200 G01

Serious Gravity 1 1 instance 6 exposed
Issued
May 22, 2013
Abate by
Jun 4, 2013
Penalty
Initial $2,700 · Current $1,500 Reduced
29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use.    On or about February 12, 2013, and times prior hereto, employer did not have the safety data sheet for Formosa-P Caustic Soda, chemical used in the workplace. This condition exposed employees to potential safety and health hazards.
Recent events (2)
  • · I (S) $1500
  • · Z (S) $2700

1910.157 C04

Repeat 1 instance 6 exposed
Issued
May 22, 2013
Abate by
Jun 4, 2013
Penalty
Initial $1,800 · Current $900 Reduced
29 CFR 1910.157(c)(4): The employer did not assure that portable fire extinguishers are maintained in a fully charged and operable condition and kept in their designated places at all times except during use.  On or about February 12, 2013, and times prior, a portable carbon dioxide fire extinguisher located in the generator house was not charged and ready for use.  This condition exposed employees to potential fire hazards.    Bison Drilling & Field Services, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.157(c)(4) which was contained in OSHA inspection number 315714659, citation number 2, item 1, and was affirmed as a final order on 07-26-2012, with respect to a workplace located at 8.8 Miles NW of Midland, TX 79707.
Recent events (2)
  • · I (R) $900
  • · Z (R) $1800

1910.305 B03 II

Other-than-serious 1 instance 6 exposed
Issued
May 22, 2013
Abate by
Jun 4, 2013
Penalty
Initial $90 · Current $100
29 CFR 1910.305(b)(3)(ii): Boxes shall be closed by suitable covers securely fastened in place.  On or about February 12, 2013, and times prior, an electrical box cover was not securely fastened in place. This condition exposed employees to electrical safety hazards.
Recent events (2)
  • · I (O) $100
  • · Z (O) $90

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 338910672.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.