Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,288Inspections Most recent open 2026-07-24 Last loaded 2026-07-29

OSHA Inspection: IFCO SYSTEMS US, LLC SITE146

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of IFCO SYSTEMS US, LLC SITE146 in 13001 N.E. 29TH AVENUE, AMARILLO, TX 79111 (NAICS 321920). OSHA activity number 338911100.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ifco Systems US, LLC Site146 — free Get an email when a new federal OSHA severe-injury report for Ifco Systems US, LLC Site146 is published. One employer, no account, unsubscribe in one click.
Site address
13001 N.E. 29TH AVENUE
City
AMARILLO
State
TX
ZIP
79111
Mailing
13001 N.E. 29TH, AMARILLO, TX 79111
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321920
Employees
28
Ownership type
A

10 citations on file for this inspection.

1910.22 A01

Serious Gravity 10 1 instance 12 exposed
Issued
Jul 26, 2013
Abate by
Aug 7, 2013
Penalty
Initial $5,390 · Current $3,773 Reduced
29 CFR 1910.22(a)(1):  All places of employment, passageways, storerooms, and service rooms were not kept clean and orderly and in a sanitary condition:    On February 14, 2013, at the IFCO Systems North America site 146 located at 13001 NE. 29th Avenue, Amarillo, Texas 79111.  The employer failed to ensure that the work place was kept in an orderly manner each day exposing employees to deflagration or fire hazard:     a)  New pallet shop area.    b)  New pallet shop area in and around the saws.    c)  Accumlated saw dust in attached building north of new pallet shop.
Recent events (2)
  • — I (S) $3773
  • — Z (S) $5390

1910.22 A02

Deleted Serious Gravity 5 1 instance 12 exposed
Issued
Jul 26, 2013
Abate by
Aug 7, 2013
Penalty
Initial $3,080 · Current $0 Reduced
29 CFR 1910.22(a)(2):  The floor of every workroom was not maintained in a clean and, so far as possible, a dry condition:  On February 14, 2012, at IFCO Systems North America, Inc. Site 146, located at 13001 NE 29th Avenue, Amarillo, Texas 79111.  Employer did not ensure the floor in the New Pallet Shop was maintained in dry condition.  Employees were exposed to slips/trips/falls.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3080

1910.178 C02 VI A

Serious Gravity 5 1 instance 28 exposed
Issued
Jul 26, 2013
Abate by
Nov 19, 2013
Penalty
Initial $3,080 · Current $2,156 Reduced
29 CFR 1910.178(c)(2)(vi)(a):  Only approved power operated industrial trucks designated as EX were to be used in atmospheres in which combustible dust was suspension continuously, intermittently, or periodically under normal operating conditions, in quantities sufficient to produce explosive or ignitable mixtures, or where mechanical failure or abnormal operation of machinery or equipment might cause such mixtures to be produced:    On February 14, 2013, at IFCO Systems North America Site 146, located at 13001 NE 29th Avenue, Amarillo, Texas 79111.  Employer did not ensure the powered industiral trucks used in and out of the new pallet shop were safe to operate in the environment.  Exposiing employees to burn hazards.
Recent events (2)
  • — I (S) $2156
  • — Z (S) $3080

1910.213 S01

Serious Gravity 10 1 instance 15 exposed
Issued
Jul 26, 2013
Abate by
Aug 7, 2013
Penalty
Initial $5,390 · Current $3,773 Reduced
29 CFR 1910.213(s)(1):  Dull, badly set, improperly filed, or improperly tensioned saws were not immediately removed from service, before they begin to cause the material to stick, jam, or kick back when it is fed to the saw at normal speed:    On February 14, 2013, at the IFCO Systems North America site #146, located at 13001 NE 29th Avenue, Amarillo, Texas 79111.  The KM-16 multie trimmer saw was not taken out of service from improper pressure guide rods on saw which caused claws not to synconizing causing wood to shot out of back of saw during operations.  Exposing employee to caught-by or struck-by hazards.
Recent events (2)
  • — I (S) $3773
  • — Z (S) $5390

1910.303 F02

Serious Gravity 5 1 instance 6 exposed
Issued
Jul 26, 2013
Abate by
Aug 7, 2013
Penalty
Initial $3,080 · Current $2,156 Reduced
29 CFR 1910.303(f)(2):   Services, feeders, and branch circuits.  Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, were not legibly marked to indicate its purpose, unless located and arranged so the purpose is evident:    On February 14, 2013, at IFCO Systems North America Site 146, located at 13001 NE. 29th Avenue, Amarillo,Texas 79111.  The employer did not ensure the junction box in the pallet refurbishing shop was labeled or properly labeled for their purpose.  Exposing employees to electric shock or burns.
Recent events (2)
  • — I (S) $2156
  • — Z (S) $3080

1910.305 B03 II

Serious Gravity 5 1 instance 6 exposed
Issued
Jul 26, 2013
Abate by
Aug 7, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(3)(ii):  Pull and junction boxes used on systems rated over 600 volts, nominal, were not closed by suitable covers, securely fastened in place:  On February 14, 2013, at the IFCO Systems North America located at 13001 NE. 29th Avenue, Amarillo, Texas 79111.  The employer did not ensure that a junction box was closed with a cover on the west wall of the pallet refurbishing.    Exposing employees to electrical shock/burns/electrocution hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.307 B

Serious Gravity 5 1 instance 28 exposed
Issued
Jul 26, 2013
Abate by
Aug 7, 2013
Penalty
Initial $3,080 · Current $2,156 Reduced
29 CFR 1910.307(b):  All areas designated as hazardous locations under the Class and Zone system and areas designated under the Class and Division system were not properly documented. Documentation was not available to those authorized to design, install, inspect, maintain, or operate electric equipment at the location:    On February 14, 2013, at IFCO Systems North America site #146, located at 13001 NE 29th Avenue, Amarillo, Texas 79111.  The employer did not make available documentation to the electricians, maintenance or employees operating equipment in facility.  Exposing employees to explosion, deflagration or fire hazards.
Recent events (2)
  • — I (S) $2156
  • — Z (S) $3080

1910.307 C01

Serious Gravity 10 1 instance 18 exposed
Issued
Jul 26, 2013
Abate by
Dec 19, 2013
Penalty
Initial $5,390 · Current $3,773 Reduced
29 CFR 1910.307(c)(1):   The employer did not ensure the equipment and wiring used in facility was intrinsically safe or was permitted in a hazardous location for which it is approved:    On February 14, 2013, at the IFCO Systems North America Site 146, located at 13001 NE 29th Avenue, Amarillo, Texas 79111.  The employer did not ensure the electrical wiring in building and electrical equipment and hand tools used for remove of dust and debris were intrinsically safe.  Exposing employees to explosion, deflagration or fire hazards.
Recent events (2)
  • — I (S) $3773
  • — Z (S) $5390

1910.1200 E01

Other-than-serious 1 instance 28 exposed
Issued
Jul 26, 2013
Abate by
Sep 19, 2013
Penalty
Initial $3,080 · Current $1,000 Reduced
29 CFR 1910.1200(e)(1):  The employer had not developed, implemented, and or maintained at the workplace a written hazard communication program which describes how the criteria in 29 CFR 1910.1200 (f), (g), and (h) will be met:      On February 14, 2013, and at times prior thereto, at the business located at 13001 NE 29th Avenue, Amarillo, Texas 79111.  The employer had not developed a written hazardous communication program.  The employees were exposed to explosion, deflagration or fire hazards.
Recent events (2)
  • — I (O) $1000
  • — Z (S) $3080

1910.22 A02

Repeat Gravity 5 1 instance 3 exposed
Issued
Jul 26, 2013
Abate by
Nov 19, 2013
Penalty
Initial $6,160 · Current $4,312 Reduced
29 CFR 1910.22(a)(2):  Floor(s) of workroom(s) were not maintained in a clean and, so far as possible, a dry condition:      On February 14, 2013, at the IFCO Systems North America Site 146 located at 13001 NE 29th Avenue, Amarillo, Texas 79111, employees were exposed to a slip hazrd when working with wet floors from a leaking roof in Production areas.    a.  New pallet shop southeast corner by the Quincy compressor and trim track saw.    b.  New pallet shop southwest corner by the band saw.    IFCO Systems, was previously cited for a violation of this Occupational Safety and Health Standard or its equivalent standard 29 CFR 1910.22(a)(2), which was contained in OSHA Inspection Number 312855745 Citation 01 Item 001, issued on 03/19/2010 and became a final order on 04/14/2010.
Recent events (2)
  • — I (R) $4312
  • — Z (R) $6160

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338911100.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.