Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MILSCO MANUFACTURING CO

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of MILSCO MANUFACTURING CO in 1094 SUPERIOR WAY, THOMSON, GA 30824 (NAICS 326150). OSHA activity number 338911605.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Milsco Manufacturing CO — free Get an email when a new federal OSHA severe-injury report for Milsco Manufacturing CO is published. One employer, no account, unsubscribe in one click.
Site address
1094 SUPERIOR WAY
City
THOMSON
State
GA
ZIP
30824
Mailing
1094 SUPERIOR WAY, THOMSON, GA 30824
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326150
Employees
67
Ownership type
A

4 citations on file for this inspection.

1910.147 C07 I A

Serious Gravity 10 3 instances 3 exposed
Issued
Mar 12, 2013
Abate by
Apr 26, 2013
Penalty
Initial $7,000 · Current $3,500 Reduced
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.  On or about 02/19/13 at Thomson, GA: Employees were exposed to struck-by, caught between, and electrical hazards while maintaining and servicing company equipment and facilities.  The employer failed to ensure that all authorized employees have received lockout tagout training.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $7000

1910.147 C07 I B

Serious Gravity 10 3 instances 3 exposed
Issued
Mar 12, 2013
Abate by
Apr 26, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i)(B): Affected employees were not instructed in the purpose and use of the energy control procedure:  On or about 02/19/13 at Thomson, GA: Employees were exposed to struck-by, caught between, and electrical hazards while operating machines and equipment at the production facility.  The employer failed to ensure that all affected employees received lockout tagout training.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.332 B01

Serious Gravity 10 2 instances 2 exposed
Issued
Mar 12, 2013
Abate by
Apr 26, 2013
Penalty
Initial $7,000 · Current $3,500 Reduced
29 CFR 1910.332(b)(1): All maintenance employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments:  On or about 02/19/13 at Thomson, GA: Employees were exposed to electrical hazards while performing work on the company's equipment and facilities.  The employer has no record of training for maintenance employees, who perform electrical work on the company's equipment and facilities (120/240/480 Volt).
Recent events (2)
  • — I (S) $3500
  • — Z (S) $7000

1910.335 A01 I

Serious Gravity 10 1 instance 2 exposed
Issued
Mar 12, 2013
Abate by
Apr 26, 2013
Penalty
Initial $7,000 · Current $3,500 Reduced
29 CFR 1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not provided with electrical protective equipment that was appropriate for the specific parts of the body that needed to be protected and for the work being performed:    On or about 02/19/13 at Thomson, GA: Employees are exposed to electrical hazards while performing electrical work on production and facility equipment.  The employer failed to provide qualified persons with appropriate electrical related personal protective equipment, when performing electrical work.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $7000

View Milsco Manufacturing CO's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338911605.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.