BROCKTON, MA ·
OSHA Inspection: AGM INDUSTRIES INCORPORATED
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of AGM INDUSTRIES INCORPORATED in 16 JONATHAN DRIVE, BROCKTON, MA 02301 (NAICS 332722). OSHA activity number 338912256.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AGM INDUSTRIES INCORPORATED
- Site address
- 16 JONATHAN DRIVE
- City
- BROCKTON
- State
- MA
- ZIP
- 02301
- Mailing
- 16 JONATHAN DRIVE, BROCKTON, MA 02301
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332722
- Employees
- 23
- Ownership type
- Private (A)
Citations
10 citations on file for this inspection.
1910.147 C04 I
- Issued
- Jul 10, 2013
- Abate by
- Nov 21, 2013
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: Press Dept.: The employer did not develop and utilize lockout tagout procedures while moving the metal stock through the dies of the Perkins Power Press of the #6 Automatic Line. A worker crushed a finger.
Recent events (3)
- · F (S) $1680
- · C (S) $2800
- · Z (S) $2800
1910.147 C06 I B
- Issued
- Jul 10, 2013
- Abate by
- May 30, 2014
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i)(B): The periodic inspection shall be conducted to correct any deviations or inadequacies identified with the lockout tagout procedures: Press Dept.: The lockout tagout procedures for the Perkins Power Press of the #6 Automatic Line were not revised after the guarding of the press changed. A worker crushed a finger.
Recent events (3)
- · F (S) $0
- · C (S) $2800
- · Z (S) $2800
1910.147 C07 I
- Issued
- Jul 10, 2013
- Abate by
- May 30, 2014
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: Press Dept.: The employer did not train the operator of the Perkins Power Press of the Automatic 6 Line on the lockout tagout procedures for that machine. A worker crushed a finger.
Recent events (3)
- · F (S) $0
- · C (S) $2800
- · Z (S) $2800
1910.217 B03 I
- Issued
- Jul 10, 2013
- Abate by
- May 30, 2014
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.217(b)(3)(i): Mechanical power press(es) using full revolution clutches did not incorporate a single-stroke mechanism: Press Dept.: The Perkins Power Press of Automatic Line #6 did not have a single stroke mechanism when the operator jogged material through the press during startup. A worker crushed a finger.
Recent events (3)
- · F (S) $1680
- · C (S) $2800
- · Z (S) $2800
1910.217 C02 I A
- Issued
- Jul 10, 2013
- Abate by
- May 30, 2014
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.217(c)(2)(i)(a): Point of operation guards on mechanical power presses did not prevent entry of hands or fingers into the point of operation by reaching through, over, under or around the guards: Press Dept.: Automatic Perkins Power Press #6 was not guarded adequately when the operator advances the stock through the dies. The air is turned off enabling the operator to raise the front side guard. The operator holds in the limit switch for the front side guard with a tool. A worker crushed a finger.
Recent events (3)
- · F (S) $1680
- · C (S) $2800
- · Z (S) $2800
1910.217 C02 VI
- Issued
- Jul 10, 2013
- Abate by
- May 30, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.217(c)(2)(vi): The adjustable barrier guard(s) on mechanical power press(es) were not adjusted or operated in conformity with Table 10 O-10: Press Dept.: The opening created by raising the interlocked guard at the front of the Perkins Power Press of the #6 Automatic Line did not comply with Table O-10. A worker crushed a finger.
Recent events (3)
- · F (S) $0
- · C (S) $0
- · Z (S) $0
1910.217 C02 I F
- Issued
- Jul 10, 2013
- Abate by
- May 30, 2014
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1910.217(c)(2)(i)(f): Point of operation guard(s) on mechanical power press(es) did not offer maximum visibility of the point of operation consistent with other requirements: Press Dept.: The point of operation of the Perkins Power Press was not visible so that the operator had to open the guard while advancing the material through the dies. The worker crushed a finger.
Recent events (3)
- · F (S) $0
- · C (S) $2800
- · Z (S) $2800
1910.217 D01 II
- Issued
- Jul 10, 2013
- Abate by
- May 30, 2014
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.217(d)(1)(ii): Hand tools were not used for freeing and removing stuck work or scrap pieces from the dies of mechanical power presses so that no employee needed to reach into the point of operation for such purposes: Press Dept.: The employer did not enforce the use of hand tools for operators of the Perkins Power Press of Automatic Line #6 when the operator has to position the stock at the slot of the tab forming die. A worker crushed a finger.
Recent events (3)
- · F (S) $1680
- · C (S) $2800
- · Z (S) $2800
1910.217 F02
- Issued
- Jul 10, 2013
- Abate by
- May 30, 2014
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1910.217(f)(2): Operators were not trained and instructed in the safe method of work before starting work on mechanical power presses: Press Dept.: The employer did not did not instruct the press operator of the Perkins Power Press of the #6 Automatic Line on the safe method of operating the press. A worker crushed a finger.
Recent events (3)
- · F (S) $0
- · C (S) $2800
- · Z (S) $2800
1910.217 G
- Issued
- Jul 10, 2013
- Abate by
- Aug 26, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.217(g): The employer did not report within 30 days of the occurrence, to either the Director of the Office of Standards Development OSHA, U.S. Department of Labor: Worksite: The employer did not report a power press accident to OSHA.
Recent events (3)
- · F (O) $0
- · C (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 332722)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 338912256.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.