ROCHESTER, NH —
OSHA Inspection: BT ROOFING
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BT ROOFING in 117 WAKEFIELD STREET, ROCHESTER, NH 03839 (NAICS 238160). OSHA activity number 338912322.
Where did this inspection happen?
- Establishment
- BT ROOFING
- Site address
- 117 WAKEFIELD STREET
- City
- ROCHESTER
- State
- NH
- ZIP
- 03839
- Mailing
- 380 LOWER GUINEA ROAD, LEBANON, ME 04027
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 5
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.451 F15
- Issued
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1926.451(f)(15): Ladders were used on scaffolds to increase the working level height of employees: without satisfying the criteria of subparagraphs (i) - (iv) of this paragraph. (a) Roof - Ladders were used on roof bracket scaffolding.
Recent events (1)
- — Z (S) $2800
1926.501 B13
- Issued
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) Roof - Employees were on a steep roof without fall protection.
Recent events (1)
- — Z (S) $2800
1926.1053 B01
- Issued
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: (a) Roof - The ladder was only extended one foot above the roof eve.
Recent events (1)
- — Z (S) $2800
More inspections at BT ROOFING
STRATHAM, NH—2006-06-10 00:00:00
BT ROOFING
NORTH HAMPTON, NH—2006-03-23 00:00:00
BT ROOFING
INCLINE VILLAGE, NV—2003-05-21 00:00:00
BT ROOFING
View BT ROOFING's full OSHA safety record →
More inspections in this industry (NAICS 238160)
SIOUX FALLS, SD—2026-07-13
H & R ROOFING OF SOUTH DAKOTA, INC.
HENDERSON, NV—2026-07-13
INTEGRITY ROOFING LLC
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CAMDEN, OH—2026-07-13
ALBERTO MORALES
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
More inspections in NH
CONCORD, NH—2026-07-10
C.C. TOMATOES
FRANCESTOWN, NH—2026-07-10
JM BUILDERS LLC
FRANCESTOWN, NH—2026-07-10
D&D INSULATION, LLC
NORTHFIELD, NH—2026-07-03
JP PEST SERVICES
CONCORD, NH—2026-07-01
REYES CARPENTRY, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338912322.