OSHA Inspection: BROWNING ENTERPRISE, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of BROWNING ENTERPRISE, INC. in 100 7TH AVENUE SW, ATTALLA, AL 35954 (NAICS 332999). OSHA activity number 338913510.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Browning Enterprise, INC. — free Get an email when a new federal OSHA severe-injury report for Browning Enterprise, INC. is published. One employer, no account, unsubscribe in one click.
Site address
100 7TH AVENUE SW
City
ATTALLA
State
AL
ZIP
35954
Mailing
P.O. BOX 807, ATTALLA, AL 35954
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
27
Ownership type
A

13 citations on file for this inspection.

1910.110 D10

Serious Gravity 5 1 instance 3 exposed
Issued
May 3, 2013
Penalty
Initial $2,380 · Current $1,428 Reduced
29 CFR 1910.110(d)(10):  Precautions were not taken to prevent damage to LP gas system(s) from vehicular traffic:  (a) On or about February 20, 2013 - Outside of Building #5, a propane gas tank used to heat the building was not protected against impact with moving trucks in the area.
Recent events (2)
  • — I (S) $1428
  • — Z (S) $2380

1910.132 A

Serious Gravity 5 1 instance 1 exposed
Issued
May 3, 2013
Abate by
May 15, 2013
Penalty
Initial $2,975 · Current $1,785 Reduced
29 CFR 1910.132(a):  Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, were not provided, used, and maintained in a sanitary and reliable condition wherever it is necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact:  (a) On or about March 6, 2013 - Building #8, Submerged arc welding machine, an operator standing at approximately 12 inches from the oxygen-acetylene torches was not wearing flame retardant protective clothing for the fire hazard.
Recent events (2)
  • — I (S) $1785
  • — Z (S) $2975

1910.134 I07

Serious Gravity 10 1 instance 2 exposed
Issued
May 3, 2013
Abate by
Jun 7, 2013
Penalty
Initial $4,900 · Current $2,940 Reduced
29 CFR 1910.134(i)(7): Oil lubricated compressor(s) used to supply breathing air did not have a high-temperature or carbon monoxide alarm(s) or both:  (a) On or about March 6, 2013 - Abrasive blasting area, an oil-lubricated compressor used to supply the breathing air for the airline respirators was not provided with a high temperature or carbon monoxide alarm, or both, to monitor levels of carbon monoxide.
Recent events (2)
  • — I (S) $2940
  • — Z (S) $4900

1910.219 F03

Serious Gravity 5 1 instance 2 exposed
Issued
May 3, 2013
Abate by
May 15, 2013
Penalty
Initial $2,380 · Current $1,428 Reduced
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven (7) feet or less above floors or platforms were not enclosed:   (a) On or about February 20, 2013 - Building #9, Cincinnati press brake, left side sprocket wheel and chains located at approximately 2 feet, 6 inches above the floor were not guarded.
Recent events (2)
  • — I (S) $1428
  • — Z (S) $2380

1910.253 B02 IV

Serious Gravity 1 3 instances 3 exposed
Issued
May 3, 2013
Penalty
Initial $1,785 · Current $1,071 Reduced
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use:  (a) On or about February 20, 2013 - Building #4, four oxygen cylinders in storage did not have caps in place.  (b) On or about February 20, 2013 - Building #4, two acetylene cylinders in storage did not have caps in place.  (c) On or about February 20, 2013 - Building #8, one acetylene cylinder in storage did not have a cap in place.
Recent events (2)
  • — I (S) $1071
  • — Z (S) $1785

1910.253 B04 III

Serious Gravity 1 1 instance 2 exposed
Issued
May 3, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour:  (a) On or about February 20, 2013 - Building #8, one oxygen cylinder and one acetylene cylinder were stored together.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.22 A01

Other-than-serious 1 instance 3 exposed
Issued
May 3, 2013
Abate by
May 9, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition:  (a) On or about February 20, 2013 - Building #4, one electrical cord more than 6 feet in length used to connect a heater was lying on the floor creating a tripping hazard.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.132 D02

Other-than-serious 1 instance 27 exposed
Issued
May 3, 2013
Abate by
Jun 7, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.132(d)(2): The employer did not verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated, the person certifying that the evaluation has been performed, the date(s) of the hazard assessment, and, which identifies the document as a certification of hazard assessment:  (a) On or about February 20, 2013 - Facility, no written certification to verify the hazard assessment had been performed.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 C02 I

Other-than-serious 1 instance 10 exposed
Issued
May 3, 2013
Abate by
May 23, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible:  (a) On or about February 20, 2013 - All buildings, employees who used 3M N95 particulate respirators voluntarily were not provided with the information contained in Appendix D of 29 CFR 1910.134.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 F02

Other-than-serious 1 instance 2 exposed
Issued
May 3, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator, whenever a different respirator facepiece (size, style, model or make) was used, and at least annually thereafter:  (a) On or about March 6, 2013 - Facility, painter employees who were required to wear Binks half-face mask respirators were fit tested on 10/22/04 and not fit tested again until 03/29/13.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.157 E02

Other-than-serious 1 instance 6 exposed
Issued
May 3, 2013
Abate by
Jun 7, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:  (a) On or about February 20, 2013 - All buildings, portable fire extinguishers, ABC type, were not visually inspected every month.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G01 IV A

Other-than-serious 1 instance 1 exposed
Issued
May 3, 2013
Abate by
May 15, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  (a) On or about February 20, 2013 - Building #4, vertical saw machine, one electrical cord more than 6 feet in length was used to connect a heater.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1026 D01

Other-than-serious 1 instance 2 exposed
Issued
May 3, 2013
Abate by
Jun 7, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1026(d)(1): The employer with a workplace or work operation covered by this standard did not determine the 8-hour time-weighted average exposure for each employee exposed to chromium (VI):  (a) On or about March 6, 2013 - Building #4, one employee performing welding on stainless steel was exposed to an 8-hour time-weighted average of chromium VI at 0.0004 mg/m3 based upon a 25 minute welding sample collected on 03/06/13.  Zero exposure was assumed for the unsampled period of 455 minutes.   Note: The employer may use these results to meet the initial monitoring requirement.  Additional monitoring is required if there is a change in the production process, raw materials, equipment, personnel, work practices, or control methods that may result in new or additional exposures to chromium (VI).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Browning Enterprise, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338913510.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.